ANOLiS Arcsource 4MC II LED Lighting Installation Guide
ANOLiS Arcsource 4MC II LED Lighting

Warning Icon Fixture must be installed by a qualified electrican in accordance with all national and local electrical and construction codes and regulations.

Product Diagram

CEILING OPENING

CEILING OPENING

Prepare mounting hole with diameter of 65 mm.

CONNECTION

CONNECTION

Pin Function Wire
1 Red + Orange/White
2 Green + Orange
3 Blue + Green/White
4 White – Blue
5 Red – Blue/White
6 Green – Green
7 Blue – Brown/White
8 White – Brown

Power Supply Units suitable for ArcSource MC II:
ArcPower Rack Unit
ArcPower 36/72/144/360

ArcSource 4MC II can be connected directly to power supply unit.
Splitters can be used for connection of multiple fixtures at one output line.
Cable connectors can be used, when extension of output line is required.

CONNECTION

ArcSource 4MC II fixtures connected to ArcPower Rack Unit with use of splitters and cables connector.

LUMINAIRE INSTALLATION

LUMINAIRE INSTALLATION

Lift up spring clips on both sides of the fixture

LUMINAIRE INSTALLATION

Insert the luminaire into the ceiling opening.

LUMINAIRE INSTALLATION

Secure the luminaire inside the ceiling by releasing spring clips.

ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu | www.anolislighting.com