Warning-icon.png The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations. This device falls under class I and must be grounded!Warning-icon.png Anolis ArcPixel Power Controller - POWER CONNECTION

STEP 1
ARCPIXEL POWER INSTALLATION
Warning-icon.png Use fasteners that are appropriate for use with your mounting surface.Warning-icon.png

Anolis ArcPixel Power Controller - POWER CONNECTION 1Fasten the ArcPixel Power to surface via four mounting holes and four screws.
STEP 2
ARCPIXEL POWER CONNECTION
Rear side view – 4x ArcDot output, 4x ArcPix output, Ethernet, DMX OUT and DMX IN
Anolis ArcPixel Power Controller - Rear side viewFront side view – Power InputAnolis ArcPixel Power Controller - Front side viewWarning-icon.png Maximum length between the ArcPixel Power and the last fuxtures must not exceed 100 meters. Do not connect or disconnect LED modules when ArcPixel Power is under voltage. If the line of fixtures is disconnected, switch off the ArcPixel Power before restoring the connection.Warning-icon.png
2A ArcDot connectionAnolis ArcPixel Power Controller - ArcDot connection

ArcDot line may be done with in/out connection or by using T-connectors (1 ArcDot can be connected to T-connector). Max. number of ArcDots per output is 35. Max. cable length of 1 LED output is 65m at 35 ArcDots and 100m at 25 ArcDots per LED output.
At the beginning of each output line a ferrite has to be installed and an active terminator has to be installed at the end of the line for addresiing. Active terminator has to be replaced by passive terminator when addressing is done.
Anolis ArcPixel Power Controller - terminator2B ArcPix II connection
Anolis ArcPixel Power Controller - ArcPix II connection

Ferrite filters application instructions:
The ferrite with one turn of the flat cable around it (aprox. 100mm of cable) has to be placed at the beginning of each ArcPix II output line. Ferrite without cable turn around it has to be placed after each thirtieth ArcPix II of the output line before mounting it to surface. (e.g. total of 4 ferrites in line of 100 ArcPixes II) Every ArcPix II line has to be terminated with the termination box ArcPix.
Install terminal block to flat cable of ArcPix II line and connect it to ArcPixel Power output.
Max. load per output is 100 ArcPixes II and max. length of output line is 100m.Anolis ArcPixel Power Controller - terminator 1

Anolis logoROBE lighting s. r. o.
Palackeho 416
757 01 Valasske Mezirici
Czech Republic
Tel.: +420 571 751 500
E-mail: info@anolis.eu 
www.anolislighting.com
VERSION 2.0 / 2_2023

Documents / Resources

Anolis ArcPixel Power Controller [pdf] Instruction Manual
ArcPixel, ArcPixel Power Controller, Power Controller, Controller
Anolis ArcPixel Power Controller [pdf] User Manual
ArcPixel Power Controller, ArcPixel, Power Controller, Controller

References

Leave a comment

Your email address will not be published. Required fields are marked *