Introduction

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR Eminere ! Save it for future reference.

This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure safe operation, it is absolutely necessary for the user to follow the safety instructions and warnings written in this manual.
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device.
Unauthorized modification will void warranty.

Safety instructions

DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!

This fixture should be operated only from the type of power source indicated on the marking label. If you are not
sure of the type of power supplied, consult your authorized distributor or local power company.
Always disconnect the fixture from AC power before cleaning, servicing or installing.
Make sure the data/power cable is not damaged by sharp edges. Check the fixture and the power cord from time
to time.
Do not install the unit near an open flame.
During operation the housing becomes hot.
Refer servicing to qualified service personnel.

This fixture falls under protection class I.

Therefore this fixture has to be connected to a mains socket outlet with a protective earthing connection.

Do not connect this fixture to a dimmer pack.

LED light emission. Risk of eye injury. Do not look into the beam from a short distance without suitable protective eyewear. Do not look at LEDs with magnifiers or similar optical instruments that may concentrate the light output.

he fixture was designed for outdoor use. This fixture must not be used for underwater installation.
When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust.
Avoid using the unit in locations subject to possible impacts.
The fixture body never must be covered with cloth or other materials when the fixture is under operation.
Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened.

The fixture becomes hot during operation. Allow the fixture to cool approximately 30 minutes prior to servicing or maintenance.
Operate the fixture only after having familiarized yourself with its functions. Do not permit operation by persons not qualified to operate the fixture. Most damages are the result of unprofessional operation!
Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons!
Please use the original packaging if the fixture is to be transported.
If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the warranty becomes void. Furthermore, any other operation may lead to dangers like short- circuit,
burns, electric shock etc.
The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m.
Immunity of the equipment is designed according to the standard EN 55035 Electromagnetic compatibility of multimedia equipment – Immunity requirements Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment – Emission Requirements according to class B.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
The [Device] wireless operation is safe and complies to RF Exposure requirements.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help

Warning for fixtures with Harsh Environment Finish (HEF): Handle with care!
Avoid any damage to the painted surface.
Damaging the paint may result in corrosion and loss of warranty

Fixture exterior view

  1. Transparent glass cover
  2. LED module
  3. Output connector
  4. Input connector
  5. Mounting brackets
  6. Aluminium baseFixture exterior view

Installation

Mounting the fixture
The Eminere can be arranged in any orientation on a flat, non-flammable surface by means of two mounting brackets (5), the LED module (2) can be tilted (+95°/-95°) to get access to mounting brackets (5).
. Installation

Ensure that the structure to which you are attaching the unit is secure.

C-clamps installation
  1. Remove the mounting bracket (5) from fixture housing by unscrewing two screws (6).
  2. Screw the new mounting bracket (9) to the fixture housing by means of two screws (6).
  3. Screw the clamp (7) to the mounting bracket by means of the bolt M12x30 (10) with nuts M12 (8).Installation
    Installation
    Installation  Installation
Connection to mains

The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.
This device falls under class one and must be grounded!

The Eminere is equipped with auto-switching power supply that automatically adjusts to any 50/60Hz AC power source from 120-277 Volts.
The following wiring of the input/output connectors applies to the fixtures marked X on their labels only. Older versions of the Emineres have swapped D- and D+ and do not have mark X on their labels. E.g.

Connection to mains

Input – panel connector
(front view)
Connection to mains

Output – panel connector
(front view)

Connection to mains

Fixture´s Amphenol connectors are dust and water protected according to IP 67 by mating with related Amphenol connectors.
They cannot stay disconnected outdoor.
The output panel connector at last fixture in the Emineres chain has to always be covered with the water-tight cap to keep declared IP rating.

Do not connect (disconnect) Emineres to the Booster box and each other when they are under voltage!

Direct visibility between a transmitter and the Eminere Wireless DMX must be ensured without no obstacles (bildings, trees,….).
Distance between a DMX transmitter and the Eminere Wireless DMX depends on transmission range of used DMX transmitter, surrounds etc (we recommend to test behaviour of DMX transmitter with the Eminere Wireless DMX before installation).

Examples of connection

Examples of connection

Examples of connection

Wireless DMX to wire DMXWireless DMX to wire DMX

The Eminere can be only linked to a transmitter by running the link procedure at DMX transmitter.
The Eminere can be unlinked from the transmitter by running the unlink procedure at DMX transmitter or by switching off/on the Eminere three times while the transmitter is switched off.
During off/on unlink procedure, the Eminere has to be switched on for 5 seconds in steps 1-3:
Step 1: Eminere Off, Eminere On (5seconds)
Step 2: Eminere Off, Eminere On (5seconds)
Step 3: Eminere Off, Eminere On (5seconds)
Step 4: Eminere Off, Eminere On
Successful unlink is signalized by flashing LEDs at fourth switching the Eminere Off and On. If the LEDs flashing will not appear, probably the 5 seconds period has not been kept and you have to repeat the Off/On procedure to unlink the fixture from the DMX transmitter .

DMX addressing of connected Emineres has to be done manually by means of the Robe Universal Interface WTX and the software RDM Manager.

The tables below state max. theoretical number of Emineres connected in series without Booster boxes.

EMINERE 2 wireless DMX Voltage
Cable length * 120V 190V 230V 277V
10 m 32 32 32 32
20 m 32 32 32 32
30 m 28 32 32 32
50 m 17 32 32 32
70 m 12 31 32 32
100 m 9 21 32 32
EMINERE 3 wireless DMX Voltage
Cable length * 120V 190V 230V 277V
10 m 28 32 32 32
20 m 28 32 32 32
30 m 19 32 32 32
50 m 12 29 32 32
70 m 8 21 31 32
100 m 6 15 21 31
EMINERE 4 wireless DMX Voltage
Cable length * 120V 190V 230V 277V
10 m 21 32 32 32
20 m 21 32 32 32
30 m 15 32 32 32
50 m 9 22 32 32
70 m 6 16 23 32
100 m 4 11 16 23

* Cable length is a total cable length among connected Emineres Side including power cable of the first Eminere Side.
Example: Total cable length=L1+L2+L3

Wireless DMX to wire DMX

The Booster box

To compensate a voltage drop in a large installation, the Booster boxes have to be connected in the chain of Emineres.
The following tables give numbers of Emineres after which the Booster box has to be installed in the chain of Emineres.

EMINERE 2Wireless DMX

Max. possible number of Emineres 2 Wireless DMX = 32
Voltage
Cable length 120V 190V 230V 277V
10 m
20 m
30 m 28
50 m 17
70 m 12,24, 31
100 m 9,18 21 31
EMINERE 3 Wireless DMX Max. possible number of Emineres 3 Wireless DMX = 32
Voltage
Cable length 120V 190V 230V 277V
10 m 28
20 m 28
30 m 19
50 m 12,24 29
70 m 8,16,24 21 31.
100 m 6,12,18,24,30 15,30 21 31
EMINERE 4 Wireless DMX Max. possible number of Emineres 4 Wireless DMX = 32
Voltage
Cable length 120V 190V 230V 277V
10 m 21
20 m 21
30 m 15,30
50 m 9,18,27 22
70 m 6,12,18,24,30 16 23
100 m 4,8,12,16,20,24,28 11,22 16 23

Example: E-box Daisy, Power supply= 120V, Cable length=70m, fixture=Eminere 2 wireless DMX The Booster box has to be connected after every 12th Eminere 2 wireless DMX (fixture 12 and fixture 24) from 32 fixtures.

Wireless DMX to wire DMX

The Booster box installation

ALWAYS DISCONNECT THE EMINERES FROM MAINS BEFORE CONNECTING/DISCONNECTING THE BOOSTER BOX.

The Booster box falls under protection class I. Therefore, every Booster box has to be connected to a mains socket outlet with a protective earthing connection.

  1. Unscrew the four screws (1) from the cover (2) on the Booster box to get access to the terminal block (3) and two mounting holes of diameter of 4.6 mm (4).
  2. Screw the Booster box on a non-flammable flat surface and connect cables.
    The Booster box installation
    The Cable gland M20x1.5 for Power IN (5) is intended for a cable of a diameter of 7-13mm. Remove the end cap from the cable gland before passing the cable. Power connection
    L N  (earth)
    Core (EU) Braun Blue Green/yellow
    Core (US) Black White Green

     

    We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread of the gland body in case of unscrewing the cable gland from the housing of the buster box and repeatedly screwing it back to the housing .

    Cable gland M20 MS:

    The Booster box installation
    The cable gland M20 MS with a standard seal serves for a cable of diameter of 6-12mm, for smaller diameter of cable (4-8mm) you have to remove the original seal from the cable gland M20 and use the enclosed reducing seal instead of it. The reducing seal for diameter of cable 4-8mm (P/N 13051388) is enclosed in the Booster box.

    Standard seal • part of cable gland M20 x LS( for diameter of cable: 7-13nvn)

    The Booster box installation

    Reducing seal (P/N 130SL388) • enclosed, standard seal has to be removed before installing this: seal (for diameter or cable: 4·8mm)

    The Booster box installation

  3. Screw the cover (2) back on the Booster box.
Jumper cable assembling
  1. Dismantle the connector and slide its parts onto the cable (6).
    Use the seal with inner diameter of 14.5 mm for the Anolis cable (P/N 13053138 or P/N 13053139).
    The seal with inner diameter of 14.5 mm serves for cable of diameter 10-14.5mm.
    The seal with inner diameter of 10 mm serves for cable of diameter 8-10mm.
    Parts of the connector
    Jumper cable assembling
  2. Put the seiling circle (2) on the connector with screws (1).
  3. Remove insulation from the cable (6) and from individual wires and fasten three terminals on data wires.
    CE version
    CE versionUS version
    US version
  4. Put parts of the connector on the cable (6) and connect wires to the connector. First connect power wires (L,N, Earth) and after that data wires (D+, D-, 0V). Avoid excessive torsion of data wires!
    CE version
     Jumper cable assembling
    US version
     Jumper cable assembling
  5. After connecting wires to the connector, tighten the three data wires (D+,D-, 0V) by means of the cable binder (7).
     Jumper cable assembling
  6. Screw the clamp ring (3) to the connector (1), insert the seal (4) to the clamp ring (3) and tighten the sealing nut (5) enough. During the steps DO NOT TWIST the cable (6).
  7. Use the same procedure to assemble the connector on the second end of the cable.

IMPORTANT
Do not bend the cable near to the connector, minimum distance for bending is 50mm.
IMPORTANT

Technical specifications

Power supply

  • Electronic auto-ranging
  • Input voltage: 120 – 277V AC, 50/60 Hz
  • Power consumption:
    Eminere 2: 45W
    Eminere 3: 65W
    Eminere 4: 85W
  • Inrush current:
    Eminere 2: <70A/250µs
    Eminere 3: <100A/200µs
    Eminere 4: <100A/200µs
    Optic
  • Light source:
    Eminere 2: 24 x high power LEDs
    Eminere 3: 36 x high power LEDs
    Eminere 4: 48 x high power LEDs
  • Colour variants: RGBW, RGBA, single colour
  • Beam Angle:
    Symetrical: 9°, 15°, 30°, 50°, 65°, 100°
    Bi-symetrical: 10° x 30°, 30° x 10°, 10° x 60°, 60° x 10°, 35° x 70°, 70° x 35°, 15° x 90°, 90° x 15°
    Wallwasher, Wide Wallwasher
  • Projected Lumen Maintenance: L90B10 >90.000 hrs, Ta = 25°C / 77°F
    Wireless DMX/RDM module RW 001
  • Supported protocols: full RDM support, CRMX , W-DMXTM G2, G3,G4 and G4S
  • Operational frequency range: 2402-2480 MHz
  • Output power: 100 mW
  • Receiver sensitivity (0.1% BER): -93 dBm
  • Crystal Clock Frequency : 16.0 MHz
  • Contains FCC ID: 2A6PL-DMXRDMRW001
  • Contains IC: 29573-DMXRDMRW001
    Mounting method
  • Via two L-shape brackets
  • LED module “tilt” adjustment range: -95°/+95°
    Sizes
  • Eminere 2 (600mm / 2ft)
  • Eminere 3 (900mm / 3ft)
  • Eminere 4 (1200mm / 4ft)
    Housing
  • Aluminium extruded body with die-casted end caps
  • Tempered glass
    Cooling system
  • Convection

Total heat dissipation

  • Eminere 2: 130 BTU/h (calculated)
  • Eminere 3: 177 BTU/h (calculated)
  • Eminere 4: 228 BTU/h (calculated

Protection factor

    • CE: IP 67
    • US: Suitable for wet location
      Impact rating
    • CE: IK06
      Operating ambient temperature range
    • -20°C /+40°C (-4°F /+104°F)
      Operating temperature
    • +67°C @ Ambient +40°C (+153°F @ Ambient +104°F)
      Connection
    • Input: panel connector Amphenol ABAB-DMQ06000021-IN (P/N13052952)
    • Output: panel connector Amphenol ABAB-DAQ06000021 (P/N13052953) + water-tight cap
      Weight
    • Eminere 2: 4 kg (8.82 lbs)
    • Eminere 3: 6.02 kg (13.27 lbs)
    • Eminere 4: 7.7 kg (17 lbs)
      Dimensions (All dimensions in mm [inch])

Technical specifications

  • Booster box
    Technical specifications
  • C-Clamp
    Technical specifications

Included items
• 1 x Eminere
• 1 x User manual
Optional accessories
CE Leader Cables FF:
Leader Cable FF 2m (P/N 13053438)
Leader Cable FF 5m (P/N 13053440)
Leader Cable FF 10m (P/N 13053436)
Leader Cable FF 25m (P/N 13053437)
Leader Cable FF 50m (P/N 13053439)
US Leader Cables FF:
Leader Cable FF 2m (P/N 13053433)
Leader Cable FF 5m (P/N 13053435)
Leader Cable FF 10m (P/N 13053431)
Leader Cable FF 25m (P/N 13053432)
Leader Cable FF 50m (P/N 13053434)
Jumper Cables FF/FM:
Jumper Cable FF/FM 0.25m (P/N 13053422)
Jumper Cable FF/FM 0.5m (P/N 13053423)
Jumper Cable FF/FM 1m (P/N 13053425)
Jumper Cable FF/FM 2m (P/N 13053427)
Jumper Cable FF/FM 3m (P/N 13053428)
Jumper Cable FF/FM 5m (P/N 13053430)
Jumper Cable FF/FM 10m (P/N 13053424)

Waterproof Cover Cap FM ZAHB-0006 (P/N 17031173)
Field Installable Connector FF (P/N 13053003)
Field Installable Connector FM (P/N 13053004)
C-clamp adaptors for Eminere (P/N 10980860)
E-boxes:
E-box Daisy (P/N 10063655)
E-box Daisy/W (P/N 10063638)
E-box Lite (P/N 10063657)
E-box Lite/W (P/N 10063653)
E-box Star (P/N 10063656)
E-box Star/W (P/N 10063644)

Booster box (P/N 10063712)
Shield for Eminere 2 RAL9011 (P/N 10980489)
Shield for Eminere 3 RAL9011 (P/N 10980490)
Shield for Eminere 4 RAL9011 (P/N 10980491)
Cable Cover for Eminere 2 RAL9011 (P/N 10980485)
Cable Cover for Eminere 3 RAL9011 (P/N 10980486)
Cable Cover for Eminere 4 RAL9011 (P/N 10980487)
Mounting Brackets for Eminere 100mm, 2pcs RAL9011 (P/N 10980493)
Mounting Brackets for Eminere 200mm, 2pcs RAL9006 (P/N 10980529)
Mounting Brackets for Eminere 200mm, 2pcs RAL9011 (P/N 10980494)
Mounting Brackets for Eminere 300mm, 2pcs RAL9006 (P/N 10980576)
Mounting Brackets for Eminere 300mm, 2pcs RAL9011 (P/N 10980495)
Mounting Brackets for Eminere 50mm, 2pcs RAL9011 (P/N 10980525)

Cleaning and maintenance

DANGER !
Disconnect from the mains before starting any maintenance or cleaning work

Rinse off loose dirt with low pressure water spray. Wash the housing with a soft brush or sponge and a mild, nonabrasive washing detergent. Rinse it.
Maintenance and service operations are only to be carried out by a qualified person.
Should you need any spare parts, please use ROBE OEM parts.

Disposing of the product

To preserve the environment please dispose or recycle this product at the end of its life according to the local regulations and codes.

ChangeLog

This section summarizes changes in the user manual.

Version of manual Date of issue Description of changes
1.1 07/09/2021 Option Wireless DMX to wired DMX removed
1.2 05/10/2021 New DMX chart
1.3 13/10/2021 Technical specifications changed
1.4 26/11/2021 Optional accessories changed
1.5 20/12/2021 Jumper cable mounting added
1.6 06/01/2022 Jumper cable mounting chaged
1.7 12/01/2022 Jumper cable mounting more specified
1.8 23/02/2022 Sealing circle added to jumper cable mounting
1.9 19/05/2022 QR code added
2.0 12/01/2023 DMX chart ver. 3.1
2.1 10/02/2023 DMX chart ver. 3.2
2.2 20/03/2023 Notes about EMC added
2.3 05/09/2023 C-clamp adaptor installation added
2.4 13/09/2022 Jumper and leader cables numbers changed
DMX protocol for: Eminere 1/2/3/4; Eminere Side 1/2/3/4;
Eminere Inground 2/4; Eminere Remote 1/2/3/4;
UVinere 2/4; UVinere Remote 1/2/4
Version: 3.2 (23 modes in total), software version 3.0 and higher
Mode/Channels in all Mode 1: RGBW(A)-8bit, Mode 2: RGB 8-bit, Mode 3: full RGBW(A)
1 2 3 4 5 6 7 8-10 Mode 4: White-full control, Mode 5: Reduced RGBW(A)
4 3 12 3 6 8 15 Reserved Mode 6- Reduced RGBW(A)+white control
Mode 7- full RGBW(A)+virtual colour wheel
RGBW(A) / RGB modes
Mode/channels DMX

Value

Function Type of control
1 2 3 4 5 6 7
1 Special functions
0 No function step
To activate following functions , stop in DMX value for at least 3 sec.
1-2 Save current DMX values to fixture as initial DMX values. step
3-4 Show saved initial DMX values step
5-6 Run factory demo sequences at switching fixture on (without DMX) step
7-255 Reserved
1 1 1 1 1 2 Red
0-255 Red LEDs saturation control (0-100%) proportional
2 3 Red Fine
0-255 Red LEDs saturation control fine proportional
2 2 3 2 2 4 Green
0-255 Green LEDs saturation control (0-100%) proportional
4 5 Green Fine
0-255 Green LEDs saturation control fine proportional
3 3 5 3 3 6 Blue
0-255 Blue LEDs saturation control (0-100%) proportional
6 7 Blue Fine
0-255 Blue LEDs saturation control fine proportional
4 7 4 4 8 White (Amber)
0-255 White LEDs saturation control (0-100%) proportional
8 9 White (Amber) Fine
0-255 White LEDs saturation control fine proportional
9 1 5 10 Green correction
0 Uncorrected white step
1-127 Minus green –> uncorrected white proportional
128 Uncorrected white (128=default) step
129-255 Uncorrected white –> Plus green proportional
10 2 6 11 Colour temperature correction (CTC)
0 No function step
1-10 Tungsten dimming 2700 K step
11-20 Tungsten dimming 3200 K step
21-255 Colour temperature changing from 1800 K –> 6500 K proportional
(21-1800K, 66-2700K, 91-3200K,141-4200K, 211 5600K 255- 6500K)
12 Virtual Colour Wheel
0 No function step

 

Mode/channels DMX Value Function Type of control
1 2 3 4 5 6 7
1-2 White 1800 K step
3-4 White 2700 K step
5-6 White 3200 K step
7-8 White 4200 K step
9-10 White 5600 K step
11-12 White 6500 K step
13 Blue (Blue=full, Red+Green+White/Amber=0) step
14-23 Red=0, Green->up,Blue =full, White/Amber=0 proportional
24 Cyan (Red=0, Green=full, Blue =full, White/Amber=0) step
25-34 Red=0, Green=full, Blue->down, White/Amber=0 proportional
35 Green (Red=0, Green=full, Blue =0, White/Amber=0) step
36-45 Red->up, Green=full, Blue=0, White/Amber=0 proportional
46 Yellow (Red=full, Green=full, Blue=0, White/Amber=0) step
47-56 Red=full, Green->down, Blue=0, White/Amber=0 proportional
57 Red(Red=full, Green=0, Blue=0, White/Amber=0) step
58-67 Red=full, Green=0, Blue->up, White/Amber=0 proportional
68 Magenta (Red=full, Green=0, Blue=full, White/Amber=0) step
69-78 Red -> down, Green=0, Blue=full, White/Amber=0 proportional
79 Blue (Red=0, Green=0, Blue=full, White/Amber=0) step
Transition effects
80-87 Rainbow effect (with fade time) from slow-> fast proportional
88-95 Rainbow effect (without fade time) from slow-> fast proportional
96-103 Full dynamic white (1800K->6500K->1800K) (with fade time) from

slow-> fast

proportional
104-111 Full dynamic white (1800K->6500K->1800K) (without fade time)

from slow-> fast

proportional
112-119 Dynamic warm white (1800K-3000K-1800K) (with fade time) from

slow-> fast

proportional
120-127 Dynamic warm white (1800K-3000K-1800K) (without fade time)

from slow-> fast

proportional
128-135 Rainbow effect + full dynamic white (with fade time) from slow->

fast

proportional
136-143 Rainbow effect + full dynamic white (without fade time) from

slow-> fast

proportional
144-151 Blue/Green effect (with fade time) from slow-> fast proportional
152-159 Blue/Green effect (without fade time) from slow-> fast proportional
160-167 Red/Blue effect (with fade time) from slow-> fast proportional
168-175 Red/Blue effect (without fade time) from slow-> fast proportional
176-183 Green/Red effect (with fade time) from slow-> fast proportional
184-191 Green/Red effect (without fade time) from slow-> fast proportional
192-199 Blue/4000K effect (with fade time) from slow-> fast proportional
200-207 Blue/4000K effect (without fade time) from slow-> fast proportional
208-215 Green/4000K effect (with fade time) from slow-> fast proportional
216-223 Green/4000K effect (without fade time) from slow-> fast proportional
224-231 Red/4000K effect (with fade time) from slow-> fast proportional
232-239 Red/4000K effect (without fade time) from slow-> fast proportional
240-255 Reserved
13 Shutter/Strobe
0-31 Shutter closed step
32-63 Shutter open step
Mode/channels DMX Value Function Type of control
1 2 3 4 5 6 7
64-95 Strobe-effect from slow to fast proportional
96-127 Shutter open step
128-143 Opening pulse in sequences from slow to fast proportional
144-159 Closing pulse in sequences from fast to slow proportional
160-191 Shutter open step
192-223 Random strobe-effect from slow to fast proportional
224-255 Shutter open step
11 3 5 7 14 Dimmer
0-255 Light intensity coarse (0-100%) proportional
12 6 8 15 Dimmer Fine
0-255 Light intensity fine proportional
Copyright © 2022-2023 Robe Lighting s.r.o. – All rights reserved
All Specifications subject to change without notice
DMX protocol for: Eminere 1/2/3/4; Eminere Side 1/2/3/4;
Eminere Inground 2/4; Eminere Remote 1/2/3/4;
UVinere 2/4; UVinere Remote 1/2/4
Version: 3.2 (23 modes in total)
Mode/Channels in all Mode 11: White selection, Mode 12: WW + CW
11 12 13 14-16 Mode 13: Only dimmer
3 4 2 Reserved Mode 13 is suitable for UVinere and UVinere Remote
TW and PW modes
Mode/channels DMX

Value

Function Type of control
11 12 13
1 White colour selection
0 – 255 White from 2700 K – 6500 K proportional
1 Warm White
0 – 255 Warm White LEDs saturation control (0-100%) proportional
2 Cool White
0 – 255 Cool White LEDs saturation control (0-100%) proportional
2 3 1 Dimmer
0 – 255 Light intensity coarse (0 – 100%) proportional
3 4 2 Dimmer Fine
0 – 255 Light intensity fine proportional
Copyright © 2022-2023 Robe Lighting s.r.o. – All rights reserved
All Specifications subject to change without notice
DMX protocol for: Eminere 1/2/3/4; Eminere Side 1/2/3/4;
Eminere Inground 2/4; Eminere Remote 1/2/3/4;
Version: 3.2 (23 modes in total)
Mode/Channels in all Mode 17: RGBW(A) pixels, Mode 18: RGB pixels, Mode 19: TW pixels,
17 18 19 20 21-23 Mode 20: PW dimmer pixels
16 12 8 8 Reserved
Pixel modes
Mode/channels DMX

Value

Function Type of

control

17 18 19 20
1 1 Red 1 -Eminere 1/2/3/4
0 – 255 Red LEDs saturation control (0-100%) proportional
2 2 Green 1-Eminere 1/2/3/4
0 – 255 Green LEDs saturation control (0-100%) proportional
3 3 Blue 1-Eminere 1/2/3/4
0 – 255 Blue LEDs saturation control (0-100%) proportional
4 White (Amber) 1-Eminere 1/2/3/4
0 – 255 White LEDs saturation control (0-100%) proportional
5 4 Red 2 -Eminere 2/3/4
0 – 255 Red LEDs saturation control (0-100%) proportional
6 5 Green 2-Eminere 2/3/4
0 – 255 Green LEDs saturation control (0-100%) proportional
7 6 Blue 2-Eminere 2/3/4
0 – 255 Red LEDs saturation control (0-100%) proportional
8 White (Amber) 2-Eminere 2/3/4
0 – 255 White LEDs saturation control (0-100%) proportional
9 7 Red 3-Eminere 3/4
0 – 255 Red LEDs saturation control (0-100%) proportional
10 8 Green 3-Eminere 3/4
0 – 255 Green LEDs saturation control (0-100%) proportional
11 9 Blue 3-Eminere 3/4
0 – 255 Blue LEDs saturation control (0-100%) proportional
12 White (Amber) 3-Eminere 3/4
0 – 255 White LEDs saturation control (0-100%) proportional
13 10 Red 4-Eminere 4
0 – 255 Red LEDs saturation control (0-100%) proportional
14 11 Green 4-Eminere 4
0 – 255 Green LEDs saturation control (0-100%) proportional
15 12 Blue 4-Eminere 4
0 – 255 Blue LEDs saturation control (0-100%) proportional
16 White (Amber) 4 -Eminere 4
0 – 255 White LEDs saturation control (0-100%) proportional
1 Warm White 1 -Eminere 1/2/3/4
Warm White LEDs saturation control (0-100%) proportional
2 Cool White 1-Eminere 1/2/3/4
0 – 255 Cool White LEDs saturation control (0-100%) proportional
3 Warm White 2-Eminere 2/3/4
Mode/channels DMX

Value

Function Type of

control

17 18 19 20
0 – 255 Warm White LEDs saturation control (0-100%) proportional
4 Cool White 2-Eminere 2/3/4
0 – 255 Cool White LEDs saturation control (0-100%) proportional
5 Warm White 3-Eminere 3/4
0 – 255 Warm White LEDs saturation control (0-100%) proportional
6 Cool White 3-Eminere 3/4
0 – 255 Cool White LEDs saturation control (0-100%) proportional
7 Warm White 4 -Eminere 4
0 – 255 Warm White LEDs saturation control (0-100%) proportional
8 Cool White 4 -Eminere 4
0 – 255 Cool White LEDs saturation control (0-100%) proportional
1 Dimmer 1
0 – 255 Light intensity coarse (0 – 100%) proportional
2 Dimmer Fine 1
0 – 255 Light intensity fine proportional
3 Dimmer 2
0 – 255 Light intensity coarse (0 – 100%) proportional
4 Dimmer Fine 2
0 – 255 Light intensity fine proportional
5 Dimmer 3
0 – 255 Light intensity coarse (0 – 100%) proportional
6 Dimmer Fine 3
0 – 255 Light intensity fine proportional
7 Dimmer 4
0 – 255 Light intensity coarse (0 – 100%) proportional
8 Dimmer Fine 4
0 – 255 Light intensity fine proportional
Copyright © 2022-2023 Robe Lighting s.r.o. – All rights reserved
All Specifications subject to change without notice

Specifications are subject to change without notice. September 5, 2023
Copyright © 2019-2023 Robe Lighting – All rights reserved/
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici

QR code for user manual
QR cod

Logo

 

Documents / Resources

Anolis 2-3-4 Eminere Wireless DMX [pdf] User Manual
2-3-4 Eminere Wireless DMX, 2-3-4, Eminere Wireless DMX, Wireless DMX

References

Leave a comment

Your email address will not be published. Required fields are marked *