HVW-C Series Digital Scale
“
Specifications:
- Product Name: Digital Scale
- Model: HVW-C Series
- Features: Comparator Memory, Preset Tare Value Memory
Product Usage Instructions:
Command Mode for Comparator Memory:
In command mode, the scale can be controlled by commands from
external devices such as computers.
List of Commands for Comparator Memory:
Command | Function |
---|---|
CN | Switch Comparator Memory (Switch the memory in use) |
?CN | Output Comparator Memory (Output the memory in use) |
Command Examples:
Switch Comparator Memory
Switch the comparator memory in use to the specified memory
number.
Command Response Example: C N , X X CR LF XX is the memory
number. 00 to 99
Output Comparator Memory
Output the comparator memory in use.
Command: ? C N CR LF
Response Example: C N , X X CR LF XX is the memory number. 00 to
99
Preset Tare Value Memory:
Input the tare amount digitally.
- While pressing the SET key, press the TARE key to display a
blank or the stored tare amount. PT will blink. - Enter the tare amount using the numeric keypad.
- Press the ENTER key to save. It will return to the mass
display, showing the measured value minus the set amount. - Place the item to be weighed in the container, and read the
value after the stability mark lights up. - Remove the item from the plate.
FAQ:
How can I confirm if my product is eligible for the
supplement?
You can confirm by checking either the software version or the
presence of a QR code on the display.
How to Check Software Version:
- Press the ON/OFF key to turn off the power.
- While pressing the Tare key, press the ON/OFF key to display
the software version. - Press the ON/OFF key to turn off the power.
How to Check for Presence of a QR Code:
Check that there is a QR code on the upper right of the numeric
display section of the indicator.
“`
Command Mode for Comparator Memory
All sections are supplementary content. * This feature may not be available depending on when the product was purchased. In command mode, the scale can be controlled by commands from external devices such as computers.
List of Commands for Comparator Memory
Command
Function
CN Switch Comparator Memory (Switch the memory in use)
?CN Output Comparator Memory (Output the memory in use)
Command Examples
Below is an example for Function table
(with command response).
For Function table
, there is no response.
Switch Comparator Memory
Switch the comparator memory in use to the specified memory number.
Command Response example
C N , X X CR LF XX is the memory number.00 to 99
C N , X X CR LF No response with
.
Output Comparator Memory
Output the comparator memory in use.
Command
? C N CR LF
Response example C N , X X CR LF XX is the memory number.00 to 99
Preset Tare Value Memory
Sections indicated with double underlines are supplementary content. * This feature may not be available depending on the purchase time.
How to Input Digitally (Preset Tare)
Input the tare amount digitally. (Preset Tare)
Step 1 While pressing the SET key, press the TARE key to display a blank or the stored tare amount. (If the tare amount is zero, it will be blank.) PT will blink.
Step 2 Enter the tare amount using the numeric keypad.
Step 3 Press the ENTER key to save. It will return to the mass display, showing the measured value minus the set amount.
Step 4 Place the item to be weighed in the container, and read the value after the stability mark lights up.
Step 5 Remove the item from the plate.
Supplement to HVW-C Series Instruction Manual
There is a supplement to the contents described in the HVW-C Series Digital Scale Instruction Manual. Please replace with the contents of this document and use the supplement. The applicable models are as follows.
Models HV-C/CP, HW-C/CP series1WMPD4003471* HV-CWP/HW-CWP series1WMPD4003559*
Note that the supplement applies to products with software version “P-1.20” or later. Please check “How to Confirm Applicable Products” below to see if the supplement applies.
The following three functions have been added in the new version “P-1.20” or later. Main Specification Changes
Comparator memory
Preset memory Operations when keys locked
Old
1
No memory function Applies to key operations, external contacts, and commands too.
New
100
With memory function Only Key Operations are Included(External Contacts and Commands are Excluded)
How to Confirm Applicable Products
You can confirm whether this supplement applies by checking either the “software version” or the presence of a QR code on the display.
How to Check the Software Version
Press the ON/OFF key to turn off the power.
While pressing the Tare key, press the ON/OFF key to display the software version press the ON/OFF key to turn off the power.
. When finished,
How to Check for the Presence of a QR Code
Check that there is a QR code on the upper right of the numeric display section of the indicator. (See the figure below)
egHV-C series
M AX
d
M ANUAL
Range
egHV-CWP series
M ANUAL
* The registered value will remain saved even if the power is turned off.
1WMPD4005546
4
1
Comparator Memory and Comparison Value Settings
All sections are supplementary content. * This feature may not be available depending on when the product was purchased.
Comparator Memory Function
The comparator memory function can store multiple types of comparison value settings for the comparator function. It can store up to 100 types. (Memory numbers: 00 to 99)
How to Select Comparator Memory
From the mass display, press the SET key while pressing the COMP Limit key to enter the comparator memory setting mode. * If the comparator memory function is not available, the display will switch to the
comparison value setting screen instead of the comparator memory setting.
The currently selected memory number (00 to 99) will be displayed. Use the 0 to 9 keys to switch the display of memory numbers. The stability mark will light up for the currently selected memory number.
Enter the memory number you want to select and press the ENTER key to set
the comparator memory. After
displaying, it will return to the mass
display.
Setting Comparison Values
From the mass display, press the SET key while pressing the COMP Limit key to enter the comparator memory setting mode. * If the comparator memory function is not available, the display will switch to the
comparison value setting screen instead of the comparator memory setting.
The currently selected memory number (00 to 99) will be displayed. Use the 0 to 9 keys to switch the display of memory numbers. The stability mark will light up for the currently selected memory number.
Enter the memory number for which you want to set the comparison value and press the SET key to set the comparator memory and enter the comparison value setting mode.
Please set each comparison value using the following key operations.
0 to 9 : Numeric input SET : Toggle between and ENTER : Confirm (register) the set value C : Cancel
* Each time you press the SET key, the “” sign will repeatedly light up and turn off at the highest digit. When lit, it
indicates
a negative setting.
* The ‘- K’ models do not have the +/- toggle function with the Set key. Once all settings are complete, the screen will return to the mass display after showing taken at this time.)
. (Power-on zero is not
Setting 5-Stage Sorting Mode
e.g. Example of HW-60KC settings.
LOLO
8.500 kg
LO
10.000 kg
HI
10.500 kg
HIHI
12.000 kg
Memory number Display
SET Press
Setting 3-Stage Sorting Mode Upper/Lower Limit Mode
e.g. Example of HV-200KC
LO
148.85 kg
HI
152.50 kg
Memory number Display
Press
Setting 7-Stage Sorting Mode Ranking Mode
e.g. Example of HV-15KC
Rank 1 (LOLO) 0.500 kg or more
Rank 2 (LO) 1.000 kg or more
Rank 3 (OK) 1.500 kg to 2.000 kg
Rank 4 (HI)
less than 2.500 kg
Rank 5 (HIHI)
less than 3.000 kg
Memory number display
Press
LOLO setting Lower-lower limit value setting Press
LO setting Lower limit value Press setting
HI setting Upper value setting Press
HIHI setting Upper-upper limit value Press setting
LO setting Lower limit value setting Press HI setting Upper value setting Press
Press
Rank 1 Lower limit value setting Press
Rank 2 Lower limit value Press setting
Rank 3 Lower limit value Press setting
Rank 3 Upper value setting Press
Rank 4 Upper value setting Press
Press
Rank 5 Upper value Press setting
* For HV-C/CP series and HV-CWP series, the smallest display digit changes depending on the display range. Please enter 0 for the last display digit.
Press
2
3
Documents / Resources
![]() |
AND HVW-C Series Digital Scale [pdf] Instruction Manual HV-C-CP, HW-C-CP series1WMPD4003471, HV-CWP-HW-CWP series1WMPD4003559, HVW-C Series Digital Scale, HVW-C Series, Digital Scale, Scale |