PI2-MS PPB Oxygen Analyzer
“
Product Information
Specifications:
- Product Name: PPB Oxygen Analyzer – Trace Oxygen Analyzer
- Model: PI2-MS X48A0T51
- Ordering Code: {Feature A}+{Feature B}+{Feature C}+{Feature
D}+…+{Feature X} - Features:
- Base Model: PI2-MS Oxygen Analyzer (PPB)
- Configuration:
- B1: Bench/Panel mount
- B3: Wall Mount
- B4: Wall Mount (W306)
- B5: Carrying Case w/ VCR Fittings
- Sample System:
- C1: Standard
- C3: Internal pressure regulator (REG-1021)
- Sensor: GPR-12-2000-MS2E (Lowest range 0-500 PPB)
- Power:
- G1: UK
- G2: Europe
- G3: USA
- G4: Australia
- Certificates:
- M2: NIST Calibration Cert
- Options:
- X3: 19 Rack Mount (via Bezel)
Product Usage Instructions
Installation:
- Select the appropriate configuration (B1, B3, B4, B5) for
mounting. - Choose the desired sample system (C1, C3) based on your
requirements. - Install the sensor (D2) as per the provided guidelines.
- Connect the power supply according to your region (G1, G2, G3,
G4). - If necessary, add certificates and options as per your
needs.
Operation:
- Ensure the analyzer is properly powered and calibrated.
- Follow the specific instructions for sample collection and
analysis provided in the user manual. - Maintain the sensor and sample system regularly for accurate
readings.
Maintenance:
- Clean the sensor and sample system components as recommended by
the manufacturer. - Perform routine calibration checks to ensure accurate
measurements. - Replace sensor components as needed to maintain
performance.
Frequently Asked Questions (FAQ)
Q: Can I use a different power lead than the one specified in
the ordering code?
A: It is recommended to use the specified power lead to ensure
compatibility and safe operation of the analyzer.
Q: How often should I calibrate the sensor?
A: Calibration frequency may vary based on usage, but it is
generally recommended to calibrate the sensor regularly, at least
once every few months.
“`
PI2-MS X48A0T51
PPB Oxygen Analyzer – Trace Oyxgen Analyzer
Product Parent Code: PI2-MS General Purpose PPB Oxygen Analyzer with barometric pressure and temperature compensation measurement range: 0-500 PPB O2; manual or auto-ranging; programmable auto-zero and auto-span capability 2 user configurable alarm contacts; 4-20mA isolated, 0-1V DC, 0-5V DC signal outputs;1-5V DC range ID outputs; RS232 Supplied with heated sample system; stainless steel wetted parts, flow control needle valve, bypass valve, flow indicator and 1/4″ tube fittings universal AC power supply; panel mount/benchtop enclosure.
Product Ordering Code {Feature A}+{Feature B}+{Feature C}+{Feature D}+…+{Feature X}
Feature
Item
Description
Feature {A} Base Model
PI2-MS
Oxygen Analyzer (PPB)
Feature {B} Configuration
PI2-MS B1
Bench/Panel mount
PI2-MS B3
Wall Mount
PI2-MS B4
Wall Mount (W306)
PI2-MS B5
Carrying Case w/ VCR Fittings
Feature {C} Sample System
PI2-MS C1
Standard
PI2-MS C3
Internal pressure regulator (REG-1021)
Feature {D} Sensor
D2
GPR-12-2000-MS2E (Lowest range 0-500 PPB)
Feature {G} Power
I2-UHP G1
UK
G2
Europe
G3
USA
G4
Australia
Feature {M} Certificates (Only add if required)
* M2
NIST Calibration Cert
Feature {X} Options (only if required)
X3
19″ Rack Mount (via Bezel)
* On certain labor intensive services, no discount can be offered. These items are always offered at list price.
Ordering Examples
PI2-MS +B3+C1+D2+G2+M1
Oxygen Analyzer (PPB), Wall mount, Standard Sample System (with HSS), GPR-12-2000-MS2E sensor (Lowest range 0-500 PPB), European power lead, NIST calibration certificate
Order Code
Replacement Sensors GPR-12-2000-MS2E
Description PPB replacement sensor
Please note: Analytical Industries Inc. adopts a continuous development program which sometimes necessitates specification changes without notice. Please contact us for the latest version. Issue No: PI2-MS/UHP_V5
Documents / Resources
![]() |
Analytical Industries PI2-MS PPB Oxygen Analyzer [pdf] Instructions PI2-MS X48A0T51, GPR-12-2000-MS2E, PI2-MS PPB Oxygen Analyzer, PI2-MS, PPB Oxygen Analyzer, Oxygen Analyzer, Analyzer |