HTMR-COB Series High Output 10M Max Run COB Tape Light
“
Product Information
Specifications
- Product Series: HTMR-COB Series
- Wattage: 3W/ft
- Cut Increments: 1.64
- Maximum Run Length: 32.8 feet (98.4 watts)
- Power Requirement: 24V DC Class 2 drivers
Product Usage Instructions
Installation
- Ensure the electrical power to the system is disconnected at
the source. - Install the products in accordance with the provided
instructions, current electrical codes, and NEC. - Use only with 24V DC Class 2 drivers with appropriate wattage
capacity. - Pay attention to layout considerations, including maximum run
lengths. - Properly connect the conductors for a secure installation.
Frequently Asked Questions (FAQ)
Q: What should I do if I encounter a possible shock or fire
hazard?
A: If you suspect a hazard, immediately disconnect the power
source and seek professional assistance to address the issue.
Q: Can I use a power supply other than a 24V DC Class 2
driver?
A: No, using a non-recommended power supply will void the
factory warranty and may pose safety risks.
Q: How do I ensure a proper connection of the product?
A: Follow the provided instructions carefully and pay attention
to layout considerations, including maximum run lengths, to ensure
a secure connection.
“`
24V TRULUX® STATIC WHITE (IP54)
INSTALLATION INSTRUCTIONS
HTMR-COB Series
WARNING
These products may represent a possible shock or fire hazard if improperly installed or attached in any way. Products should be installed in accordance with these instructions, current electrical codes, and/or the current National Electric Code (NEC).
WARNING
Use only with 24V DC Class 2drivers with a wattage capacity that can handle the total load. Factory warranty will be void if used with a non-recommended power supply, transformer or driver.
WARNING
To reduce the risk of fire, electric shock or injury to persons, make sure that the electrical power to the system is disconnected at the source prior to installation or any servicing.
WARNING
Never fold Trulux® or bend past the minimum bending radius of 1″ whether lighted or unlighted.
SAFETY INFORMATION · Read all installation instructions before beginning; if not qualified, do not attempt installation. Contact a qualified electrician. · To reduce the risk of fire, electric shock, or injury to persons, pay close attention to this manual and stay within its guidelines when using this product. Save these instructions for future use. · Do not cover this product with paper surface coverings, fabrics,
streamers, or other similar combustible materials. · Do not operate Trulux on the reel, nor while it is coiled. · This IP54 rated tape light is suitable for indoor use in dry and damp
locations, but not for direct contact with water or moisture. Do not submerge flexible light in liquids, or use the product in the vicinity of standing water or other liquids, or where water can accumulate. · Do not route the cord or tape light through walls, ceilings, doors, windows, or any similar part of the building structure. · Secure tape light using only the adhesive provided with the tape and/or factory recommended mounting clips, mounting track, and aluminum channel (sold separately). · Do not secure this product or its cord with staples, nails, or like means that may damage the outer jacket or cord insulation. · Do not use if there is any damage to the tape light, diodes or power cord insulation; inspect periodically. · Do not install on gates or doors, or where subject to continuous flexing. · Do not install in airtight tanks or enclosures of any kind. · Size your 24V DC driver appropriately for your run distance. Be sure not to load a driver to 100% as this will reduce its efficiency; a 90% maximum load is recommended.
LAYOUT CONSIDERATIONS Pay close attention to the following maximum run lengths:
Series
Wattage
HTMR-COB Series 3W/ft
Cut Increments 1.64″
Maximum run 32.8 feet (98.4 watts)
PRODUCT INFORMATION Mount tape light using the 3M® VHB adhesive on back of tape. Once the VHB protective backing is removed, the tape should be placed on the prepared mounting surface and not be repositioned, removed, or re-used. For best results, let adhesive cure 24 hours prior to first use.
Trulux® tape light utilizes a nano-coating for ingress protection. It is recommended to scrape off the coating from each
conductor to ensure a proper connection.
©2025 American Lighting, Inc. REV2531 www.AmericanLighting.com
Page 1 of 3
11775 E. 45th Ave. Denver, CO 80239 Ph: 1-800-880-1180 Fax: 303-695-7633
24V TRULUX® STATIC WHITE (IP54)
INSTALLATION INSTRUCTIONS
HTMR-COB Series
CUTTING & LINKING TRULUX® TAPE LIGHT: Do not exceed the maximum tape light run length in any single run. Cut increments are clearly marked on the tape light (see Layout Considerations on Page 1). LED Strip length may vary, however, the power of the total length s hould not exceed the output of the Class 2 power supply.
ADDITIONAL SAFETY MEASURES 1. Route and secure cords so that they will not be pinched or damaged in any way. 2. LEDs are bright. Do not look directly at lighted tape light. Important Note: The National Electrical Code (NEC) does not permit cords to be concealed where damage to insulation may go unnoticed. To prevent fire danger, do not run cord behind walls, ceilings, soffits, or cabinets where it may be inaccessible for examination. Cords should be visually examined periodically and immediately replaced when damage is noted.
©2025 American Lighting, Inc. REV2531 www.AmericanLighting.com
Page 2 of 3
11775 E. 45th Ave. Denver, CO 80239 Ph: 1-800-880-1180 Fax: 303-695-7633
24V TRULUX® STATIC WHITE (IP54)
INSTALLATION INSTRUCTIONS
HTMR-COB Series
5- YEAR LIMITED PRODUCT WARRANTY This product is warranted to be free from defects in material and workmanship for a period of five years from the date of purchase. Products that prove to be defective during this period will be either repaired (i.e. replacement of defective electronics, defective parts of the fixture housing, lens, wiring, switching or lamp sockets; excluding the lamp) or replaced, at the discretion of American Lighting, Inc. Claims for defective products must be submitted to the retail location from which the product was purchased within the warranty period. Upon submission of proper return claim documentation and product to American Lighting, Inc by the retailer, American Lighting, Inc reserves the right to inspect the product for misuse or abuse. Claims for indirect or consequential damages or for product that, in American Lighting Inc’s opinion has been misused will be denied. This is a warranty of product reliability only and not a warranty of merchantability or fitness for a particular purpose. American Lighting, Inc shall have no liability whatsoever in any event for payment of incidental or consequential damages, including, without limitations, installation costs and damages for personal injury and property. These products may represent a possible shock or fire hazard if improperly installed or altered in any way. This warranty applies only to product that has been properly installed in accordance with instruction sheet and current local codes and/or the National Electrical Code. Warranty does not apply to any product that has been improperly installed or in situations where components have been altered in any way.
For questions, comments, technical assistance and/or repair parts, please call toll free at: 1-800-285-8051 (M-F 8am 5pm, MST)
©2025 American Lighting, Inc. REV2531 www.AmericanLighting.com
Page 3 of 3
11775 E. 45th Ave. Denver, CO 80239 Ph: 1-800-880-1180 Fax: 303-695-7633
Documents / Resources
![]() |
AMERICAN LIGHTING HTMR-COB Series High Output 10M Max Run COB Tape Light [pdf] Installation Guide HTMR-COB Series, HTMR-COB Series High Output 10M Max Run COB Tape Light, High Output 10M Max Run COB Tape Light, Output 10M Max Run COB Tape Light, 10M Max Run COB Tape Light, Run COB Tape Light, Tape Light |