SEM300 TROUBLESHOOTING
GUIDE

ADDRESSING THE KEYPAD

The default keypad address the SEM uses is Keypad 8 Device Address 23. If this keypad address is disabled, the SEM and panel will not communicate properly. However, at first power-up, the SEM will attempt to enable this address automatically. If unsuccessful, the address must be enabled manually via programming *196.

Keypad address DIP switch setting VISTA programming command
17 None—all OFF *190
18 Switch 4 ON, others OFF *191
19 Switch 3 ON, others OFF *192
20 Switch 3 and 4 ON, others OFF *193
21 Switch 2 ON, others OFF *194
22 Switch 2 and 4 ON, others OFF *195
23 Switch 2 and 3 ON, others OFF *196

If another keypad is occupying this address already, a different address must be selected for the SEM. To select a different keypad address, manually adjust the dual in-line package DIP switches on the SEM to match the desired keypad address listed below. Then, exit programming via *99.

GATEWAY LED REFERENCE

The enclosure gateway LEDs can be used to indicate communication errors, panel communication, network communication, and signal strength.
Note: For advanced troubleshooting, open the cover to look at the Alarm.com module LEDs.
ALARM COM SEM300 Communicator Device - icon TROUBLE LED
The TROUBLE LED flashes 1 to 8 times in a four-second interval to indicate specific error conditions.

Flash pattern Description
1 The Alarm.com module cannot communicate with the panel. Perform a power cycle on the panel. If the error persists, lift the Alarm.com module out of the SEM circuit board and re-insert it while power is disconnected from the system.
2 then 4 The Alarm.com module provisioning process could not be completed.
Power-cycle the system. If the error persists, see Alarm.com CORE Technical Support.
2 then 5 The Alarm.com module provisioning process could not be completed
because the module is currently roaming off the carrier’s primary network.
3 The Alarm.com module is trying to register on the cellular network. If it persists for more than a few minutes, the module is having problems registering. Check L4 for signal level. If signal level is lower than 2 bars, change the panel’s location or use a remote antenna option.
4 The Alarm.com module is registered on the cellular network but could not connect with Alarm.com. If the error persists, see Alarm.com CORE Technical Support.
5 The radio on the module is not working correctly. If this persists for more than a few minutes, the module may need to be replaced. This error is extremely rare, so please verify that the module is flashing 5 times.
6 This indicates an error only if it persists for more than a minute. Otherwise, it’s an indication that the module is resolving an unusual condition regarding communication with the cellular network.
7 The SEM is unable to access panel programming. Check the panel wiring and installer code.

8  Email alarms@alarmsystemstore.com or call Alarm System Store for assistance: 888-811-0727

ALARM COM SEM300 Communicator Device - icon 1 PATH LED
The PATH LED flashes to indicate the active communication path (cellular, broadband, or both) to Alarm.com.

Flash pattern Description
Steady long flash (~2 sec) The cellular communication path is active.
Long flash (~2 sec) followed by a short flash (~0.5 sec) Both cellular and broadband communication paths are active.
Steady short flash (~0.5 sec) The broadband communication path is active.
This should also accompany an error LED flash.
No flash Both communication paths are not communicating. This should also accompany an error LED flash.

ALARM COM SEM300 Communicator Device - icon 1. SIGNAL LED
The SIGNAL LED flashes to indicate the cellular signal strength (0 to 6 bars).
ALARM COM SEM300 Communicator Device - icon3 PANEL LED
The PANEL LED flashes with every communication to the panel.
ALARM COM SEM300 Communicator Device - icon4 POWER LED
The POWER LED illuminates solid when power is supplied.

SPECIFICATIONS

Power requirements 13.6 V nominal, 125 mA nominal (continuous), 230 mA maximum
Cellular network 4G LTE with 3G HSPA, 2G GSM fallbackTwo keypad BUS connections, 12 V power and ground Five LEDs (red, yellow, or green)
Five LEDs (red, green, yellow, or blue)
Operating temperature 14 to 131°F (-10 to 55°C)
Storage temperature -30 to 140°F (-34 to 60°C)
Humidity 90% relative humidity non-condensing
Enclosure dimensions (L x W x D) 7.66 x 4.35 x 1.65 in. (19.46 x 11.05 x 4.19 cm)
Enclosure color White
Case material Fire-retardant PC/ABS, PC