Unpacking

Before you begin using the device, please check the version you got and ensure that the following items are included in the shipped box:

Akuvox NS 2 Network Switch - Unpacking

Device Installation

Akuvox NS 2 Network Switch - Device Installation 1

Push out the two clasps completely.

Akuvox NS 2 Network Switch - Device Installation 2

Insert the guide groove on the raised part of the bottom of the equipment shell into one side of the guide rail, and fit the NS-2 on the guide rail.

Akuvox NS 2 Network Switch - Device Installation 3

Press down the NS-2 on the front, push the two clasps upwards, and make the buckles snap into the guide rail, and then fix it on to the guide rail.

Power Adapter Installation

Akuvox NS 2 Network Switch - Power Adapter Installation 1

Place the power adapter on the corresponding position of the guide rail as shown in the figure above, and fasten the plastic buckle on the guide rail to fix the power adapter.
Note: Power adapter was not provided in the shipped box, please purchase it separately if you need it.

Akuvox NS 2 Network Switch - Power Adapter Installation 2

Note: The power adapter is 48V/1.25A DC or 24V/2A DC. Please refer to Device Wiring section for more connection details.

Device Wiring

Akuvox NS 2 Network Switch - Device Wiring

Note:

  • Each NS-2 supports a maximum of 6 loads, otherwise, it may not be powered on or power off during
  • use.
    The PLC-S lead wire of NS-2 must be kept at least 5 cm away from the PLC-1~PLC-6 lead wire, otherwise the signal will loop back and the network cannot be used.

Application Network Topology

Topology-1: each device connect to NS-2 separately.

Akuvox NS 2 Network Switch - Application Network Topology 1

Adapter VoltageCable ModelFarthest DistanceAdapter VoltageCable ModelFarthest Distance
48V24awg300m24V24awg150m
20awg300m20awg250m
18awg300m18awg300m

Topology-2: devices are series connection with NS-2.

Akuvox NS 2 Network Switch - Application Network Topology 2

Adapter VoltageCable ModelFarthest DistanceAdapter VoltageCable ModelFarthest Distance
48V24awg100m/6devices
150m/4devices
200m/3devices
24V24awg50m/3devices 150m/ldevice
20aw g250m/6devices
300m/5devices
20awg100m/3devices 150m/2devices 250m/ldevice
18awg300m/6devices18awg100m/6devices 150m/4devices 200m/3devices 300m/2devices

Note: When using different cable, the maximum number of devices can connect to NS-2 under the different maximum distances which can refer to the above table. For example, when using a 24awg cable, if the farthest distance is 100m, the maximum number of devices connect to NS-2 is 6.

Notice Information
Information contained in this document is believed to be accurate and reliable at the time of printing. This document is subject to change without notice, any update to this document can be viewed on Akuvox’ s website: http://www.akuvox.com © Copyright 2022 Akuvox Ltd. All rights reserved.

Akuvox NS 2 Network Switch - QR codehttp://www.akuvox.com/

AKUVOX (XIAMEN) NETWORKS CO., LTD.
ADD: 10/F, NO.56 GUANRI ROAD, SOFTWARE PARK II, XIAMEN 361009, CHINA
Akuvox NS 2 Network Switch - Barcode

Documents / Resources

Akuvox NS-2 Network Switch [pdf] Installation Guide
NS-2 Network Switch, NS-2, Network Switch, Switch

References

Leave a comment

Your email address will not be published. Required fields are marked *