KH KHX Circular Sound Attenuates

Specifications

  • Models: KHX with inner core and KH without inner core
  • Mounting flange with threaded insert
  • Mineral wool with protection against erosion
  • Connecting neck
  • Perforated inner casing
  • Connection TYPE A and TYPE B available

Product Usage Instructions

Installation

  1. Ensure the HVAC system is turned off before installation.
  2. If required, connect optional connection flanges to the
    attenuator to connect it directly to the fans.
  3. Mount the circular sound attenuator securely in the desired
    location within the duct system.

Maintenance

Regularly check the sound attenuator for any signs of damage or
blockages. Clean or replace as necessary to maintain optimal
performance.

Safety Precautions

  • Always follow proper safety procedures when handling the
    circular sound attenuator.
  • Avoid placing any objects on or near the attenuator that could
    obstruct airflow.

FAQ

Q: Do I need any additional components for installation?

A: Optional connection flanges may be required to connect the
attenuator directly to the fans. Contact our technical department
for more information.

Q: How do I determine the correct size for my HVAC system?

A: Refer to the nominal size specifications provided in the user
manual to select the appropriate size based on your system
requirements.

“`

CIRCULAR SOUND ATTENUATORS
KH & KHX

www.airtechnic.gr www.facebook.com/Airtechnic.gr www.instagram.com/airtechnic.chatzoudis

V. 4

Circular Sound Attenuators

AIRTECHNIC circular sound attenuators KH and KHX are designed for installation in HVAC systems with circular fans and ducts, in order to reduce the fan noise. Optional connection flanges might be required in order to connect the attenuator directly to the fans (for more information please contact our technical department).

TECHNICAL SPECIFICATIONS KH / KHX

2 models: KHX with inner core and KH without inner core.
Casing in galvanised steel with nominal thickness 0,8 mm for diameters up to Ø1.250 mm and 1,0 mm for larger diameters. Possible to produce casing with any thickness, in stainless steel or copper, under request. 2 connection options: Type A with mounting flange with threaded insert and Type B with connecting neck. Sound absorbent material: Mineral wool, 70 Kg/m3 density, fire resistance M0, protected against fabric erosion. Inner casing from perforated metal sheet. Acoustic data tested in accordance to EN ISO 7235. Holes and connectiong neck are manufactured according to Eurovent Standards. KHX models are manufactured with an inner core for increased attenuation requirements. Standard lengths: [1 x D], [1,5 x D] and [2 x D]. Possible to produce at any length, under request.
Mounting flange with threaded insert

Mineral wool with protection against erosion
Connecting neck

Perforated inner casing

Connection TYPE A
L

Connection TYPE B
L

D

EF

KH

D

NOMINAL SIZE
250 300 315 350 355 400 450 500 560 600 630 650 700 710 750 800 850 900 1.000 1.120 1.200 1.250 1.300 1.400 1.500 1.600 1.700 1.800 1.900 2.000

Ø D (mm)
250 300 315 350 355 400 450 500 560 600 630 650 700 710 750 800 850 900 1.000 1.120 1.200 1.250 1.300 1.400 1.500 1.600 1.700 1.800 1.900 2.000

Ø E (mm)
390 440 455 490 495 540 610 660 720 760 790 810 860 870 950 1.000 1.050 1.100 1.200 1.320 1.400 1.450 1.500 1.600 1.700 1.800 1.900 2.000 2.100 2.200

Y

EF

KHX

Ø F (mm)
280 340 355 390 395 450 500 560 620 660 690 710 760 770 810 860 920 970 1.070 1.190 1.270 1.320 1.370 1.470 1.580 1.680 1.780 1.880 1.980 2.080

N holes
4 8 8 8 8 8 8 12 12 12 12 12 16 16 16 16 16 16 16 20 20 20 20 20 24 24 24 24 24 24

DIMENSIONS

Ø holes
11 11 11 11 11 12 12 12 12 12 12 12 12 12 12 12 15 15 15 15 15 15 15 15 15 15 15 15 15 15

Ø insert
M8 M8 M8 M8 M8 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M10 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12

Ø Y (mm)
120 140 140 200 200 200 245 245 295 295 295 295 380 380 380 380 380 380 650 650 650 650 650 650 650 650 650 650 650 650

2 T: +30 211 70 55 500 / / +30 2311 82 40 00

1 x D 250 300 315 350 355 400 450 500 560 600 630 650 700 710 750 800 850 900 1.000 1.120 1.200 1.250 1.300 1.400 1.500 1.600 1.700 1.800 1.900 2.000

LENGTH L (mm) 1,5 x D 375 450 472,5 525 532,5 600 675 750 840 900 945 975 1.050 1.065 1.125 1.200 1.275 1.350 1.500 1.680 1.800 1.875 1.950 2.100 2.250 2.400 2.550 2.700 2.850 3.000

2 x D 500 600 630 700 710 800 900 1.000 1.120 1.200 1.260 1.300 1.400 1.420 1.500 1.600 1.700 1.800 2.000 2.240 2.400 2.500 2.600 2.800 3.000 3.200 3.400 3.600 3.800 4.000

3 T: +30 211 70 55 500 / / +30 2311 82 40 00

ISO 9001:2015

ISO 14001:2015

FAN COIL UNITS

& FAN SECTIONS

THINK CLEAN

– 10 & , ..: 12132, , 211 – 70.55.500
sales@airtechnic.gr

– 4 . – , ..: 32200, 22620 – 89.006
factory@airtechnic.gr

– , ..: 57013, / 2311 – 82.40.00
thessaloniki@airtechnic.gr

Documents / Resources

AIRTECHNIC KH KHX Circular Sound Attenuates [pdf] Installation Guide
KH, KHX, KH KHX Circular Sound Attenuates, KH KHX, Circular Sound Attenuates, Sound Attenuates

References

Leave a comment

Your email address will not be published. Required fields are marked *