Aideepen YS-RT220K Timer Delay Controller Relay
Overview
The Timer Delay Controller Relay Module (model YS-RT220K) provides adjustable power-on delay and timed automatic shutdown for a single live-line output, with an LED indicator to show running status.
Specifications
| Item | Specification |
|---|---|
| Name | 1 220V power on delay off switch |
| Model | YS-RT220K |
| Control channels | 1 single live line output |
| Power supply voltage | AC 110–250V (typical: 220V) |
| Output voltage | AC 220V (consistent with the supply voltage) |
| Output current | 7A (resistive load) |
| Timer | 180 min adjustable (9 stop options available) |
| Output type | 220V power single live line output |
| Output power | Incandescent lamp |
- Timer Delay Controller Relay AC 110V 220V Power-ON Relay Module Voltage Output 180min Adjustable Switch Power Supply.
Features:
- High quality shell, dustproof and flame retardant.
- With LED indicator light, show running status.
- 9 stops are optional, you can choose according to your own needs.
- Simple operation, can be timed automatic shutdown
- 220V power single live line output, widely used, such as exhaust fan, engine, cooling fan, germicidal lamp, humidifier, heater and so on.
Product parameters
- Name: 1 220V power on delay off switch
- Model: YS-RT220K
- Control channels: 1 single live line output
- Power supply voltage: AC110-250V (Typical value: 220V)
- Output voltage: AC220V (consistent with the supply voltage)
- Output current: 7A (resistive load)
- Output power: incandescent lamp <1200W energy-saving lamp <250W Standby power consumption: <12MA
- Power consumption: 43MA
- Size: 50x35x22mm
Interface definition:
- Red line: The input port is connected to a 220V live cable
- Green wire: The input port is connected to 220V neutral wire
- Yellow line: 220V live line at the output
- Working principle: After the switch is energized to 220V, the switch will open, and the output of 220V live wire will supply power to the electrical appliance. After time delay, the switch will close and the output will stop, thus the electrical appliance will stop
- working.
Purpose of work
- 1. Exhaust fan, motor, cooling fan, germicidal lamp, humidifier, heater and other electrical appliances automatically shut down.
- 2. After the exhaust fan switch of kitchen, bathroom, toilet and bedroom is closed, the exhaust fan will automatically shut down after continuing to work for a period of time (combined with the double switch to realize the power off delay shutdown function — refer to wiring diagram 3).
- Note: 1. When the switch delay time is up, the indicator will blink.
When the delay time is up, disconnect the power supply for more than 2 seconds and restart it after the remaining power is used up
Use operation process
Delay time comparison table
- Note: The neutral and live wires cannot be
- connected reversely or the yellow wire has Original sno output.
- (No live wiring, and installation shall be car- ried out by professionals)
Interface definition
- Red wire: the input port is connected with 220V live wire
- Green line: input port is connected to 220V zero line
- Yellow wire: 220V live wire at the output
Common wiring diagram 1: After the plug is plugged in, the appliance starts to work and stops working after a delay
- After connecting the wires according to the drawing, you can plug the live wire plug without dividing the zero wire
- How to use: Plug in the power plug (power on), the time delay device will automatically open and enter the delay state, and will automatically close after the scheduled time. Next time delay: pull out/plug in the power plug first, and the time will be repeated. If it is necessary to close it in advance in the middle of the process, just unplug the power plug.
- Wiring method: red hot wire in, yellow hot wire out and green zero wire in common.
Size

Feature
Common Wiring Diagram 2: After the switch is turned on, the appliance starts to work and stops working after a delay The zero line goes directly to the time delay device and the lamp without any switch.

- How to use: Turn on the mechanical switch (power on), the time delay device will automatically open and enter the delay state, and will automatically close after the scheduled time. Next time delay: turn off/turn on the mechanical switch first, and the lime will be repeated. If it is necessary to close in advance midway, the mechanical switch can be directly turned off.

- Common wiring diagram 3: The electrical appliance is closed after a delay after the dual switch control is powered off Zero line: directly to the time delay device and the lamp without any switch.

Power off/power off delay switch connection
- First, select the delay time of the switch, and select different delay parameters clockwise according to the scale with the Phillips screwdriver.
- Disconnect the power supply of the device and other power sources connected with electrical appliances to avoid electric shock.
- Connect the circuit according to the wiring method in the figure above, and wrap the electric tape.
- 4, check the connection is no problem, switch on the power, with the electrical equipment to work normally, the time will be automatically closed, the indicator light flashing.
Product list
- 1X delay switch relay

Troubleshooting
| Problem | Possible Cause | Solution |
| Module fails to power on | Power input polarity is reversed or voltage is insufficient | Check DC power supply connections, verify polarity (V+ and V-), and ensure voltage matches module specifications |
| Relay does not trigger upon signal input | Trigger signal line is loose or trigger voltage level is incorrect | Inspect trigger wiring contacts and ensure the signal matches the high or low trigger requirements |
| Time delay duration is inaccurate | Potentiometer or jumper range setting is misconfigured | Re-adjust the onboard potentiometer dial and verify that jumper caps are set to the correct timing scale |
| Connected load does not receive power when relay activates | Incorrect terminal wiring on the relay output block | Ensure load wiring is connected across Common (COM) and Normally Open (NO) terminals rather than Normally Closed (NC) |
| Relay resets unexpectedly or chatter occurs | Power supply voltage drops during relay coil activation | Use a stable power supply with sufficient current capacity to handle the relay activation load |