Aideepen 220v Ac Microcomputer Time Controller Module

Specifications
- Product Name: XYZ Electric Kettle
- Capacity: 1.7 liters
- Power: 1500 watts
- Material: Stainless Steel
- Features: Auto shut-off, Boil-dry protection, Cordless design
DC 12V 24V AC 110V 220V Digital Cycle Timer Delay Relay Board Module Microcomputer Time Controller Delay Relay Module Switch

- Timing range: 00:00~99:59 0000~9999 S
- Power : DC12V/20A /240W (Max) DC24V/20A/480W (Max) AC110V~220V /10A/2200W (Max)
- Product size: 67×45×34mm
- Hole size: 63×42mm
- product weight: 58g(12V/24V) 63g(110~220V)

WIRING

Warning
This product is a direct output controller. Please connect the load before turning on the power Avoid accidents!

Display interface

Working status

MICROCOMPUTER TIME CONTROLLER
1.37″ LCD

SIMPLE OPERATION
Sensitive buttons for easy operation and durability

- After setting the data, you must wait 6 seconds, 6s post modules automatically save memory set data.
- Press SET key once to enter the time setting mode, the red LED flashes, press the key to increase or decrease the setting time T1.
- After setting time T1, short press the SET key again, the green LED flashes, and the time is set by pressing the key Time T2, T2 time setting is completed, press SET key again, the system will automatically save the memory setting time or wait for 6s, 6s module will automatically save the data memory.
- Long press SET, enter parameter setting mode. There are two sets of parameters for the user to select P0, P1. Short press SET in the current mode to switch between P0 and P1.
- In P0 parameter can be set by pressing the key to adjust their own timing mode. In the P1 parameter can be set by adding and subtracting keys work mode.
- P0–0:T1 Timing mode is second.
- P0–1: T1 timing mode is minutes.
- P0–2:T1 Timing Time mode is hour.
- P1–0: Delay T1 time, relay pull(T1 timer)
- P1–1: Relay release after T1 time delay (T1 timer)
- P1–2: Delay T1 time, relay pull(T1 timer), and then relay release after T2 time delay(T2 timing),then it is finished.
- P1–3: Relay release after T1 time delay(T1 timer), then delay T2 time, relay pull(T2 timing),then it is finished.
- P1–4: Delay T1 time, relay pull(T1 timer), and then relay release after T2 time delay(T2 timer), cycling.
- P1–5: Relay release after T1 time delay(T1 timer), then delay T2 time, relay pull(T2 timer), cycling.

- Product Name: T2302 Time Digital Relay
- Working voltage: DC 5V / 12V / 24V
- Relay: 20A
- Timing range: 0-999 seconds, 0-999 minutes, 0-999 hours
- Working mode: delay on, delay off, timing on, timing off, cycle on, cycle off
- Size: 45.5mm × 26.5mm × 30mm
- Weight: 25g
Product Instructions:
Please pay attention for your first use. You need wait 6s after your setting data, the module will save the date you have set after 6s.
Short press button SET: If you start the time setting mode , Nixie tube will blink. You could adjust the time T1 and T2 by button+ and button-. Please wait 5s after your setting date, the module will save the date you have set after 5s .
Long press button SET: if you start the parameter setting mode. There are two group parameter for your choice : P0 and P1. You could switch P0 or P1 by short press SET. Under the parameter P0 and P1,you could set the timing mode by the button+ and button-.
- P0–0: Timing time mode : 0—999s.
- P0–1: Timing time mode : 0—999min.
- P0–2: Timing time mode : 0—999h.
- P1–0: The relay will connect after you delay the T1 time .
- P1–1: The relay will disconnect after you delay the T1 time.
- P1–2: The relay will connect after you delay the T1 time first, Then the relay will disconnect after you delay the T2 time , it finish.
- P1–3: The relay will disconnect after you delay the T1 time first, Then the relay will connect after you delay the T2 time , it finish.
- P1–4: The relay will connect after you delay the T1 time first, Then the relay will disconnect after you delay the T2 time , it is cyclic.
- P1–5: The relay will disconnect after you delay the T1 time first, Then the relay will connect after you delay the T2 time , it cyclic.
- Example: A customer needs 10 seconds to start up and 20 seconds off. Setup is as follows:
- T1 set time 10, T2 set time 20
- P0 — 0 (T1 time range is seconds)
- P1–5 (timer work mode)
Package Included:
1 x T2302 12V Timing Delay Timer Relay Module Digital LED Dual Display Cycle 0-999 Hours 20A Time Digital Relay Drop Ship