1. Introduction
The GEYA THC-822 Conversational Programmable Timer introduces innovative design concepts, utilizing advanced international hardware and software technologies. It is designed for simple and intuitive operation, allowing users to complete all settings step-by-step through the display screen instructions.
Key features include a large LCD display that directly shows year, month, day, week, time, and supports arbitrary ON/OFF settings for 24 hours or a week. The device features simple four-button operation, guiding the user through necessary settings without requiring complex programming knowledge. It also supports manual ON/OFF, permanent ON/OFF, and offers six national languages: English, Portuguese, Italian, Spanish, German, and French.
Video: Overview of GEYA products and manufacturing process.
2. Specifications
| Feature | Description |
|---|---|
| Product Name | Conversational Programmable Timer |
| Model Number | THC-822 Timer Switch |
| Brand | GEYA |
| Theory | Digital |
| Type | Mini |
| Use | Timer Switch |
| Origin | Mainland China |
| Certification | CE |
| Power Supply | AC220V+10%~-15% 50/60Hz, AC110V±10% 50/60Hz (customizable) |
| Power Consumption | Max 7.5VA |
| Rated Current | 16A |
| Contact Capacity | 16A AC250V cos φ =1, 10A AC250V cos φ =0.6 |
| Switching Contact | 2 Changeover Switch (2NO2NC) |
| Control Way | THC822 top 2way |
| Mounted | Din Rail |
| Display | LCD |
| Operation Keys | Four operation keys plus a reset key |
| Timing Benchmark | High quality quartz shock timing |
| Timing Accuracy | ±1 second per day (at 20°C) |
| Max Setting Procedure | 44 |
| Min Setting Time | 1 minute |
| Min Pulse Setting Time | 1 second |
| Max Cycle Programs | 18 |
| Storage Power | Lithium battery (approx. 4 years at 20°C) |
| Ambient Temperature | -10°C ~ +50°C |
| Storage Temperature | -20°C ~ +65°C |
| Dimensions (H x W x D) | 86mm x 35.5mm x 65.5mm |
| Languages Supported | English, Portuguese, Italian, Spanish, German, French |

Image: Technical Parameters and Dimensions of THC-822 Timer.

Image: Detailed Technical Specifications Table.
3. Installation
The THC-822 timer is designed for Din Rail mounting.
3.1 Wiring Diagrams
Ensure all power is disconnected before attempting any wiring. Consult a qualified electrician if you are unsure about any steps.

Image: Wiring Diagram for Single Load (AC220V). Connect Live (L) to terminal L, Neutral (N) to terminal N. Load is connected between L and C1 (common) and U1 (normally open).

Image: Wiring Diagram for Two Independent Loads (AC220V). Note: This is a special case, for reference only. Two loads work separately and independently. Each load is connected between Live (L) and its respective common (C1 or C2) and normally open terminal (U1 or U2).
3.2 Security Features
The PC transparent cover can be opened to add a lead seal, enhancing security against tampering.

Image: Diagram showing transparent cover and lead seal option.
4. Initial Setup
When using the timer for the first time, press the 'RES' button to reset the device.

Image: Instructions for choosing language and setting the date.
4.1 Language Selection
- After pressing 'RES', 'ENGLISH' will flash on the display.
- Use the '+' or '-' keys to cycle through the available languages (English, Portuguese, Italian, Spanish, German, French).
- Press 'OK' to confirm your selection.
4.2 Setting the Date and Time
- After selecting the language, the display will show '2007'.
- Use the '+' or '-' keys to adjust the year, then press 'OK' to confirm.
- Repeat this process for month, day, hour, and minute. The setting procedure is the same for each.
- To reset only the date without affecting other settings, press the 'Menu' button twice from the general screen (display shows 'DAT/TIM'), then press 'OK'. Proceed to enter the year, month, day, hour, and minute.
4.3 Summer/Winter Time Settings
- From the general screen, press 'Menu' button twice (display shows 'DAT/TIM'), then press 'OK' to enter the date setting function. Continue pressing 'OK' until 'SUM/WIN' is displayed.
- Press 'OK' to enter the summer/winter time function. The display will show 'NO SU/WI' or 'WITH S/W'.
- Use the '+' or '-' keys to change the display:
- 'NO SU/WI': If no summer/winter time function is needed, press 'OK' to exit.
- 'WITH S/W': Press 'OK'. The 'EUROPE' option will be displayed. Use '+' or '-' to select from the 5 available options (EUROPE, GB/P, SF/GR/TR, USA/CAN, FREE). Press 'OK' to confirm your choice.
- To manually adjust for summer time, press 'C+' and 'MANUAL' together. After 3 seconds, the hour will automatically increase by one hour, and 'SUMMER' will be displayed. To revert, press these two buttons again; the hour will decrease, and 'SUMMER' will disappear.
5. Programming
The THC-822 timer supports up to 44 ON/OFF programs, 44 pulse programs, and 18 cycle programs per 24 hours or a week.

Image: Summer/Winter Time and Program Setting Instructions.
5.1 ON/OFF Program Setting
- From the general screen, press the 'Menu' button (display shows 'PROGRAM'), then press 'OK' to enter the ON/OFF time course sequence setting.
- The display will show 'NEW PROG'. Press 'OK'. 'FREE 44' will be displayed, indicating the number of available programs.
- 'CHANNEL 1' will be displayed. Use '+' or '-' to select 'CHANNEL 2' if needed. Press 'OK'.
- 'TIME ON' will appear (setting contact ON state). Use '+' or '-' to change to 'TIME OFF' (setting contact OFF state). Press 'OK'.
- Enter the desired time (hour, minute) using the '+' or '-' keys. Press 'OK' after each entry.
- Set the desired day(s) of the week using the '+' or '-' keys. Press 'OK' after selection.
- If 'COPY' appears, press 'OK' to copy this program to another date, or '+' to skip copying.
- Select 'STORE' and press 'OK' to save and proceed to 'NEW PROG' for the next program.
- To exit program setting, press 'Menu' after completing all programs.
5.2 Pulse Program Setting
- Continuously press 'Menu' until 'PULSE' is displayed. Press 'OK'.
- 'NEW PROG' will be displayed. Press 'OK'. 'FREE 44' will be displayed.
- 'CHANNEL 1' will be displayed. Use '+' or '-' to select 'CHANNEL 2' if needed. Press 'OK'.
- 'TIME ON' will appear. Use '+' or '-' to change to 'TIME OFF'. Press 'OK'.
- 'PULS SEC' will be displayed. Use '+' or '-' to set the pulse width (1 to 59 seconds). Press 'OK'.
- Set the pulse start time (hour, minute) as needed.
5.3 Cycle Program Setting
- Continuously press 'Menu' until 'CYCLE' is displayed. Press 'OK'.
- 'NEW PROG' will be displayed. Press 'OK'. 'FREE 18' will be displayed, indicating up to 18 cycle programs.
- 'CYCLE ON' will be displayed. Enter the start hour and minute. Set the day(s) of the week.
- After 'PULS MIN', enter 'PULS SEC', 'PAUSE MIN', 'PAUSE SEC' using '+' or '-' keys. Press 'OK' after each entry.
- After completing the ON cycle settings, 'CYCLE OFF' will be displayed. Set the end hour and minute. Set the day(s) of the week.
- Press 'OK' to save the program.
5.4 Random Program Setting
- Continuously press 'Menu' until 'MANUAL' is displayed. Press 'OK'.
- Use the '+' or '-' keys to select 'RANDOM'. Press 'OK' to confirm.
- The random execution time can be set between approximately 10 to 120 minutes.
- To cancel, press 'Menu' until 'MANUAL' is displayed, press 'OK', use '+' or '-' to select 'RAND OFF', then press 'OK'.
5.5 Holiday Program Setting
- Continuously press 'Menu' until 'MANUAL' is displayed. Press 'OK'.
- When 'HOLIDAY' is displayed, press 'OK' to confirm. 'START' will be displayed. Enter the year, month, and day using '+' or '-'.
- 'END' will be displayed. Enter the end year, month, and day. Press 'OK' to confirm.
- To cancel, press 'Menu' until 'MANUAL' is displayed, press 'OK', use '+' or '-' to select 'HOLIDAY', then press 'OK', select 'CLEAR', and press 'OK'.
6. Operation

Image: Detailed Display Explanation of THC-822 Timer.
6.1 Display Indicators
- Black Stripe: Indicates contacts are ON 24 hours a day.
- AUTO: Timer operates ON/OFF as programmed.
- Clock Icon: Indicates manual permanent ON or OFF status ('PERM ON' or 'PERM OFF').
- Hand Icon: Indicates a valid manual ON or OFF state ('OVERRIDE').
- Sun Icon: Daylight saving time is active.
- Snowflake Icon: Winter time is active.
- Triangle Icon: Indicates the day of the week.
- '+' Key: Used to add value or change options.
- '-' Key: Used to reduce value or change options.
- 'Res' Key: Resets date/time.
- 'OK' Key: Confirms selection or enters program key.
6.2 Manual ON/OFF (Override)
This function allows you to manually change the output state without affecting the automatic function of subsequent programs.
- Continuously press 'Menu' until 'MANUAL' is displayed. Press 'OK'.
- 'CHANNEL 1' will be displayed. Use '+' or '-' to select 'CHANNEL 2' if needed.
- Use the '+' or '-' keys to select 'OVERRIDE'. Press 'OK'.
- To cancel, press 'Menu' until 'MANUAL' is displayed, press 'OK', then select 'CLEAR', and press 'OK'.
6.3 Permanent ON/OFF (PERM ON/OFF)
This function allows you to manually change the output state, which remains persistent until manually changed again.
- Continuously press 'Menu' until 'MANUAL' is displayed. Press 'OK'.
- 'CHANNEL 1' will be displayed. Use '+' or '-' to select 'CHANNEL 2' if needed.
- Use the '+' or '-' keys to select 'PERM ON/OFF'. Press 'OK'.
- To cancel, press 'Menu' until 'MANUAL' is displayed, press 'OK', then select 'CLEAR', and press 'OK'.
6.4 Power Saving Function
If no button is pressed for 10 minutes while the timer is in the language screen or has a set date/time/procedures, the screen will automatically close to save battery power. Press any button to restore the screen.
7. Maintenance
- The internal lithium battery can supply power for approximately 4 years at room temperature (20°C).
- Avoid using the timer in dusty, corrosive gas, direct sunlight, or rainy environments.
- Store the device within the specified rated voltage, temperature, and humidity ranges.
- Dispose of electrical products responsibly at designated recycling facilities, not with household waste.
8. Troubleshooting
8.1 LCD Screen Issues
- No inscription on LCD screen: If the LCD screen is blank or unreadable, check the internal battery. The lithium battery has a lifespan of about 4 years. If it's older, the battery may need replacement. Contact GEYA support for assistance with battery replacement.
8.2 Forgotten Password (Key Lock)
If you have set a key lock password and forgotten it, you will need to contact GEYA for assistance to reset the device.
8.3 Timer Reverts to Time Display
If no settings are made within 10 minutes during setup, the controller will automatically revert to the time display mode to save power. This is normal behavior.
9. User Tips
- First Use: Always press the 'RES' button to turn on the timer when using it for the first time.
- Applications: This timer is suitable for controlling electric thermos, water pumps, and other electrical appliances.
- Minimum Time Interval: The minimum setting time for programs is 1 minute, and for pulse programs, it is 1 second.
- Full Manual: If you require a more detailed manual, please refer to the PDF document mentioned in the support section or contact GEYA directly.
10. Warranty and Support
For detailed instructions and further support, please refer to the official user manual (PDF) available at: GEYA THC-822 User Manual (PDF).