MYPIN FH4-CRNB

Contents

Mypin FH4-CRNB Digital Counter Meter

User Manual

Model: FH4-CRNB | Brand: MYPIN

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the Mypin FH4-CRNB Digital Counter Meter. This device is a versatile industrial counter designed for precise counting applications, featuring a wide voltage input range and relay output.

For a complete PDF version of the user manual, please refer to the official document: Mypin FH4-CRNB User Manual (PDF).

2. Product Overview

2.1. Front Panel

Front view of the Mypin FH4-CRNB Digital Counter Meter
Figure 2.1: Front view of the Mypin FH4-CRNB Digital Counter Meter, showing the digital display and control buttons.

The front panel features a dual digital display for measured and preset values, along with indicator lamps and control keys.

2.2. Rear Panel and Wiring

Rear view of the Mypin FH4-CRNB Digital Counter Meter with wiring diagram
Figure 2.2: Rear view showing the terminal block and integrated wiring diagram for power, input, and relay output.

The rear panel provides access to the terminal block for electrical connections. A detailed wiring diagram is printed on the unit for easy reference, indicating connections for power (90-260V AC/DC), input signals (INA, INB, GND), reset (RST), and relay outputs (OUT1 NC/NO).

2.3. Side and Bottom Views

Side view of the Mypin FH4-CRNB Digital Counter Meter
Figure 2.3: Side view of the counter meter, showing the compact design.
Bottom view of the Mypin FH4-CRNB Digital Counter Meter terminals
Figure 2.4: Bottom view highlighting the screw terminals for secure wiring connections.

3. Specifications

Table of technical specifications for Mypin FH4-CRNB
Figure 3.1: Technical Specifications.
FeatureDescription
Input SignalsPulse signal: square wave and sine wave (5V ≤ H ≤ 30V, 0V ≤ L ≤ 2V, up edge active). Input impedance: ≥10KΩ.
Counting Speed30/5000 CPS
Counting Range-199999 to 999999 (dependent on display digit configuration)
Preset Range0.00001 to 999999 (dependent on display digit configuration)
Auxiliary Power24V/12VDC ± 10%, 40mA max
Output TypeRelay contact output
Contact Relay Capacity250V AC/3A or 30V DC/5A
Operation Environment0~50°C, 35~85% RH (non-condensing)
Parameter Saving Time10 years
Insulation Resistance≥10MΩ
Consumption≤5W
Contact EdgeUp edge Active
Power SupplyDC 24V ±15% or 80-265V AC/DC

4. Installation

The FH4-CRNB counter meter is designed for panel mounting. Ensure the mounting cutout matches the dimensions provided below for secure installation.

Mounting dimensions for FH series counters
Figure 4.1: Mounting dimensions and ordering code structure.

4.1. Mounting Dimensions (FH4 Model)

ModelA (mm)B (mm)L (mm)C (mm)D (mm)
FH448488045 ± 0.545 ± 0.5
FH7727210067.5 ± 0.567.5 ± 0.5
FH848968045 ± 0.591 ± 0.5

General Installation Steps:

  1. Prepare the panel cutout according to the dimensions for your specific model (e.g., 45x45mm for FH4).
  2. Insert the counter meter into the cutout from the front.
  3. Secure the unit using the provided mounting brackets from the rear of the panel.
  4. Ensure the unit is firmly seated and flush with the panel surface.

5. Wiring Diagram

Proper wiring is crucial for the safe and correct operation of the counter meter. Refer to the diagram below and the label on the rear of the device for all connections.

Detailed wiring diagram for Mypin FH4-CRNB Digital Counter Meter
Figure 5.1: Wiring Diagram. Connect power, input signals, and relay outputs as shown.

Key Connections:

  • Power Supply (90-260V AC/DC): Connect to the designated terminals. Ensure power is off during wiring.
  • Input Signals (INA, INB, GND): Connect your pulse signal source (e.g., switch, encoder) to these terminals. INA and INB are typically for counting inputs, and GND is for common ground.
  • Reset (RST): Connect a momentary switch or control signal to this terminal for resetting the counter.
  • Auxiliary Power (24V): An auxiliary 24V output may be available for powering external sensors or components.
  • Relay Output (OUT1 NC/NO): These terminals provide normally closed (NC) and normally open (NO) contacts for controlling external devices based on the counter's preset value.

WARNING: Always disconnect power before performing any wiring to prevent electric shock and damage to the device.

6. Operation

The Mypin FH4-CRNB features an intuitive front panel for monitoring and control.

Front panel layout and button functions for Mypin FH4-CRNB
Figure 6.1: Front Panel Layout and Key Functions.

6.1. Display Elements

  • Measured Value (PV): The upper display shows the current count or measured process value.
  • Preset Value (SV): The lower display shows the target count or setpoint.
  • Indication Lamps:
    • OUT1/OUT2: Indicate the status of the relay outputs.
    • BT: Batch display lamp.
    • SV2: Indicates the second preset value is active (for models with dual presets).

6.2. Control Keys

  • SET Key: Used to enter parameter setting mode, navigate through parameters, and confirm selections.
  • <</Rst Key: Functions as a shift key during parameter setting (to move cursor) and as a reset key to clear the current count.
  • Up Arrow Key (↑): Used to increment values or scroll through options in setting mode.
  • Down Arrow Key (↓): Used to decrement values or scroll through options in setting mode.

6.3. Basic Operation

  1. Power On: Connect the device to the specified power supply (80-265V AC/DC or 24V DC). The display will light up.
  2. Setting Preset Value:
    • Press the SET key to enter parameter setting mode.
    • Use the <</Rst key to select the digit you wish to change.
    • Use the Up or Down arrow keys to adjust the value of the selected digit.
    • Press SET again to confirm the preset value and move to the next parameter, or hold SET to exit setting mode.
  3. Resetting the Counter: Press the <</Rst key (short press or long press, depending on configuration) to reset the measured value to zero.
  4. Counting: Once configured, the device will count pulses received through the input terminals (INA, INB). When the measured value reaches the preset value, the relay output will activate according to its programmed function.

7. Safety Precautions

  • Always ensure the power supply is disconnected before installation, wiring, or maintenance to prevent electric shock.
  • Do not disassemble or modify the device. Unauthorized modifications can lead to malfunction, electric shock, or fire.
  • Install the device in a dry, well-ventilated environment, away from direct sunlight, high temperatures, excessive humidity, and corrosive gases.
  • Ensure all wiring connections are secure and correct according to the wiring diagram. Loose connections can cause intermittent operation or damage.
  • Use appropriate wire gauges for power and output connections to handle the rated current.
  • If any abnormality is detected (e.g., smoke, unusual smell, abnormal operation), immediately disconnect power and contact qualified personnel.
  • This device is intended for industrial use. Ensure it is used within its specified operating conditions.

8. Maintenance and Care

  • Cleaning: Wipe the exterior of the device with a soft, dry cloth. Do not use abrasive cleaners, solvents, or water directly on the unit.
  • Inspection: Periodically check wiring connections for tightness and signs of wear or damage. Ensure the mounting is secure.
  • Environmental Conditions: Regularly verify that the operating environment remains within the specified temperature and humidity ranges.
  • Parameter Backup: While the device has a 10-year parameter saving time, it is good practice to record critical settings for future reference.

9. Troubleshooting

This section provides general guidance for common issues. For more complex problems, consult the full PDF manual or contact technical support.

  • No Power/Display Off:
    • Check the power supply connections and ensure the voltage is within the specified range (80-265V AC/DC or 24V DC).
    • Verify that the power source is active.
  • Counter Not Counting:
    • Check the input signal connections (INA, INB, GND).
    • Ensure the input signal type and voltage levels match the device specifications (5V ≤ H ≤ 30V, 0V ≤ L ≤ 2V).
    • Verify that the input sensor or switch is functioning correctly.
    • Check the counting speed setting; if the input pulses are too fast for the current setting, some counts may be missed.
  • Relay Output Not Activating:
    • Verify that the preset value (SV) is correctly set.
    • Ensure the measured value (PV) has reached or exceeded the preset value.
    • Check the relay output wiring (OUT1 NC/NO) to the external device.
    • Confirm the output mode settings in the device parameters.
  • Incorrect Count:
    • Review the input signal characteristics for noise or bouncing that might cause false counts.
    • Check the input mode settings (e.g., single-ended, differential).
    • Ensure the counting direction is correctly configured if applicable.

10. User Tips

No specific user tips were available from reviews or Q&A for this product. General tips for digital counters include:

  • For high-speed counting applications, ensure your input sensor and wiring are optimized to prevent signal degradation.
  • When setting parameters, use the shift key to quickly navigate between digits for faster input.
  • Consider using shielded cables for input signals in noisy industrial environments to minimize interference.

11. Frequently Asked Questions (FAQ)

No specific FAQ content was available from Q&A data for this product.

For common questions regarding digital counters, please refer to the comprehensive PDF manual linked in the introduction.

12. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the documentation included with your purchase or contact the manufacturer/seller directly.

Always provide your product model (FH4-CRNB) and serial number (if applicable) when seeking support.