1. Introduction
The JUNTEK PSG9080 is a programmable function/arbitrary waveform signal generator designed for a wide range of applications including education, research and development, production, and testing. It features dual-channel output, a frequency range up to 80MHz, and various modulation, frequency sweep, measurement, and programming functions. The instrument is equipped with a 3.5-inch high-resolution color LCD screen for an enhanced visual experience.
This manual provides detailed instructions for setting up, operating, maintaining, and troubleshooting your PSG9080 signal generator.

Figure 1: JUNTEK PSG9080 Programmable Signal Generator
2. Package Contents
Please check the package carefully upon receipt to ensure all items are present and undamaged:
- 1 x PSG9080 Signal Generator
- 1 x Power Cable
- 1 x BNC Male Plug Test Lead
- 1 x USB Data Cable
- 1 x BNC to Alligator Clips Test Lead
- 1 x Quick Guide

Figure 2: Package Contents
3. Setup
3.1 Initial Power-On and Language Selection
- Connect the power cable to the AC power socket on the rear panel of the PSG9080 and plug it into a suitable power outlet.
- Press the power button on the front panel to turn on the instrument.
- Upon startup, the device will enter the language selection interface. Use the navigation buttons or knob to select 'English' and confirm.
3.2 Physical Connections
The PSG9080 features various input and output connectors on its front and rear panels:
- Front Panel: Signal input connectors (INPUT) and signal output connectors (CH1 OUT, CH2 OUT).
- Rear Panel: TTL Ext. (TTL Extension), DC5V (USB power input), USB (for PC connection), SYNC IN/OUT, and AC Power socket.

Figure 3: Rear Panel Connections
3.3 PC Software Connection
The PSG9080 can be controlled via PC software for advanced programming and arbitrary waveform drawing. To connect:
- Download the latest PC software and communication protocol from the official website: http://68.168.132.244/PSG9000/material.html.
- Install the PC software and necessary drivers on your computer.
- Connect the PSG9080 to your computer using the provided USB data cable.
- Launch the PC software and establish a connection with the instrument.

Figure 4: Connecting to a Computer and Device Overview
4. Operating Instructions
4.1 Basic Controls
The front panel of the PSG9080 features a 3.5-inch LCD screen, function buttons, numeric keypads, and a knob for navigation and parameter adjustment.
- LCD Screen: Displays output signals, amplitude, phase, duty cycle, frequency, and various menu interfaces.
- Function Buttons: Used to access different modes and settings (e.g., MOD, MEAS, LOAD, SHIFT, SWEEP, VCO, FUNC, CH1, CH2, OUT).
- Numeric Keypads: For direct input of numerical values.
- Knob: For fine-tuning parameters and navigating menus.
4.2 Dual Channel Output
The PSG9080 can output two channels (CH1 and CH2) simultaneously. Both channels can generate the same or different function signals or arbitrary waveforms. All parameters for each channel can be adjusted independently, including a continuously adjustable phase difference from 0 to 359.9 degrees.
- Use the CH1 and CH2 buttons to select and configure each channel independently.
- The OUT key can switch between CH1 and CH2 channels at the same time.

Figure 5: Equal Performance Dual Channel Output
4.3 Waveform Generation
The generator supports various waveform types:
- Sine wave
- Square wave (1nHz-30MHz)
- Triangle wave (1nHz-50MHz)
- Pulse wave (with precisely settable duty ratio, pulse width, and cycle time)
- Rising ramp, falling ramp
- CMOS wave, DC level
- Half wave, full wave
- Positive step wave, Inverse staircase wave
- Exponential rise, exponential fall
- Lorentz pulse wave, multisonic wave, random noise wave
- Trapezoidal pulse wave, Sinker pulse wave
- 99 sets of user-defined waveforms
4.4 Modulation Function
The PSG9080 supports various modulation types, allowing you to add information from a signal source to a carrier wave. The modulated waveforms can be output in single or dual channels.
- Supported Modulation Types: AM (Amplitude Modulation), FM (Frequency Modulation), PM (Phase Modulation), ASK (Amplitude Shift Keying), FSK (Frequency Shift Keying), PSK (Phase Shift Keying), PWM (Pulse Width Modulation).
- Access modulation settings via the MOD button.

Figure 6: Modulation Interface
4.5 Frequency Sweep Function
The instrument can perform frequency sweeps, amplitude sweeps, and duty cycle sweeps. It supports both linear and logarithmic sweep modes.
- Press the SWEEP button to enter the sweep function settings.
- Configure start frequency, end frequency, sweep time, and sweep mode (Linear/Logarithmic).
4.6 Burst Function
Generate burst signals using sine, square, saw tooth, or arbitrary waves. The number of periods in a burst is continuously adjustable from 1 to 1,000,000,000.
- Access burst settings via the FUNC button and selecting the burst option.
- Trigger Modes: Manual trigger, CH2 trigger, External trigger (AC), External trigger (DC).

Figure 7: Burst Function and Trigger Modes
4.7 Voltage Control Function (VCO)
The frequency, amplitude, and duty cycle of the output can be controlled by an external analog voltage signal. This feature is widely used in industrial debugging for voltage-controlled sweeping frequency, amplitude, and duty cycle.
- Connect an external analog voltage signal to the appropriate input.
- Press the VCO button to configure the voltage control parameters.

Figure 8: Voltage Control Interface
4.8 Programmable Output
The PSG9080 allows you to formulate the type of waveform output, output time, and output sequence for automatic work. This enables complex automated testing scenarios.
- Access the programming mode via the MOD button.
- Define parameters such as mode conversion, serial number, load, time, and loop.

Figure 9: Programming Interface
4.9 Arbitrary Waveform Drawing
Utilize the provided PC software to draw and generate arbitrary waveforms. The communication protocol allows for secondary development programming, and all instrument functions can be controlled via the PC software, though standalone operation is also possible.

Figure 10: Arbitrary Waveform Generation
4.10 System Settings
The system settings menu allows configuration of various instrument parameters:
- Clear Memory
- Sound (ON/OFF)
- Brightness
- Language (English/Chinese)
- Built-in Waveforms
- Arbitrary Waveforms
- Wave Load Method (Auto/Manual)
- System Information
4.11 Personal Color Schemes
The system offers four color schemes for personalization. Navigate to the system setup, use the numeric keys and knob to select your preferred color, and press the soft key to save.

Figure 11: Personal Color Schemes
Video 1: PSG9080 Product Demonstration
5. Maintenance
5.1 Firmware Update
Firmware updates can be performed to fix bugs or implement special customization needs. To update the firmware:
- Press the corresponding soft key on the instrument to confirm entering the update mode.
- Connect the instrument to the PC with the PC software running.
- Perform a one-key firmware upgrade through the PC software.

Figure 12: Firmware Update Interface
5.2 General Care
- Keep the instrument clean and free from dust. Use a soft, dry cloth for cleaning.
- Avoid exposing the device to extreme temperatures, humidity, or direct sunlight.
- Ensure proper ventilation by not blocking the heat dissipation holes on the rear panel.
6. Troubleshooting
6.1 Common Issues and Solutions
- Issue: Missing components in the package.
Solution: Carefully check all packaging materials. If a component like the TTL extension board is genuinely missing, contact the seller for assistance. - Issue: PC software crashes or shows an error at startup.
Solution: Ensure that the correct drivers are installed for the PSG9080. Verify that the PC software is compatible with your operating system. Try reinstalling the software and drivers. - Issue: No signal output.
Solution: Check all cable connections (power, BNC cables). Ensure the correct channel (CH1/CH2) is selected and enabled. Verify that the output amplitude and frequency settings are appropriate. - Issue: Incorrect waveform displayed.
Solution: Double-check the waveform type and parameters configured on the device or via PC software. Ensure the oscilloscope or measuring instrument is correctly set up to display the signal.
7. Specifications
| Parameter | Value |
|---|---|
| Model | PSG9080 |
| Channel | 2 |
| Sine Wave Frequency | 1nHz-80MHz |
| Sampling Rate | 300MSa/s |
| Wave Length | 8192 points/channel |
| Waveform Vertical Resolution | 14 bits |
| Wave Type | Sine, Square, Pulse (duty ratio, pulse width, cycle time), Triangle, Rising/Falling Ramp, CMOS, DC Level, Half/Full Wave, Positive Step, Inverse Staircase, Exponential Rise/Fall, Lorentz Pulse, Multisonic, Random Noise, Trapezoidal, Sinker Pulse, 99 User-Defined |
| Square Wave Frequency | 1nHz-30MHz |
| Triangle Wave Frequency | 1nHz-50MHz |
| Frequency Resolution | 1nHz |
| Rise/Fall Time | ≤10nS |
| Amplitude Range | <1MHz: 2mVpp~25Vpp; 1MHz-11MHz: 2mVpp~10Vpp; 11MHz-60MHz: 2mVpp~5Vpp; 60MHz-80MHz: 2mVpp~3.6Vpp |
| Amplitude Resolution | 1mVpp |
| Amplitude Stability | ± 1% ±1mVpp (@ 1kHz, >10mVpp) |
| Amplitude Flatness | ≤10MHz: ±1%(0.1dB); 10MHz-50MHz: ±2%(0.2dB); 50MHz-60MHz: ±10%(0.9dB) |
| Offset Range | -9.99V-12.00V |
| Offset Resolution | 0.01V |
| Phase Adjustment Range | 0°-359.9° |
| Phase Resolution | 0.1° |
| Output Impedance | 50Ω (typical) |
| Modulation Type | AM, FM, PM, ASK, FSK, PSK, PWM |
| Trigger Source | Manual Burst, CH2 Burst, External Burst (AC), External Burst (DC) |
| Measurement Function | Frequency, Positive/Negative Pulse Width, Period, Duty Cycle |
| Counter Range | 0-4294967295 |
| Sweep Function | Sweep Frequency, Sweep Amplitude, Sweep Duty |
| Sweep Mode | Linear, Logarithmic |
| VCO Function | Frequency Control, Amplitude Control, and Duty Cycle Control |
| Running Mode | Debugging, Normal |
| Display Size | 3.0 - 4.9 Inches |
| Battery Included | No |
| High-concerned chemical | None |
| Certification | CE, FCC |
8. User Tips
- Check Package Contents: Always verify that all listed accessories, including any specialized boards for TTL sockets, are present in your package upon arrival. If anything is missing, contact the seller immediately.
- Software Installation: If you encounter issues with the PC software (e.g., startup errors), ensure that all necessary drivers are correctly installed and that the software version is compatible with your operating system. Reinstalling drivers and software can often resolve such problems.
- Explore Dual-Channel Capabilities: The PSG9080's dual-channel output with independent parameter control and phase adjustment is a powerful feature. Experiment with generating complex signals by combining different waveforms or phase shifts across the two channels.
- Utilize Programmable Features: For repetitive tasks or automated testing, leverage the programmable output function. This allows you to define sequences of waveforms, timings, and parameters, significantly streamlining your workflow.
- Arbitrary Waveform Design: Don't limit yourself to standard waveforms. Use the PC software to design and upload custom arbitrary waveforms for specialized applications.
9. Support
For further assistance, technical support, or to download the latest software and documentation, please visit the official JUNTEK website or the provided data download link: