1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your GlintDeer W3230 Mini Digital Temperature Controller. This versatile device is designed for precise temperature regulation in various applications, supporting both heating and cooling control modes across 12V, 24V, and 220V power supplies.
2. Safety & Warnings
- Do not use with incompatible devices or accessories to avoid affecting product performance or damaging related equipment.
- If the product shows any abnormal conditions such as smoke, unusual noises, or odors, immediately stop using it.
- This product is not food-related. Keep it away from children and avoid accidental ingestion or touching of sharp parts (if any).
- Ensure proper wiring and load connection, especially for 110V-220V, as incorrect wiring can damage the device.
3. Product Overview
The W3230 Mini Digital Temperature Controller features a clear digital display and intuitive buttons for easy operation. It displays both the real-time temperature (PV) and the set temperature (SV).
Display Indicators:
- PV (Process Value): Displays the real-time measured temperature.
- SV (Set Value): Displays the target set temperature.
- OUT Indicator Light: Blinking indicates a delay in starting cooling or heating. A steady light indicates that the relay is closed (output is active).
4. Specifications
| Feature | Specification |
|---|---|
| Power Supply | DC 12V / DC 24V / AC 110V-220V (selectable model) |
| Temperature Control Range | -55℃ to 120℃ |
| Resolution Ratio | 0.1°C (-9.9 to 99.9°C); 1°C (other ranges) |
| Display Color | Red/Blue |
| Measurement Accuracy | ±0.1°C |
| Control Accuracy | 0.1°C |
| Sensor | NTC10K Waterproof sensor |
| Output | Relay Contact Capacity 20A 12V / 10A 220V |
| Environmental Requirements | -10°C to 60°C, Humidity 20%-85%RH |
| Dimensions (L*W*H) | 79mm * 43mm * 26mm |
| Cutting Size | 73mm * 39mm |
| Sensor Wire Length | 1 meter (2-meter sensor available separately) |
5. Setup
Before connecting, ensure the power supply matches your controller model (12V, 24V, or 110V-220V AC). Incorrect voltage can damage the device. Always connect the load before applying power to the controller.
Wiring Instructions:
- Power Supply: Connect your power source (DC 12V, DC 24V, or AC 110V-220V) to the VCC+ and GND- terminals as indicated in the diagram.
- Sensor: Connect the NTC10K waterproof sensor to the S1 and S2 terminals.
- Load: Connect your heating or cooling device (load) to the relay contact terminals. For 110V-220V connections, ensure the load is properly connected to avoid burning out the product.
Important: For 110V-220V connections, a load must be used, otherwise the product will burn.
6. Operating Instructions
After proper wiring and power-on, the display will show the current measured temperature. The controller is ready for use.
6.1. Basic Temperature Setting
- Press the SET button once. The SV (set temperature) display will flash.
- Use the Up (▲) and Down (▼) buttons to adjust the desired temperature. These buttons allow for quick adjustment.
- Press the SET button again to confirm the setting and exit.
6.2. Parameter Function Description (Advanced Settings)
To access advanced settings (P0-P8), long press the SET button for 5 seconds. Use the Up (▲) and Down (▼) buttons to navigate between parameters (P0 to P8). Press SET once to enter a parameter's setting, then use Up (▲) and Down (▼) to adjust the value. Long press SET or wait 10 seconds without any button action to confirm and exit the menu.
| Parameter | Description | Range/Options |
|---|---|---|
| P0 | Cooling (C) or Heating (H) Mode | H (Heating) / C (Cooling) |
| P1 | Return Difference (Hysteresis) | 0.1 - 15°C |
| P2 | Maximum Temperature Setting Upper Limit | -55°C to 120°C |
| P3 | Minimum Temperature Setting Lower Limit | -55°C to 120°C |
| P4 | Temperature Correction | -7.0 to 7.0°C |
| P5 | Delayed Start Time | 0 - 10 minutes |
| P6 | High Temperature Alarm | -55°C to 120°C (OFF to disable) |
| P7 | Data Lock | ON / OFF |
| P8 | Restore Factory Settings | ON / OFF |
6.3. Saving Settings
To ensure your settings are retained after a power cycle, set parameter P7 to 'ON'. This will save the last configured data.
6.4. Factory Data Reset
If the internal settings become confused due to incorrect operations, you can restore the factory default settings. To do this, turn off the controller, then press and hold both the Up (▲) and Down (▼) buttons simultaneously while powering on the device. All parameters will be reset to their factory defaults.
6.5. Operation Demonstration Video
Watch this video for a visual guide on setting up and operating the W3230 temperature controller, including parameter adjustments and a temperature test.
7. User Tips
- The controller is generally easy to set up and provides a clear view of temperatures.
- When adjusting settings, the counter may spin quickly; adjust slowly or use small increments for precise control.
- The NTC10K sensor is waterproof, but the main controller unit is not. Avoid immersing the controller in water.
- Settings are typically retained after a power outage if P7 (Data Lock) is set to ON.
- This controller is suitable for applications like incubators, maintaining temperatures between specific ranges (e.g., fan on at +5°C, off at +10°C).
- For high-power loads (e.g., 3kW), consider using an intermediate relay to protect the controller's internal relay.
8. Troubleshooting
- Display shows "LL": Indicates a sensor open circuit. Check the sensor connection.
- Display shows "HH": Indicates the temperature is out of the measuring range. The thermostat will forcibly disconnect the relay.
- Display shows "---": Indicates a high temperature alarm.
- Controller heats up and turns off after an hour: This could indicate an overload. Ensure the connected load does not exceed the controller's specified relay capacity (20A for 12V, 10A for 220V). Consider using an external relay for higher loads.
- Device does not power on or function: Check all wiring connections for proper polarity and secure contact. Verify the power supply voltage matches the controller's requirements.
- Load (e.g., 220V motor) does not activate: Double-check the load wiring to the relay terminals. Ensure the controller is in the correct heating/cooling mode (P0) and the temperature settings (SV, P1) are appropriate for activation.
- Settings are lost after power cycle: Ensure parameter P7 (Data Lock) is set to 'ON' to save settings permanently.
9. Maintenance
- Keep the device clean and free from dust and moisture.
- Regularly inspect wiring for any signs of wear or damage.
- Ensure the sensor is clean and properly positioned for accurate readings.
- If the device malfunctions, attempt a factory reset (see section 6.4) before seeking further assistance.
10. Warranty & Support
For technical support or warranty inquiries, please contact the manufacturer or EU representative:
Manufacturer:
- Country: China
- Telephone: +86-13417026232
- Email: xinhui0518@163.com
- Responsible Person: Ouyanghui
EU Representative:
- eVatmaster Consulting GmbH
- Address: Bettinastr. 30, 60325 Frankfurt am Main, Germany
- Email: contact@evatmaster.com
- Telephone: +49-6995179070