GEYA GYHC Modular Contactor

Contents

GEYA GYHC Modular Contactor Instruction Manual

Model: GYHC Series

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your GEYA GYHC Modular Contactor. Please read this manual thoroughly before using the product and keep it for future reference.

GYHC Contactors are available in two versions: contactors without manual operation and contactors with manual operation. The GYHC series is designed to meet a wide range of applications, offering auxiliary control, protection, and indication functions. These modular contactors are suitable for remote control applications in alternative networks, including:

  • Lighting systems
  • Heating and ventilation systems
  • Roller shutters
  • Public hot water systems
  • Mechanical ventilation systems
  • Load-shedding of non-priority circuits

The product features a visualization window for clear indication of the on-off state and laser marking for durability.

2. Safety Information

WARNING: Electrical shock hazard. Always disconnect power before installation or maintenance.

  • Installation and maintenance should only be performed by qualified electrical personnel.
  • Ensure all wiring complies with local and national electrical codes.
  • Do not operate the contactor if it appears damaged.
  • Verify correct voltage and current ratings before connection.
  • Ensure proper grounding where applicable.

3. Product Overview

The GEYA GYHC Modular Contactor is a high-performance device designed for household AC applications. It offers several key advantages:

  • Super-Quiet Operation: Less than 15dB, making it ideal for residential environments.
  • Energy Saving: Up to 75% more efficient than traditional contactors.
  • Space Optimization: Up to 70% smaller than traditional contactors, allowing for more compact installations.
  • Visualization Window: Provides a clear indication of the contactor's operational status (ON/OFF).
  • Laser Marking: Durable and clear product identification.
GEYA GYHC Modular Contactor 4NO and 2NO2NC versions
Figure 3.1: GEYA GYHC Modular Contactor (4NO and 2NO2NC versions)
Video 3.2: Product overview showcasing different models and features of the GEYA GYHC series.
Space optimization and energy saving comparison for GEYA contactors
Figure 3.3: Comparison of GEYA contactor with traditional contactor, highlighting space optimization and energy savings.

4. Specifications

The GEYA GYHC Modular Contactor adheres to IEC 61095 and EN 61095 standards and is CE certified. Key technical parameters are detailed below:

Table 4.1: Main Technical Parameters
ParameterValue
Rated Voltage (Ue)220V/230V AC (Control), 400V AC (Main Circuit)
Rated Current (le)63A (AC-7a), 20A (AC-7b)
Number of Poles4
Electricity TypeAC
Frequency50/60Hz
Isolation Voltage (Ui)500V AC
Rated Impulse Withstand Voltage (Uimp)2.5kV (4kV@12/24/48VAC)
Electrical Life30,000 Times
Max Switching Frequency100 per day
Protection GradeIP20 (Breaker body), IP40 (Installed inside distribution box)
Operating Temperature-5°C to +60°C
Storage Temperature-40°C to +70°C
CertificationCE
Technical Parameters table for GEYA GYHC contactor
Figure 4.2: Detailed Technical Parameters.
Automatic Household Contactor Specification Table
Figure 4.3: Automatic Household Contactor Specification Table.
Product Model table for Manually Operated WCT Contactor-50Hz
Figure 4.4: Product Model table for Manually Operated WCT Contactor-50Hz.

5. Installation and Wiring

The GEYA GYHC Modular Contactor is designed for easy installation on a standard 35mm DIN guide rail. Follow these steps for proper installation:

5.1 Mounting

  • Mount the contactor on a 35mm DIN guide rail.
  • Ensure the contactor is installed vertically, with an allowable tilt of up to +30°.
  • If the contactor is installed inside a distribution box, a distance piece should be assembled on both sides to facilitate heat dissipation.
Installation diagram showing DIN rail mounting and dimensions
Figure 5.1: Installation diagram with dimensions for 25A and 40/63A models.

5.2 Wiring

Refer to the wiring diagrams and tables below for correct terminal connections. Use appropriate tools and ensure proper torque for secure connections.

Table 5.2: Wiring Specifications
TypeRated CurrentStripping LengthCircuitTorqueCopper Line (Hard)Copper Line (Flexible)Haze Line Terminal
GYHC16-100A (Control Loop)9mmControl Loop0.8Nm1.5-2.5mm²1.5-2.5mm²1x6mm²
16&25A (Power Loop)9mmPower Loop3.5Nm1.5x6mm²1x4mm²6x2.5mm²
40A-63A (Power Loop)14mm3.5Nm6x3.5mm²6x35mm²
GYHC5, GYHCCPZ1.4mm9mm-0.8Nm1.5-2.5mm²1.5-2.5mm²1x2.5mm²
GYHC24Power supply (N/P) Input (Y1/Y2)-1Nm0.5-10mm² 2x0.5-2x2.5mm²0.5-6mm² 2x0.5-2x2.5mm²0.5-4mm² 2x0.5-2x2.5mm²
TI24 ConnectorSpring clamp terminal-1x0.5-1.5mm²1x0.5-1.5mm²
Wiring instructions and tables for various types of connectors
Figure 5.3: Detailed wiring instructions and tables for various types of connectors.

6. Operation (Manually Operated Contactor)

The manually operated GYHC contactor features a selector switch with four positions:

  • Position O: Manual Turn Off. The contactor is manually switched off.
  • Position Auto: Automatic Operation. The contactor operates automatically based on control signals.
  • Position I: Manual Turn On. The contactor is manually switched on.
  • Position I+P: Manual Permanent Turn On. The contactor is manually switched on and remains in this state, overriding automatic control until manually changed.
Operation diagram for manually operated contactor positions
Figure 6.1: Operation diagram illustrating the four positions of the manually operated contactor.

7. Maintenance

Regular maintenance ensures the longevity and reliable operation of your GYHC Modular Contactor.

  • Cleaning: Keep the contactor free from dust and debris. Use a dry, soft cloth for cleaning.
  • Connection Check: Periodically inspect all terminal connections to ensure they are tight and secure. Loose connections can cause overheating and malfunction.
  • Visual Inspection: Check for any signs of physical damage, discoloration, or wear on the contactor body and terminals.
  • Operational Check: Verify that the manual operation switch moves freely and that the contactor engages and disengages smoothly.

For detailed maintenance procedures, refer to the official user manual PDF.

8. Troubleshooting

If you encounter issues with your GEYA GYHC Modular Contactor, consider the following common problems and solutions:

  • Contactor Not Engaging:
    • Check control circuit voltage.
    • Verify control wiring connections.
    • Ensure the manual operation switch is not in the 'O' (Manual Turn Off) position.
  • Overheating:
    • Check for loose connections.
    • Ensure the contactor is not overloaded (verify rated current).
    • Ensure adequate ventilation if installed in an enclosure.
  • Unusual Noise:
    • Inspect for foreign objects or loose parts.
    • If noise persists, consult a qualified electrician.

For more complex troubleshooting, refer to the comprehensive user manual PDF.

9. User Tips

  • Quiet Operation: Many users appreciate the super-quiet operation (less than 15dB), making this contactor an excellent choice for residential and office environments where noise reduction is important.
  • Energy Efficiency: The significant energy savings (up to 75% compared to traditional contactors) can lead to noticeable reductions in electricity bills over time.
  • Compact Design: The optimized design allows for easier installation in tight spaces, especially within existing distribution boxes.

10. Warranty and Support

GEYA products are manufactured to high-quality standards and come with a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms, conditions, and duration, please refer to the official product documentation or contact GEYA customer support.

For further assistance, detailed specifications, or troubleshooting guides, please consult the official user manual PDF available at: GEYA GYHC Modular Contactor User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.