Hantek 6074BE/6074BC/6074BD

Contents

Hantek 6074BE/6074BC/6074BD Digital Storage Oscilloscope User Manual

Model: 6074BE/6074BC/6074BD

1. General Safety Summary

Review the following safety precautions carefully before operating the device to avoid any personal injuries or damages to the device and any products connected to it. To avoid potential hazards, use the device only as specified by this user's guide.

To Avoid Fire or Personal Injury

  • Use Proper Power Cord: Use only the power cord specified for this product and certified for the country of use.
  • Connect and Disconnect Properly: Do not connect or disconnect probes or test leads while they are connected to a voltage source. Connect the probe output to the measurement device before connecting the probe to the circuit under test. Disconnect the probe input and the probe reference lead from the circuit under test before disconnecting the probe from the measurement device.
  • Observe All Terminal Ratings: To avoid fire or shock hazard, observe all ratings and markings on the product. Consult the product manual for further ratings information before making connections to the product.
  • Use Proper Probe: To avoid shock hazard, use a properly rated probe for your measurement.
  • Avoid Circuit or Wire Exposure: Do not touch exposed connections and components when power is on.
  • Do Not Operate With Suspected Failures: If suspected damage occurs with the device, have it inspected by qualified service personnel before further operations.
  • Provide Proper Ventilation: Refer to the installation instructions for proper ventilation of the device.
  • Do not operate in Wet/Damp Conditions.
  • Do not operate in an Explosive Atmosphere.
  • Keep Product Surfaces Clean and Dry.

2. Setup

2.1 System Requirements

To run the oscilloscope software, the computer configuration should meet the following:

Minimum System Requirements:

  • Operating System: Windows XP/Vista/Win7
  • Processor: Upwards of 1.00GHz processor
  • Memory: 256MB byte
  • Disk Space: 500MB disk free space
  • Screen Resolution: 800 x 600
  • Operating System: Windows XP SP3 System (Also supports Windows 10 and Windows 11)
  • Processor: 2.4GHz Processor
  • Memory: 1GB Byte Memory
  • Disk Space: 80GB Disk Space
  • Screen Resolution: 1024 x 768 or 1280 x 1024
  • DPI Setting: Normal Size (96DPI)

2.2 Accessories (What's in the Box)

The standard accessories for the Hantek 6000 series oscilloscopes include:

  • Passive Probes (x2, 1.5m, 1:1/10:1)
  • USB Cable
  • QuickGuide
  • Software Installation CD (contains user manual)
  • BNC to BNC Cable (for 6000BD models)
  • HT25 (for 6000BE models)
  • Gator Clip Lines (x3 for 6074BE, x2 for 6074BD)
  • HT307, HT19, HT18A, HT30A (for 6074BE)

The full user manual is available as a PDF: Hantek 6000 Series User Manual (PDF)

2.3 Software Installation

Caution: You must install the software before using the oscilloscope.

  1. While in Windows, insert the installation CD into the CD-ROM drive.
  2. The installation should start up automatically. Otherwise, in Windows Explorer, switch to the CD-ROM drive and run Setup.exe.
  3. The software installation will begin. Click 'Next' to continue.
  4. Choose a destination directory. Click 'Next' to continue.
  5. Check the setup information. Click 'Next' to start copying files.
  6. A status dialog will display during file copying.
  7. The system configuration will update.
  8. The installation is complete.

2.4 Driver Installation

Example: HANTEK 6000B

  1. Connect the A-Type Plug of the USB cable to your PC's USB port.
  2. Connect the other A-Type Plug of the USB cable to the device's USB port.
  3. New hardware will be found.
  4. Right-click on the new hardware and select "Manage".
  5. In Device Manager, right-click on the DSO Device and select "Update Driver Software".
  6. Select "Browse my computer for driver software".
  7. Select the correct driver path (e.g., C:\Program Files\HantekXXXX\Driver) and click "Next".
  8. If prompted by Windows Security, click "Install this driver software anyway".
  9. The Hantek USB driver will be successfully installed.
  10. After the device driver is installed correctly, the device manager will show the device without errors.
Hantek oscilloscope connected to a PC via USB
Hantek oscilloscope connected to a PC via USB.
Side view of Hantek oscilloscope showing USB and BNC connectors
Side view of Hantek oscilloscope showing USB and BNC connectors.

3. Operating Basics

The Hantek 6000 series oscilloscopes are small, lightweight, and require no external power, making them portable and ideal for various applications including production test, research, design, and automotive diagnostics.

3.1 General Features

  • Four Channels: Max Bandwidth of 70MHz.
  • Maximum Real-time Sample Rate: 1GSa/s
  • Memory Depth: 64K/CH
  • Automatic Setup (AUTOSET): For ease of use.
  • Built-in Fast Fourier Transform (FFT) function.
  • 20 Automatic Measurements.
  • Automatic Cursor Tracking Measurements.
  • Waveform Storage: Record and replay dynamic waveforms.
  • User Selectable Fast Offset Calibration.
  • Math Functions: Add, Subtract, and Multiply.
  • Selectable 20 MHz Bandwidth Limit.
  • Waveform Average.
  • Adjustable Waveform Intensity: For more effective waveform view.
  • User Interface: Available in several user-selectable languages.

3.2 User Interface Overview

After connecting the oscilloscope and installing the software, launch the application. The user interface displays waveforms and oscilloscope control settings.

  • Main Menu: All settings can be found here.
  • Toolbar: Provides quick access to common functions.
  • Trigger Information: Displays edge trigger slope, source, and level.
  • DDS Panel (HANTEK 6000BD): For waveform generator controls.
  • Horizontal Panel: Adjust Time/Div and format.
  • Vertical Panel: Turn channels ON/OFF, change Volt/Div, coupling, and probe attenuation.
  • Trigger Panel: Change trigger mode, sweep, source, and slope.
  • System Time: Displays current system time.
  • Edge Trigger Level Marker: Indicates the trigger level.
  • Main Time Base Setting: Displays the current time base.
Hantek 6074BE oscilloscope connected to a PC, showing software interface
Hantek 6074BE oscilloscope connected to a PC, showing software interface.
Software interface showing language selection menu
Software interface showing language selection menu.

3.3 Setting Up the Oscilloscope

Using "AUTOSET" to display a signal automatically:

The AUTOSET function automatically adjusts vertical scale, horizontal scale, and trigger settings for a stable waveform display. It also shows several automatic measurements.

  1. Connect a signal to the CH1 input.
  2. Click the "Acquire -> Autoset" button. The oscilloscope will adjust settings to display the signal.

Save Setup: The software saves the current setup automatically. You can also use the "Save Setup" menu to permanently save different setups.

Load Setup: The oscilloscope can recall the last setup, any saved setups, or the factory setup using the "Load Setup" menu.

Factory Setup: The oscilloscope software is set up for normal operation when shipped. To recall this setup, use the "Factory Setup" menu.

3.4 Vertical System Setup

Access the Vertical Setup window via "Setup -> Vertical" to configure vertical parameters.

  • Turn ON/Off: Enable or disable the channel.
  • Volt/DIV: Select the channel voltage/division.
  • Coupling: Choose between DC, AC, or GND. DC blocks AC components, AC blocks DC components, and GND disconnects the input.
  • Probe: Set the probe attenuation (e.g., x1, x10). This affects the vertical scale to show actual voltage levels.
  • Invert: Inverts the selected waveform by 180 degrees.

3.5 Horizontal System Setup

Access the Horizontal Setup window via "Setup -> Horizontal" to configure horizontal parameters.

  • Time/DIV: Sets the time base (scale factor) for the main or window time base.
  • Format: Set the waveform display format (Y-T for vertical voltage vs. horizontal time, X-Y for CH1 vs. CH2).

3.6 Trigger System Setup

Access the Trigger Setup window via "Setup -> Trigger" to configure trigger settings.

  • Trigger Mode: Sets the trigger mode (Edge, Pulse, Video, Alternative).
  • Trigger Sweep: Selects AUTO (acquires waveform even without trigger), NORMAL (acquires only when triggered), or SINGLE (acquires once then stops).
  • Trigger Source: Selects the channel (CH1, CH2, CH3, CH4) or external source for triggering.
  • Trigger Slope: Selects positive (+) or negative (-) edge for triggering.
  • Pulse Trigger: Detects abnormal signals based on pulse width conditions.
  • Video Trigger: Triggers on NTSC, PAL, or SECAM video signals.
  • ALT System: Allows triggering from multiple channels.
  • High Frequency Rejection: Eliminates trigger from higher-frequency components (above 20MHz).

3.7 Waveform Generator (HANTEK 6000BD only)

The Hantek 6000BD models include an Arbitrary Waveform Generator with one channel, 8-bit output, and synchronized signal outputs. You can edit arbitrary waveforms or choose from predefined waveforms like Sine, Square, AM/FM, Ramp, Trapezia, Gause, Arb, Exponent, and White.

To access, select the DDS control panel in the sidebar.

3.8 Measure Signal

The oscilloscope provides 20 parametric auto measurements (12 voltage and 8 time measurements).

  • Cursor Menu: Use cursors to make time and amplitude measurements. Select the source channel (CH1, CH2, CH3, CH4, or MATH) and the cursor type (Cross, Trace, Vertical, Horizontal).
  • Measure Menu: Access via "Measure" in the main menu. Provides various measurements like Vpp, Vmax, Vmin, Frequency, Period, Rise Time, Fall Time, Duty Cycle, etc.

3.9 Display System

Configure how waveforms are displayed.

  • Display Type: Choose between Vectors (lines connecting sample points) or Dots (individual sample points).
  • Grid: Enable or disable the display grid.
  • Intensity: Adjust the intensity of the grid and waveform colors.

3.10 Zoom In/Out and Drag Waveforms

After stopping waveform acquisition, you can zoom in/out and drag waveforms to analyze specific details. Use the "Acquire -> Zoom In/Out" menu or the mouse buttons on the display screen.

3.11 Acquisition Modes

The oscilloscope offers three acquisition modes:

  • Normal: Samples the signal at evenly spaced intervals.
  • Average: Acquires and averages multiple waveforms to reduce random noise.
  • Peak Detect: Finds the maximum and minimum values in each sampling interval.

3.12 Save/Load and Print

  • Save/Load: Save current setups, waveforms, or screen images. Load previously saved data.
  • Print: Print the current waveform or preview it before printing.

4. Maintenance

4.1 General Care

  • Do not store or leave the oscilloscope where the device will be exposed to direct sunlight for long periods.
  • To avoid damages to the device or probes, do not expose them to sprays, liquids or solvents.
  • To avoid damages to the surface of the device or probes, do not use any abrasive or chemical cleaning agents.

4.2 Cleaning

Inspect the device and probes as often as operating conditions require. Make sure the device is disconnected from all power sources before cleaning.

To clean the exterior surface, perform the following steps:

  1. Remove loose dust on the outside of the oscilloscope and probes with a lint-free cloth. Use care to avoid scratching the clear glass display filter.
  2. Use a soft cloth dampened with water to clean the device.

5. Troubleshooting

5.1 General Check

After receiving your oscilloscope, perform these checks:

  • Check the shipping container for damage: Keep the damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness and the instrument has been checked mechanically and electrically.
  • Check the accessories: Verify that all accessories listed in the "Accessories" section are present and undamaged. If anything is missing or damaged, contact your supplier.
  • Check the instrument: In case of mechanical damage, defect, or improper operation, notify your supplier.

5.2 Function Check

Perform this functional check to verify that your oscilloscope is operating correctly.

  1. Connect the oscilloscope: Connect the USB cable from your PC to the oscilloscope.
  2. Input a signal to a channel: Set the probe attenuation to 10X and connect the probe to CH1. Attach the probe tip to the Probe Compensator and the reference lead to the ground connector.
  3. Click the "AUTOSET" button. A square wave (approximately 1 kHz, 2V peak-to-peak) should be displayed.
  4. Inspect CH2 with the same method.

5.3 Probe Compensation

This function matches the characteristics of the probe and the channel input. Perform this whenever attaching a probe to any input channel for the first time.

  1. From the "Probe" menu, select attenuation to 1:10. Set the switch to "X10" on the probe.
  2. Connect the probe to CH1 of the oscilloscope.
  3. Attach the probe tip to the Probe Compensator and the reference lead to the ground connector. Select CH1, and then press the "AUTOSET" button.
  4. Check the shape of the displayed waveform.
  5. If necessary, use a non-metallic tool to adjust the trimmer capacitor of the probe for the flattest square wave.
Correctly Compensated Waveform
Example of a correctly compensated waveform.

5.4 Self Calibration

The self-calibration routine optimizes the oscilloscope signal path for maximum measurement accuracy. Run this routine if the ambient temperature changes by 5°C or more. For accurate calibration, power on the oscilloscope and wait twenty minutes for it to warm up. Disconnect any probes or cables from the input connectors before running the routine. Access "Utility -> Calibration" and follow the on-screen directions.

5.5 User Tips

  • The device is compatible with Windows 7, Windows 8, Windows 10, and Windows 11.
  • Ensure all software and drivers are installed correctly before first use.
  • The device offers a user interface in several user-selectable languages, including English.
  • For automotive diagnostics, the Hantek 6074BE model is specifically equipped with over 80 types of automotive measurement functions.

6. Specifications

The Hantek 6000 series digital storage oscilloscopes offer robust performance for various electrical measurement tasks.

Table of Hantek 6000 Series models and their specifications
Hantek 6000 Series Model Selection Table.
General Specifications
FeatureSpecification
ModelHantek6074BE/6074BC/6074BD
Bandwidth70MHz
Channel4 CH
Real-time Sampling Rate1GSa/s
Memory Depth64K
Time Base Precision±50ppm
Time Base Range2ns/div-1000s/div (1-2-4 sequences)
Input Impedance1MΩ 25pF
Input Sensitivity2mV/div-10V/div
Vertical Resolution8Bit
Vertical Displacement Range2mV ~ 10V/div @ x1 probe; 20mV ~ 100V/div @ x10 probe; 200mV ~ 1000V/div @ x100 probe; 2V ~ 10000V/div @ x1000 probe
DC Gain Accuracy±3%
Bandwidth Limit20MHz
Trigger ModeEdge, Pulse, Video, Alternative
Trigger SourceCH1, CH2, CH3, CH4
Waveform Signal Process+,-,x,÷,FFT, Invert
Cursors MeasurementCross, Trace, Horizontal, Vertical
Auto MeasurementVpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle
Volume175mm * 105mm * 25mm
Weight0.9KG

Arbitrary Waveform Generator Mode (HANTEK 6000BD)

FeatureSpecification
Waveform FrequencyDC~25MHz
DAC2K~200MHz adjustable
Frequency Resolution0.10%
Channel1CH waveform output
Waveform Depth2KSa
Vertical Resolution12 bit
Frequency Stability<30ppm
Wave Amplitude±3.5V Max.
Output Impedance50 Ω
Output Current50mA, Ipeak=50mA
System BW25M
Harmonic Distortion-50dBc(1KHz), -40dBc(10KHz)

7. Warranty and Support

For detailed warranty information and technical support, please refer to the official Hantek website or contact your local distributor. The latest software updates and additional resources may be available online.

Official Hantek Website: http://www.hantek.com