TECNR FX3U-56MR/MT

Contents

TECNR FX3U-56MR/MT PLC Industrial Control Board User Manual

Model: FX3U-56MR/MT | Brand: TECNR

1. Introduction

This manual provides essential information for the safe and efficient operation of your TECNR FX3U-56MR/MT Programmable Logic Controller (PLC) industrial control board. This PLC is designed for various industrial automation applications, offering robust control capabilities with multiple inputs, outputs, and communication options.

TECNR FX3U-56MR/MT PLC industrial control board with clear protective casing
Figure 1: TECNR FX3U-56MR/MT PLC Industrial Control Board

2. Key Features

  • Supports human-machine interface (HMI) linking, compatible with FX3U applications.
  • Equipped with an industrial-grade 32-bit MCU for strong anti-interference and high-speed operation.
  • Supports ladder programming, download, and monitoring.
  • Compatible with Mitsubishi GX-Developer and GX-Works2 software.
  • High-speed inputs (X0-X5) for up to 3 AB encoders (default 12K, optional 100K).
  • 6 analog inputs (3 channels 0-10V, 3 channels 0-20mA).
  • 2 analog outputs (0-10V).
  • Power-down hold functionality, freely settable.
  • Optional CAN communication extension.
  • Available with Relay (MR) or Transistor (MT) output types.
  • Integrated Real-Time Clock (RTC) and RS485 Modbus RTU communication.

3. Specifications

The following table details the specifications for the FX3U-56MR and FX3U-56MT models.

Feature FX3U-56MR FX3U-56MT
Output Type Relay Transistor
Download Speed 38.4kb 38.4kb
Memory Capacity 8000 steps 8000 steps
Input Voltage 24V 220V 24V 220V
Output Current 5A 1A
Digital Input Points 32 32
Digital Output Points 24 24
Analog Input AD0~AD2 0-10V, AD3~AD5 0-20MA AD0~AD2 0-10V, AD3~AD5 0-20MA
Analog Output 2DA 0-10V 2DA 0-10V
RS485/RTC YES YES
MODBUS YES YES
CAN YES YES
Software GX Developer OR GX Works2 GX Developer OR GX Works2
Comparison of MR Relay and MT Transistor output types on PLC boards
Figure 2: Output Type Comparison (MR Relay vs. MT Transistor)
TECNR FX3U-56MR-RTC-485-CAN PLC board layout
Figure 3: FX3U-56MR-RTC-485-CAN Board Layout
TECNR FX3U-56MT-RTC-485-CAN PLC board layout
Figure 4: FX3U-56MT-RTC-485-CAN Board Layout

4. Setup and Installation

4.1 Power Supply

The industrial control board requires a DC 24V power supply. Ensure that you connect only DC 24V to the power input terminals. WARNING: Do not connect AC power or 220V voltage directly to the PLC, as this will damage the device.

24V 2A 50W Switch Power Supply
Figure 5: Example of a compatible 24V 2A 50W Switch Power Supply

4.2 Programming Cable Connection

To program the PLC, you will need a serial programming cable to connect it to your PC. The PLC uses RS232 communication by default for programming. If your PC does not have an RS232 port, a USB to RS232 converter cable will be necessary.

USB to RS232 Serial Cable
Figure 6: Example of a USB to RS232 Serial Cable
Male to Female DB9 Serial Cable for PLC programming
Figure 7: Example of a Male to Female DB9 Serial Cable

4.3 Input/Output Wiring

Connect your sensors, switches, and other input devices to the digital input points (X0-X31). Connect your actuators, relays, and other output devices to the digital output points (Y0-Y23). Refer to the specific wiring diagrams for your application. For analog signals, use the dedicated analog input (AD0-AD5) and output (DA0-DA1) terminals.

5. Operation

5.1 Programming Software

The TECNR FX3U PLC is programmable using Mitsubishi GX Developer or GX Works2 software. Install the appropriate software on your PC.

5.2 Ladder Logic Programming

  1. Launch GX Developer or GX Works2.
  2. Create a new project and select the FX3U series PLC model.
  3. Develop your ladder logic program according to your control requirements.
  4. Connect the PLC to your PC using the programming cable.
  5. Download the program to the PLC.
  6. Utilize the monitoring function within the software to observe the PLC's operation and debug your program.

5.3 High-Speed Inputs

The PLC features high-speed inputs (X0-X5) capable of connecting up to three AB encoders. The default speed is 12K, with an optional configuration for 100K. Consult the software documentation for configuring high-speed input parameters.

5.4 Analog I/O

The PLC includes 6 analog inputs (3 channels for 0-10V and 3 channels for 0-20mA) and 2 analog outputs (0-10V). Ensure proper scaling and configuration within your ladder logic program to correctly interpret and generate analog signals.

5.5 Communication (RS485/Modbus RTU)

The FX3U-56MR/MT models include RS485 communication, supporting the Modbus RTU protocol. This allows for integration with other Modbus-compatible devices. Refer to the programming software and Modbus protocol documentation for detailed setup and communication instructions.

5.6 Real-Time Clock (RTC)

The FX3U-56MR/MT models include Real-Time Clock (RTC) functionality, allowing for time-based control and scheduling within your PLC program. The RTC can be accessed and configured via the programming software.

6. Maintenance

  • Keep the PLC clean and free from dust and moisture.
  • Ensure proper ventilation around the unit to prevent overheating.
  • Regularly check all wiring connections for tightness and signs of wear.
  • Periodically back up your PLC programs to prevent data loss.
  • Avoid exposing the PLC to extreme temperatures or corrosive environments.

7. Troubleshooting

  • PLC not powering on:
    • Verify that the DC 24V power supply is correctly connected and providing the correct voltage.
    • Check the power indicator LED on the PLC.
  • Program not downloading:
    • Ensure the programming cable is securely connected to both the PC and the PLC.
    • Confirm that the correct COM port is selected in the programming software.
    • Check for any communication errors reported by the software.
  • Inputs/Outputs not responding:
    • Verify the wiring of the input/output devices.
    • Check the status indicators for the specific input/output points on the PLC.
    • Review your ladder logic program for correct addressing and logic.
  • Communication issues (RS485/Modbus):
    • Ensure the RS485 wiring is correct (A to A, B to B).
    • Verify Modbus parameters (baud rate, parity, data bits, stop bits) match between the PLC and the communicating device.
    • Check for proper termination resistors if applicable.

8. User Tips

  • RS485 Communication: The FX3U-56MR/MT models include RS485. When setting up, ensure your wiring is correct and communication parameters (baud rate, data bits, parity, stop bits) match between the PLC and any connected devices.
  • Real-Time Clock (RTC): Utilize the built-in RTC for time-sensitive control applications. This feature is standard on the FX3U-56MR/MT models.
  • Programming Software: While both GX Developer and GX Works2 are compatible, GX Works2 is generally newer and offers more advanced features and a more modern interface. Consider using GX Works2 for new projects if available.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your vendor or the manufacturer directly. Keep your purchase records handy when seeking support.