GEYA GRT8-M/K

Contents

GEYA Multifunction Timer Relay GRT8-M/K Series Instruction Manual

Models: GRT8-M1, GRT8-M2, GRT8-K1, GRT8-K2

1. Introduction

The GEYA Multifunction Timer Relay (GRT8-M/K series) is a versatile device designed for various electrical control applications, including lights, heating systems, motors, pumps, and fans. This manual provides essential information for the safe and effective installation, operation, and maintenance of your timer relay.

Four GEYA timer relay models: GRT8-M1, GRT8-M2, GRT8-K1, GRT8-K2
Figure 1: GEYA Multifunction Timer Relay GRT8-M and GRT8-K Series

2. Safety Information

WARNING: To prevent electric shock or damage to the device, please read and understand all instructions before installation and operation. Installation and maintenance should only be performed by qualified electricians in compliance with appropriate safety standards.

  • Ensure power is disconnected before any installation, wiring, or maintenance.
  • Verify correct voltage and current ratings before connecting the device.
  • Do not expose the device to moisture or extreme temperatures.
  • All electrical connections must comply with local and national electrical codes.

3. Product Overview

The GRT8-M/K series offers both adjustable (potentiometer) and digital setting timer relays with multiple functions and wide voltage compatibility.

3.1 GRT8-M Series (Adjustable)

  • Functions: 10 time functions (5 controlled by supply voltage, 4 by control input, 1 latching relay function).
  • Time Ranges: 10 ranges from 0.1 seconds to 10 days, set by potentiometer.
  • Voltage Range: AC230V or AC/DC12-240V.
  • Output: 1SPDT (16A) or 2SPDT (16A).

3.2 GRT8-K Series (Digital Setting)

  • Functions: 4 functional modes (On Delay, Interval, Off Delay, Single Shot).
  • Time Ranges: 8 ranges from 0.1 seconds to 99 hours, set by digital dialing.
  • Voltage Range: AC230V or AC/DC12-240V.
  • Output: 1SPDT (16A) or 2SPDT (8A).
Digital Setting Time Relay GRT8-K1 and GRT8-K2 showing delay times and functions
Figure 2: GRT8-K Digital Setting Timer Relay

4. Specifications

Parameter GRT8-M1 / GRT8-M2 GRT8-K1 / GRT8-K2
Function A, B, C, D, E, F, G, H, I, J A, B, E, F
Supply Terminals A1-A2
Voltage Range AC/DC 12-240V (50-60Hz) or AC 230V (50-60Hz)
Power Input AC max.6VA/1.3W (M1), AC max.6VA/1.9W (M2) AC max.6VA/1.3W (K1), AC max.6VA/1.9W (K2)
Supply Indication Green LED
Time Ranges 0.1s-10days, ON, OFF 0.1s-9.9s, 0.1m-9.9m, 0.1h-9.9h, 1s-99s, 1m-99m, 1h-99h, ON, OFF
Time Setting Potentiometer Digital Dialing
Output 1xSPDT (M1), 2xSPDT (M2) 1xSPDT (K1), 2xSPDT (K2)
Current Rating 1x16A (AC1) 1x16A (AC1) (K1), 2x8A (AC1) (K2)
Output Indication Red LED
Mounting DIN rail EN/IEC 60715
Protection Degree IP40 (front panel), IP20 (terminals)
Dimensions (mm) 90 x 18 x 64
Weight (approx.) 62-63g (1SPDT), 81-82g (2SPDT) 62-63g (1SPDT), 81-82g (2SPDT)
Certification CE, CB, ROHS
Technical parameters table for GRT8-M1 and GRT8-M2
Figure 3: Technical Parameters for GRT8-M Series
Technical parameters table for GRT8-K1 and GRT8-K2
Figure 4: Technical Parameters for GRT8-K Series

5. Setup

5.1 Mounting

The GEYA Timer Relay is designed for DIN rail mounting (EN/IEC 60715). Ensure the mounting location is free from excessive vibration, moisture, and extreme temperatures.

5.2 Wiring

Refer to the wiring diagrams below for proper connection. Always ensure power is off before making any connections.

5.2.1 Terminal Designations:

  • A1, A2: Supply Terminals (Un)
  • S: Trigger Terminal (for control input functions)
  • 15, 16, 18: SPDT Output Contacts (15-16 Normally Closed, 15-18 Normally Open)
  • 25, 26, 28: Second SPDT Output Contacts (for 2SPDT models)
Technical parameter diagram for GRT8-M1 and GRT8-M2 showing terminals and controls
Figure 5: GRT8-M Series Terminal Layout and Controls
GRT8-K1 diagram showing time range, function, and time settings with wiring diagram
Figure 6: GRT8-K Series Terminal Layout and Controls with Wiring Diagram
Wiring diagram for GRT8-M1 and GRT8-M2
Figure 7: GRT8-M Series Wiring Diagram

6. Operating Instructions

The timer relay features a green LED (Un) for supply indication and a red LED (R) for output indication. The output contacts change state after the set time delay is complete.

6.1 Time Setting (GRT8-M Series)

The GRT8-M series uses two rotary knobs for time setting:

  1. Knob 1 (Time Range): Selects the delay gear (e.g., 's' for seconds, 'm' for minutes, 'h' for hours, 'd' for days). Also includes 'ON' (relay always closed) and 'OFF' (relay always open) settings.
  2. Knob 2 (Fine Adjustment): Adjusts the delay time from 10% to 100% of the selected time range.

Formula: Delay time = Knob 1 setting × Knob 2 percentage.

Example: To set a 5-second delay:

  • Set Knob 1 to '10s'.
  • Set Knob 2 to '50%'.
  • Calculated Delay Time = 10s × 50% = 5s.

6.2 Time Setting (GRT8-K Series)

The GRT8-K series uses digital dialing for precise time setting. Refer to the product overview for available time ranges (e.g., 0.1s-9.9s, 1s-99s, 0.1h-9.9h, etc.).

6.3 Function Modes (GRT8-M Series)

The GRT8-M series offers 10 distinct functions. The video below demonstrates several of these functions:

Video 1: Demonstration of GRT8-M1 Timer Relay Functions (On Delay, Interval, Repeat Cycle, Off Delay, Single Shot, Latching Relay, Pulse Generator).

Detailed descriptions of each function are provided in the diagram below:

Functions Diagram for GRT8-M, illustrating A (On Delay), B (Interval), C (Repeat Cycle Starting Off), D (Repeat Cycle Starting On), E (Off Delay S Break), F (Single Shot), G (Single Shot Trailing Edge), H (On/Off Delay), I (Latching Relay), J (Pulse Generator), and Time Range settings.
Figure 8: GRT8-M Series Functions Diagram
Diagram showing 10 Delay Functions for GRT8-M2, categorizing them by supply voltage control, control input, and latching relay. Defines Un, R, S, t.
Figure 9: GRT8-M Series 10 Delay Functions Overview

6.4 Function Modes (GRT8-K Series)

The GRT8-K series offers 4 distinct functions:

Functions Diagram for GRT8-K, illustrating A (On Delay), B (Interval), E (Off Delay), F (Single Shot), and Time Range settings.
Figure 10: GRT8-K Series Functions Diagram
  • A: On Delay (Power On): Relay contacts change state after a set time delay once input voltage is applied.
  • B: Interval (Power On): Relay contacts change state immediately when input voltage is applied, and return to shelf state after a set time delay.
  • E: Off Delay (S Break): Relay contacts change state when trigger switch S is closed. When S is opened, a delay begins before contacts return to shelf state.
  • F: Single Shot: Relay contacts transfer and a preset time begins upon application of trigger signal S.

7. Maintenance

  • Regularly inspect wiring connections for tightness and signs of wear.
  • Keep the device clean and free from dust and debris. Use a dry, soft cloth for cleaning.
  • Ensure proper ventilation around the device to prevent overheating.

8. Troubleshooting

  • Device not powering on: Check the supply voltage at terminals A1-A2. Ensure the circuit breaker is on.
  • Output not switching: Verify the function mode and time settings are correct. Check the trigger input (S terminal) if using control input functions.
  • Incorrect timing: Re-check the time range and fine adjustment settings. For GRT8-K, ensure digital dials are set accurately.
  • Output voltage issues: The output voltage will be the same as the voltage supplied to the load connected to the output contacts (15, 16, 18, etc.). It is not a fixed AC 230V output from the relay itself.

9. User Tips

  • Many users find GEYA timer relays to be reliable and perform exactly as described.
  • For precise timing, especially with the GRT8-M series, carefully adjust both the time range and percentage knobs.
  • The digital setting on the GRT8-K series offers greater accuracy and ease of setting compared to analog potentiometers.
  • Always double-check your wiring against the provided diagrams to avoid misconfiguration.

10. Warranty and Support

GEYA products are certified to required industry standards, including CE, CB, and ROHS, ensuring quality and safety.

For further technical assistance or detailed documentation, please refer to the official user manual PDF available from the seller or GEYA's website. The PDF manual provides comprehensive information on installation, operation, and troubleshooting.

Note: The provided PDF manual can be accessed via the seller's product page or GEYA's official website.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.