1. Introduction

The KONLEN Wireless Keypad RFID is a versatile accessory designed to enhance your home security system. It allows for convenient arming and disarming of your alarm system using either a secure passcode or an RFID tag. This keypad communicates with your alarm hub via a reliable 433MHz RF frequency, ensuring effective operation within an 80-meter range (without obstacles). Its internal lithium-ion rechargeable battery provides extended power, offering up to 3 months of operation on a single charge.

KONLEN Wireless Keypad RFID front view

Front view of the KONLEN Wireless Keypad RFID.

2. Key Features

  • Wireless Operation: Connects to the alarm hub wirelessly via 433MHz RF frequency.
  • Multiple Arm/Disarm Methods: Supports passcode entry and RFID tag scanning for flexible security management.
  • Password Safe Operation: Ensures secure access to your alarm system.
  • One-Key Arm/Disarm: Simplifies daily security routines.
  • Long Battery Life: Internal rechargeable lithium-ion battery provides up to 3 months of use.
  • Doorbell Function: Integrated doorbell feature for visitor alerts.
Keypad features: Password safe operation, One key Arm/Disarm. Shows remote, RFID, panel, wireless keypad, app arm/disarm.

Overview of the keypad's features and various arm/disarm methods.

3. Compatibility

The KONLEN Wireless Keypad RFID is compatible with specific KONLEN alarm panels. Please ensure your alarm panel is one of the models shown in the image below for proper functionality. Other alarm panel types not pictured may not be compatible.

Compatibility with various KONLEN alarm panels.

Compatible KONLEN alarm panels.

4. Specifications

AttributeValue
Brand NameKONLEN
OriginMainland China
CertificationNONE
Smart Home PlatformOther
Wireless Keypad Featurewith RFID function
Arm/Disarm MethodWith password
Wireless Frequency433mhz
Installation PlaceHome Entrance or Gate exit
Power SupplyMicro USB+5VDC/1000mA
Backup Battery3.7V, 500mAh Lithium-ion
Battery Consumption<15uA@sleep and <15mA@ready
RFID Chip4100/4200
RFID Frequency125KHz
Operation Temperature-10~55℃

Dimensions

Product dimensions for the white keypad: 137.6mm height, 87.7mm width, 17.1mm thickness.

Dimensions of the keypad: 137.6mm (Height) x 87.7mm (Width) x 17.1mm (Thickness).

5. Setup

5.1. Keypad Components

Diagram of keypad components including RFID tag reader zone, indicators, arming/disarming buttons, doorbell button, clear/return, check/set/continue, tamper switch, battery on/off switch, power/charging port, bracket, and back cover.

Detailed diagram of the keypad's front and back components.

  1. RFID tag reader zone
  2. Power/Ready indicator
  3. Away/Home arming indicator
  4. Disarming indicator
  5. Setting indicator
  6. Away arming button
  7. Disarming button
  8. Home arming button
  9. Doorbell button
  10. Clear/Return button
  11. Check/Set/Continue button
  12. Tamper switch
  13. Battery on/off switch
  14. Power/Charging port
  15. Bracket
  16. Back cover

5.2. Initial Power On

Locate the battery on/off switch (13) on the back of the keypad. Slide the switch to the 'ON' position to power on the device. The indicators on the front will light up briefly.

5.3. Pairing with Alarm Hub

To integrate the wireless keypad with your KONLEN alarm system, follow these steps:

  1. On your alarm hub, navigate to the 'Parts' or 'Accessories' menu.
  2. Select 'Remote' or 'Keypad' option.
  3. Choose to 'Add' a new device. The hub will enter a pairing mode, often indicated by a countdown or a specific sound.
  4. On the wireless keypad, press any arming or disarming button (6, 7, or 8). The keypad will send a signal to the hub.
  5. The alarm hub should confirm successful pairing.

Refer to the video below for a visual guide on pairing the keypad with the alarm host and demonstrating arm/disarm functions.

Video: Demonstrating keypad pairing and arm/disarm functions with the alarm host and mobile app.

5.4. Doorbell Pairing

The doorbell identification number is distinct from the arming/disarming ID. You must pair the doorbell code with your hub separately:

  1. Set your alarm hub into pairing/sniffer mode.
  2. Press the doorbell button (9) on the keypad to send the doorbell transmission signal to the hub.
  3. The hub will provide a successful indication.

The doorbell function can now be used.

Doorbell pairing instructions: Set hub to pairing mode, press doorbell button on keypad, hub indicates success.

Doorbell pairing instructions.

Video: Demonstrating doorbell pairing process.

6. Operation

6.1. Arming and Disarming with Passcode

To arm or disarm your system using a user passcode:

  • To Away Arm: Enter your user passcode, then press the Away Arming button (6).
  • To Disarm: Enter your user passcode, then press the Disarming button (7).
  • To Home Arm: Enter your user passcode, then press the Home Arming button (8).

6.2. Arming and Disarming with RFID Tag

To arm or disarm your system using an RFID tag:

  • To Away Arm: Press the Away Arming button (6), then tap your RFID tag on the RFID tag reader zone (1).
  • To Disarm: Press the Disarming button (7), then tap your RFID tag on the RFID tag reader zone (1).
  • To Home Arm: Press the Home Arming button (8), then tap your RFID tag on the RFID tag reader zone (1).
Instructions for arming and disarming using user passcode and RFID tag.

Instructions for using user passcode and RFID tag.

7. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the keypad. Avoid abrasive cleaners or solvents.
  • Battery Charging: Recharge the keypad using the Micro USB port (14) when the battery low indicator is active.
  • Placement: Install the keypad in a location that is easily accessible but protected from extreme temperatures and direct moisture.

8. Troubleshooting

  • Keypad not responding: Ensure the battery on/off switch is in the 'ON' position and the battery is charged.
  • Keypad beeps regularly: This might indicate a low battery. Check the battery status and recharge if necessary.
  • RFID tag not working: Ensure you are tapping the tag correctly on the RFID tag reader zone (1) after pressing the desired arm/disarm button. If issues persist, the tag might need to be re-added to the system.
  • Cannot change passcode: Passcode changes are typically managed through the main alarm hub settings. Consult your alarm hub's manual for detailed instructions on changing user passcodes.

9. User Tips

  • Battery Life: The keypad's battery can last for many months with domestic use. The alarm system will typically notify you when the batteries are low.
  • RFID Tag Sensitivity: Some users have noted that the RFID reader might require a firm and direct tap of the tag after pressing the arm/disarm button.
  • Setup Complexity: While initial setup can be a bit complex, following the instructions carefully and watching the provided videos can help.

10. Warranty and Support

For warranty information and technical support, please refer to the documentation provided with your main KONLEN alarm system or contact KONLEN customer service directly. Keep your purchase receipt for warranty claims.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.