TKXEC ZK-4KX

Contents

ZK-4KX DC DC Buck Boost Converter User Manual

Model: ZK-4KX | Brand: TKXEC

1. Introduction

The ZK-4KX DC DC Buck Boost Converter is a versatile power module designed for precise voltage and current regulation. It features a clear LCD display for monitoring various parameters, CNC adjustment for accurate control, and multiple protection mechanisms to ensure safe operation. This module can both step up and step down voltage, making it suitable for a wide range of applications, including use as an adjustable laboratory power supply.

2. Key Features

  • LCD display shows input/output voltage, output current, output power, output capacity, and output time.
  • CNC adjustment for precise and fast voltage and current control.
  • Adjustable output voltage from 0.5V to 30V.
  • Adjustable current limit from 0A to 4A.
  • Input anti-reverse connection protection.
  • Output anti-reverse irrigation protection (no additional diode needed for battery charging).
  • Configurable default ON/OFF state upon power-up.
  • Multiple software protection mechanisms with adjustable thresholds.
  • Low output ripple with PI filter.
  • Thickened radiator fins for improved heat dissipation.

3. Product Specifications

ParameterValue
Input Voltage5.0V - 30V DC
Output Voltage0.5V - 30V DC
Output Current3A (stable long-term), 4A (with enhanced heat dissipation)
Output Power35W (natural heat dissipation), 50W (enhanced heat dissipation)
Voltage Display Resolution0.01V
Current Display Resolution0.001A
Conversion EfficiencyApproximately 88%
Soft StartYes (may fail with high power/load at start)
Operating Frequency180KHz
Dimensions (L*W*H)79mm * 43mm * 26mm
Weight92g (including package)

4. Component Overview

Familiarize yourself with the main components and controls of the ZK-4KX module:

Front panel of ZK-4KX module with SW button, U/I button, Rotary encoder, Constant current indicator (CC), and Output indicator (ON) labeled.
Figure 1: Front Panel Controls and Indicators
  • SW Button: Used for switching display parameters and toggling settings.
  • U/I Button: Used for entering voltage/current setting interfaces and parameter settings.
  • Rotary Encoder: Used for adjusting values (left/right rotation) and selecting digits (short press). Long press to toggle output ON/OFF or confirm settings.
  • CC Indicator: Illuminates when the module is operating in constant current mode.
  • ON Indicator: Illuminates when the output is active.
Top view of the ZK-4KX module showing internal components including a high efficiency ferrosilicon aluminum inductor, a thicker fin heatsink, and a π filter.
Figure 2: Internal Components and Heat Management
Rear view of the ZK-4KX module showing screw terminals labeled IN+, IN- for input and OUT+, OUT- for output, with voltage ranges 5.0-30V and 0.5-30V respectively.
Figure 3: Input and Output Terminals

5. Setup and Connection

Before connecting, ensure your power source and load are within the module's specified ranges.

  1. Power Source Connection: Connect your DC power source (5.0V-30V) to the IN+ and IN- terminals. Ensure correct polarity.
  2. Load Connection: Connect your load to the OUT+ and OUT- terminals.
  3. Initial Power-Up: Apply power to the module. The LCD display should illuminate.

Important: Do not short-circuit the input (IN) and output (OUT) terminals, as this will disable the constant current function.

6. Operating Instructions

The ZK-4KX module offers various display modes and setting options through its buttons and rotary encoder.

6.1. Display Parameter Switching

In the normal operating interface (Figure 4):

  • Short press SW: Toggles the display content below the main voltage/current reading between Current (A), Power (W), Capacity (Ah), and Time (h).
  • Long press SW: Toggles the uplink display (top line) between Input Voltage (IN) and Output Voltage (OUT).
Normal operating interface of the ZK-4KX module LCD, showing output voltage, output current, output power, output capacity, and output time.
Figure 4: Normal Interface Display

6.2. Setting Output Voltage and Constant Current

To adjust the output voltage or set the constant current limit (Figure 5):

  1. Enter Setting Interface: Short press the U/I button from the normal interface. A digit of the output voltage value will flash.
  2. Adjust Output Voltage: Rotate the encoder left/right to change the value. Short press the encoder to select which digit to adjust.
  3. Switch to Current Setting: After setting the voltage, short press the U/I button again to switch to the constant current value setting. A digit of the constant current value will flash.
  4. Adjust Constant Current: Rotate the encoder left/right to change the value. Short press the encoder to select which digit to adjust.
  5. Exit Setting: Short press the U/I button to exit and return to the normal interface. The module will also automatically return after 10 seconds of inactivity.
Interface for setting output voltage and limiting current on the ZK-4KX module, showing 'OUT 12.00V' and 'SET 0.000A' with arrows indicating adjustment points.
Figure 5: Setting Voltage and Current Interface

6.3. Setting Default Power-On State

To configure whether the module output is ON or OFF by default when powered on:

  1. Enter Parameter Setting: Long press the U/I button from the normal interface. The display will show "OPEN OFF" (output OFF by default) or "OPEN ON" (output ON by default).
  2. Toggle State: Long press the rotary encoder to switch between these two states.
  3. Exit Setting: Long press the U/I button to return to the normal interface.

6.4. Key Function Summary

The following table summarizes the functions of the buttons and rotary encoder across different interfaces (Figure 6):

Table summarizing key functions of SW button, U/I button, and Rotary encoder across Normal Interface, Regulating Voltage and Constant Current Interface, and Set Parameters Interface.
Figure 6: Key Function Table

7. Protection Mechanisms

The ZK-4KX module includes several software-based protection features to safeguard itself and connected devices. When a protection threshold is exceeded, the output will automatically shut off.

  • Input Anti-Reverse Connection: Prevents damage if input polarity is reversed.
  • Output Anti-Reverse Irrigation: Prevents current flow back into the module from the output.
  • Input Undervoltage Protection (LUP): Adjustable from 4.8V to 30V (default 4.8V). Output disconnects if input voltage drops below this threshold.
  • Output Overvoltage Protection (OUP): Adjustable from 0.5V to 31V (default 31V).
  • Output Overcurrent Protection (OCP): Adjustable from 0A to 4.1A (default 4.1A).
  • Overpower Protection (OPP): Adjustable from 0W to 50W (default 50W).
  • Overtemperature Protection (OTP): Adjustable from 80°C to 110°C (default 110°C).
  • Timeout Protection (OHP): Adjustable from 0 to 100 hours (default OFF).
  • Super Capacity Protection (OAP): Adjustable from 0 to 60Ah (default OFF).

7.1. Setting Protection Parameters

To set or adjust protection thresholds (Figure 7):

  1. Enter Parameter Setting: Long press the U/I button from the normal interface.
  2. Navigate to Protection: Short press the SW button repeatedly until the desired protection parameter (e.g., LUP, OUP, OCP) appears.
  3. Adjust Threshold: Short press the rotary encoder to select the digit to adjust. Rotate the encoder left/right to change the value.
  4. Enable/Disable (for OHP, OAP): Long press the rotary encoder to toggle the protection ON or OFF (only applicable for Timeout and Super Capacity Protection). Other protections are ON by default.
  5. Exit Setting: Long press the U/I button to return to the normal interface.
Interface for setting various protection parameters on the ZK-4KX module, including LUP (Undervoltage), OUP (Overvoltage), OCP (Overcurrent), OPP (Overpower), OAP (Overcapacity), OHP (Timeout), and OTP (Overtemperature).
Figure 7: Setting Protection Parameters Interface
Protection Interface screens on the ZK-4KX module, showing different protection types like Under Voltage Protection (LUP), Over Voltage Protection (OUP), Over Current Protection (OCP), Over Power Protection (OPP), Over Capacity Protection (OAP), Timeout Protection (OHP), and Over Temperature Protection (OTP).
Figure 8: Protection Interface Overview

8. Calibration

To ensure accuracy, you can calibrate the voltage and current readings of the module.

  1. Enter Parameter Setting: Long press the U/I button from the normal interface.
  2. Navigate to Calibration: Short press the SW button until a parameter interface with "CAL" appears.
    • CAL+IN+V: Calibrate input voltage.
    • CAL+OUT+V: Calibrate output voltage.
    • CAL+OUT+A: Calibrate output current.
  3. Adjust Parameters: Rotate the encoder left/right to adjust the value.
  4. Confirm Calibration: After adjustment, long press the rotary encoder to confirm. The parameter value will stop flashing.
  5. Exit Setting: Long press the U/I button to return to the normal interface.

Note: For accurate calibration, ensure the calibration voltage is above 12V and the calibration current is above 1A.

9. Important Cautions

  • Short Circuit: Avoid short-circuiting the input (IN) and output (OUT) terminals. This will cause the constant current function to fail.
  • Power Source: Ensure your power supply's capacity exceeds the required power of your output load.
  • Full Load Operation: For full load output, the input voltage should ideally be above 8V. When the input voltage is 5V, the output power is limited to approximately 15W.
  • Maximum Current: The module's maximum current is 4A. This is subject to the maximum output power. For example, at 17V, the current should not exceed 2A to stay within the 35W/50W power limit.
  • Heat Dissipation: When operating above 3A or 35W, enhanced heat dissipation (e.g., active cooling with a fan) is strongly recommended to prevent overheating.
  • Input Undervoltage Protection: Be aware that the input undervoltage protection (default 4.8V) will disconnect the output if the voltage at the module's input terminals drops below this threshold. Consider voltage drop across input wires, especially with high input currents.

10. User Tips

  • This module can be effectively powered by a computer power supply (PC BP) for various applications.
  • The maximum current (4A) and voltage (30V) are software-limited. Modifying hardware components will not increase these limits but may improve reliability.
  • For sustained high-power operation, consider adding active cooling (a small fan) directed at the heatsink to prevent the module from reaching high temperatures (e.g., 90°C).
  • The module can be used to charge various battery types, including Li-ion, NiCd, and NiMH, by setting the appropriate voltage and current limits.
  • The module saves the last set voltage and current parameters, so it will start with these settings upon power-up.
  • It can serve as a versatile laboratory power supply for hobbyists and professionals.
  • When testing LEDs, ensure you know the LED's forward voltage and current requirements (check its datasheet) to avoid damage.

11. Troubleshooting

Q: The output voltage does not adjust, and the 'CC' indicator light is on.
A: This indicates the module is operating in Constant Current (CC) mode. The output voltage is being limited by the set current limit and the connected load's resistance. To adjust the voltage, you must either increase the current limit or reduce the load resistance until the 'CC' indicator turns off, allowing the module to operate in Constant Voltage (CV) mode.
Q: What happens if the input voltage exceeds 30V?
A: The module has an adjustable input undervoltage protection (LUP) and output overvoltage protection (OUP). While OUP is for the output, exceeding the input voltage range of 5-30V can potentially damage the module if not properly protected or if the protection threshold is set too high. Always operate within the specified input voltage range.
Q: Is there short-circuit protection?
A: Yes, the module features Output Overcurrent Protection (OCP) which is adjustable. If the output current exceeds the set limit, the output will shut off. However, as a general caution, direct short circuits should still be avoided as per the manual's warnings.
Q: Can I get more than 4A output if my power supply provides more current?
A: No, the module's output current is internally limited to a maximum of 4A (with enhanced cooling). Even if your input power supply can provide more current (e.g., 7A), the ZK-4KX module will not output more than its specified maximum of 4A.
Q: The module gets very hot during operation.
A: High temperatures can occur during prolonged operation at higher loads (above 3A or 35W). It is recommended to enhance heat dissipation by adding a small fan directed at the heatsink. Ensure proper airflow around the module.
Q: The display shows incorrect voltage/current readings.
A: You can use the calibration function (Section 8) to fine-tune the voltage and current readings for improved accuracy. Ensure you follow the calibration notes regarding minimum voltage and current for accurate results.

12. Maintenance

  • Cleaning: Keep the module clean and free from dust and debris. Use a soft, dry cloth for cleaning.
  • Environment: Operate the module in a dry, well-ventilated environment, away from direct sunlight, moisture, and extreme temperatures.
  • Heat Dissipation: Regularly check the heatsink for dust buildup. If operating at higher loads, ensure any additional cooling fans are functioning correctly.
  • Connections: Periodically inspect all wiring connections to ensure they are secure and free from corrosion.

13. Warranty and Support

For any issues or technical support, please contact the seller or manufacturer. Keep your purchase records for warranty claims. Specific warranty terms and conditions may vary by region and seller.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.