AISET NG6000-2

Contents

AISET NG Series Temperature Controller User Manual

Model: NG6000-2

1. Overview

The AISET NG series is a reliable, cost-effective digital temperature controller, designed for temperature measurement and automatic control in industrial workshops, production lines, laboratories and general automation equipment. It features simple operation, stable performance, high control accuracy and strong adaptability, widely applied in various heating, cooling and constant temperature control scenarios, fully complying with EU safety standards (EMC, LVD, WEEE directives) and AliExpress EU compliance requirements.

Front view of the AISET NG6000-2 temperature controller with digital display showing PV and SV values.

Figure 1: AISET NG6000-2 Front Panel

2. Product Warning / Safety Information

Important Safety Warnings - Read carefully before use to avoid injury, equipment damage, or non-compliance with EU regulations and AliExpress requirements.

  • This product is for industrial use only, not for household use. Keep out of reach of children and untrained personnel to prevent accidents.
  • WARNING: Always turn off the power supply before wiring, maintenance, disassembly or cleaning to prevent electric shock and equipment damage.
  • WARNING: Do not use the product beyond the rated parameters (voltage, temperature, load), which may cause fire, electric shock or permanent product damage.
  • WARNING: Avoid installing the controller in flammable, explosive, humid, dusty or corrosive environments to eliminate potential safety hazards.
  • WARNING: The controller must be grounded correctly in accordance with EU EMC and LVD directives; mandatory grounding is required for safe use and compliance with AliExpress requirements.
  • WARNING: Do not modify, disassemble or repair the product without authorization; any unauthorized operation will void the warranty and may violate EU regulations.
  • WARNING: In case of abnormal operation (smoke, peculiar odor, overheating or display failure), turn off the power immediately and stop using it, then contact professional maintenance personnel.
  • WARNING: Disposal of this product must comply with EU WEEE directives; do not discard it as household waste. Please hand it over to qualified recycling institutions.

3. Key Specifications

ItemParameter
Measurement Range-50°C ~ 999°C
Control Accuracy±0.1°C
Input SignalThermocouple (K/J/T/E), RTD (PT100)
Output ModeRelay output, SSR drive (optional)
Operating VoltageAC 100~240V, 50/60Hz (Complies with EU LVD directive)
Working Temperature0°C ~ 50°C
Protection ClassIP40
Product label showing detailed specifications including model NG-6401V-3(N), range 0-400°C K 0.5 level, supply 220V±10% 50Hz±1Hz, and Made in China SYT Instrument Inc.

Figure 2: Product Specification Label

4. Setup

4.1 Power On

Connect the power supply according to the wiring diagram (ensure correct grounding to meet EU compliance), then turn on the power switch. The AISET NG controller will automatically display the current measured temperature after power-on, allowing quick monitoring of real-time temperature status.

4.2 Wiring Instructions

Please turn off the power before wiring to avoid electric shock. The basic wiring of the AISET NG series is as follows (please refer to the product label for specific details to ensure correct connection and EU compliance for AliExpress):

  • Power Terminal (L/N): Connect to AC 100~240V power supply, ensuring stable power input to avoid equipment malfunctions.
  • Input Terminal (IN): Connect to thermocouple or RTD temperature sensor, ensuring tight connection for accurate signal transmission.
  • Output Terminal (OUT): Connect to the load (such as heater, cooler, etc.), and match the load type with the controller's output mode.
  • Ground Terminal (PE): Mandatory grounding (complies with EU safety regulations) to ensure safe use and prevent electrical hazards, which is required for AliExpress EU sales.

WARNING: Wrong wiring (especially no grounding) may cause electric shock, fire or product damage, violate EU regulations, and fail to meet AliExpress requirements. Please double-check the wiring before power-on.

Side view of the temperature controller showing a detailed wiring diagram label with terminals numbered 1 through 10. Connections include Ground, Power (L, N), Output (OUT), Alarm (ALM), and Thermocouple (TC).

Figure 3: Wiring Diagram

Rear view of the terminal block on the temperature controller, showing screw terminals for wiring connections.

Figure 4: Terminal Block

5. Operating Instructions

5.1 Set Target Temperature

  1. Press the "SET" key once, the display will flash, and you will enter the target temperature setting mode.
  2. Press the "▲" (up) or "▼" (down) key to adjust the target temperature to your required value, with intuitive operation and precise step adjustment.
  3. Press the "SET" key again to confirm and exit the setting mode, and the NG series controller will start automatic temperature control immediately.

5.2 Display Introduction

  • Normal mode: The left display shows the current measured temperature, and the right display shows the target temperature, with a clear and easy-to-read interface.
  • Setting mode: The flashing display indicates the parameter being set (only the target temperature is adjustable in simple operation, reducing complexity).
  • Alarm mode: The alarm indicator will light up when the temperature exceeds the set range (optional function, ensuring safe operation).

6. Maintenance

  • Install the NG series controller in a dry and ventilated place, away from high temperature, humidity, strong electromagnetic interference and flammable/explosive materials.
  • Regularly check the wiring, sensor connection and controller status to ensure stable operation, EU compliance and meet AliExpress requirements.
  • Clean the controller surface with a dry, soft cloth; do not use corrosive cleaners to avoid damaging the product.
  • CAUTION: If the controller fails, turn off the power immediately and contact professional maintenance personnel; do not attempt to repair it yourself to avoid safety risks.

7. Troubleshooting

If you encounter issues with your AISET NG Series Temperature Controller, first review the wiring and ensure all connections are secure and correct. Verify that the power supply is within the specified range and that the sensor is properly connected and functioning. If the problem persists after checking these basic points, and especially if you observe abnormal operation (smoke, peculiar odor, overheating, or display failure), immediately turn off the power and contact professional maintenance personnel. Do not attempt to repair the unit yourself.

8. User Tips

No specific user tips were available from reviews or Q&A for this product. Always refer to the detailed instructions for optimal performance and safety.

9. Warranty and Support

The AISET NG series temperature controller provides a 12-month warranty from the date of delivery. Under normal use and installation in accordance with this manual (and EU regulations, AliExpress requirements), free repair or replacement service is provided for defects caused by materials or workmanship. The warranty does not cover damage caused by improper operation, wrong wiring, unauthorized disassembly, non-compliance with EU regulations or external factors.

For detailed operation steps, parameter settings, and advanced functions, please refer to the full-version manual. A PDF version of the user manual can be found here.

Brand: AISET
Series: NG Temperature Controller
EU Compliance: Meets EU EMC, LVD and WEEE directives (Fully Complies with AliExpress EU Sales Requirements)

© 2023 AISET. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.