1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the Taidacent High Performance Stability Serial to CAN Converter Adapter. This compact module facilitates two-way data communication between serial devices (RS232/RS485) and CAN bus networks, offering high performance and stability for industrial and embedded applications.
2. Product Overview
2.1 Key Features
- Two-way data communication between CAN and RS232/RS485.
- Interface electrostatic protection and surge protection.
- Excellent EMC performance.
- 14 groups of configurable filters.
- Three working modes: transparent conversion, transparent with logo conversion, and format conversion.
- Offline detection and automatic recovery functions.
- Complies with CAN2.0B specification, compatible with CAN2.0A.
- Complies with ISO11898-1/2/3.
- CAN baud rate support: 10kbps ~ 1000kbps.
- Serial port baud rate support: 1200 ~ 460800bps.
- CAN buffer up to 1000 frames to ensure no data loss.
- High-speed conversion capabilities.
2.2 Package Contents
- Taidacent Serial to CAN Converter Adapter
- (Optional) 12V 1A Power Adapter (depending on selected SKU)
2.3 Physical Description


3. Specifications
| Parameter | Value |
|---|---|
| Power Supply | DC 5-36V |
| Power Consumption | < 0.2W |
| CPU | 32-bit high-performance processor |
| CAN Interface | Electrostatic protection, surge protection, excellent EMC performance |
| RS232 Interface | DB9 female, baud rate 1200 ~ 460800bps |
| RS485 Interface | ESD protection, 5.08mm terminal, baud rate 1200 ~ 460800bps |
| CAN Baud Rate | 10kbps ~ 1000kbps |
| Operating Temperature | Industrial grade: -40 ~ 85 ℃ |
| Storage Temperature | -65 ~ 165 ℃ |
| Humidity Range | 5 ~ 95% relative humidity |
4. Setup and Wiring
4.1 Power Connection
The module requires a DC 5-36V power supply. Connect the positive lead to VCC and the negative lead to GND on the green terminal block.

4.2 RS232 Interface Connection
The RS232 interface uses a DB9 female connector. Connect your RS232 device using a standard male serial cable. The pin definitions are as follows:

- Pin 2: TX (Transmit Data)
- Pin 3: RX (Receive Data)
- Pin 5: GND (Ground)
4.3 RS485 Interface Connection
The RS485 interface is provided via a 5.08mm green terminal block. Connect your RS485 device to the A and B terminals.

4.4 CAN Interface Connection
The CAN interface is also led out by a 5.00mm green terminal block. Connect your CAN bus to CAN_H and CAN_L.
CAN Bus Termination: According to the ISO 11898 specification, it is recommended to add 120 Ohm terminal matching resistors at both ends of the CAN bus network to enhance communication reliability. This module includes a selectable 120 Ohm termination resistor.
- To enable the internal 120 Ohm termination resistor, connect the RS terminal to the CAN_L terminal with a wire.
- If external termination is used or no termination is required at this node, leave the RS terminal disconnected.

5. Operation
5.1 LED Indicators
The module features four LED indicators to provide status information:
| Indicator | Color | Status | Meaning |
|---|---|---|---|
| PWR | Red | Steady On | System power is normal |
| PWR | Red | Off | System power is abnormal |
| RUN | Green | Flashing (~1Hz) | System running normally |
| RUN | Green | Steady On | CAN bus abnormal |
| COM | Green | Flashing | RS232/RS485 data received |
| CAN | Green | Flashing | CAN data received |
5.2 Configuration Software
The module's parameters can be configured using the "Intelligent Embedded IoT CAN to Serial Configuration Software" via the RS232 or RS485 interface.

Configuration Steps:
- Ensure you know the last successfully configured RS232/RS485 baud rate of the module. If unknown, perform a factory reset (see Section 6.1). The factory default serial parameters are 115200 baud, 8 data bits, No parity, 1 stop bit (115200, 8, N, 1).
- Connect the module to your computer via RS232 or RS485.
- Launch the configuration software.
- In the software, select the appropriate "serial port number" (COM port) corresponding to your connection.
- Select the correct baud rate and other serial parameters that were previously configured on the module.
- Click "Open Serial Port".
- Click "Get Device Parameters" to retrieve the current settings from the module.
- Modify the desired parameters (e.g., CAN baud rate, working mode, filters).
- After making changes, click "Save Device Parameters".
- Restart the device for the new settings to take effect.
5.3 Working Modes
The converter supports three primary working modes:
- Transparent Conversion: Data is passed directly between serial and CAN interfaces without modification.
- Transparent with Logo Conversion: Data is passed transparently, but with an added identifier or "logo" for easier identification.
- Format Conversion: Data is converted between specific serial and CAN message formats as defined in the configuration.
6. Troubleshooting
6.1 Factory Reset
If you encounter issues with configuration or cannot connect to the device due to incorrect settings, you can restore the module to its factory default parameters:
- Locate the "CFG" button on the module (refer to Figure 3).
- Press and hold the "CFG" button for approximately 5 seconds.
- Release the button after the three green indicator lights (RUN, COM, CAN) flash simultaneously.
- The module will now be reset to factory defaults (serial parameters: 115200, 8, N, 1).
6.2 Common Issues and Solutions
- No Power (PWR LED Off): Check power supply connections (VCC, GND) and ensure the input voltage is within the DC 5-36V range.
- RUN LED Steady On: Indicates a CAN bus abnormality. Check CAN_H and CAN_L connections, bus termination, and the integrity of the CAN network.
- No Data Transmission (COM/CAN LEDs not flashing):
- Verify serial port and CAN bus connections.
- Ensure baud rates and other communication parameters are correctly configured in the software and match connected devices.
- Check for correct RS485 A/B polarity.
- Configuration Software Connection Issues:
- Confirm the correct COM port is selected.
- Ensure the serial parameters (baud rate, data bits, parity, stop bits) in the software match the module's current settings. If unsure, perform a factory reset.
- Check the physical RS232/RS485 connection.
7. User Tips
- Always double-check wiring connections before applying power to prevent damage.
- For reliable CAN communication, ensure proper 120 Ohm termination at both ends of the bus.
- When configuring, save your settings frequently, especially after making significant changes.
- Keep the configuration software handy for quick parameter adjustments.
8. Maintenance
The Taidacent Serial to CAN Converter Adapter is designed for robust operation with minimal maintenance. To ensure longevity and optimal performance:
- Keep the device clean and free from dust and debris.
- Avoid exposing the module to extreme temperatures, high humidity, or corrosive environments.
- Ensure proper ventilation if installed in an enclosed space.
- Regularly check all cable connections for secure fit.
9. Support
For technical assistance, further documentation, or inquiries, please contact your vendor or the manufacturer directly. Provide your product model number (ZC-RCAN-IC311adapter-0110) and a detailed description of your issue for efficient support.