Introduction
This manual provides detailed instructions for the safe and effective use of your Brother Analog Multimeter models HD-470A, HD-390A, HD-390A+, and HD-390D. These high-precision mechanical pointer multimeters are designed for electricians and home maintenance tasks, offering various measurement capabilities including AC/DC voltage, DC current, and resistance.

Safety Information
Always observe safety precautions when using electrical testing equipment. Failure to do so may result in injury or damage to the multimeter or equipment under test.
- Ensure the multimeter is in good working condition before use.
- Do not exceed the maximum input values for each range.
- Always disconnect power to the circuit before making resistance or current measurements.
- Use caution when working with live circuits.
- Replace batteries and fuses with the specified types only.
- Do not operate the multimeter if it appears damaged or if the case is open.
- The HD-390A+ model features full protection, offering enhanced safety against overloads.
Product Overview
The Brother analog multimeters are designed for various electrical measurements. Each model features a clear analog display, a rotary switch for function and range selection, and input jacks for test leads.
Front Panel Components (Common to all models):
- Analog Display: Shows measurement readings via a pointer on a calibrated scale.
- Rotary Switch: Selects the measurement function (DCV, ACV, DCmA, Resistance, Battery Test, Transistor Test) and range.
- Input Jacks:
- COM (Common): Negative input jack, typically for the black test lead.
- VΩmA+: Positive input jack for voltage, resistance, and low current measurements, typically for the red test lead.
- +10A: Positive input jack for high current (10A) measurements.
- 0Ω ADJ (Zero Ohm Adjustment): Knob used to zero the resistance reading before measurement.
- Battery Test Points: Dedicated points for testing 1.5V and 9V batteries (on HD-470A, HD-390A, HD-390A+).
- Transistor Test Socket (NPN/PNP, hFE & LED): For testing transistors and LEDs.
Back Panel Components:
- Battery Cover: Secures the internal batteries.
- Tilt Stand: Allows the multimeter to be angled for easier viewing.
Model Specific Views:








Specifications
Below are the detailed specifications for each multimeter model:
Brother HD-470A
| Measurement | Range |
|---|---|
| AC Voltage | 10V, 50V, 250V, 1000V |
| DC Voltage | 0.1V, 2.5V, 10V, 50V, 250V, 1000V |
| DC Current | 50µA, 2.5mA, 25mA, 250mA, 10A |
| Resistance | 1Ω, 10Ω, 100Ω, 1KΩ, 10KΩ |
| Battery Test | 1.5V, 9V |
| Environmental Conditions | 23°C ± 5°C, Humidity <75% RH |
| Working Range | 0°C ~ 40°C, Humidity <90% RH |
| Size | 160mm x 105mm x 40mm |
Brother HD-390A
| Measurement | Range |
|---|---|
| AC Voltage | 10V, 50V, 250V, 1000V |
| DC Voltage | 0.1V, 2.5V, 10V, 50V, 250V, 1000V |
| DC Current | 50µA, 2.5mA, 25mA, 250mA, 10A |
| Resistance | 1Ω, 10Ω, 100Ω, 1KΩ, 10KΩ, 100KΩ |
| Battery Test | 1.5V, 9V |
| Environmental Conditions | 23°C ± 5°C, Humidity <75% RH |
| Working Range | 0°C ~ 40°C, Humidity <90% RH |
| Size | 160mm x 105mm x 40mm |
Brother HD-390A+
| Measurement | Range |
|---|---|
| Protection | Full Protection |
| AC Voltage | 10V, 50V, 250V, 1000V |
| DC Voltage | 0.1V, 2.5V, 10V, 50V, 250V, 1000V |
| DC Current | 50µA, 2.5mA, 25mA, 250mA, 10A |
| Resistance | 1Ω, 10Ω, 100Ω, 1KΩ, 10KΩ, 100KΩ |
| Battery Test | 1.5V, 9V |
| Environmental Conditions | 23°C ± 5°C, Humidity <75% RH |
| Working Range | 0°C ~ 40°C, Humidity <90% RH |
| Size | 160mm x 105mm x 40mm |
Brother HD-390D
| Measurement | Range |
|---|---|
| AC Voltage | 0.1V, 0.5V, 2.5V, 10V, 50V, 250V, 1000V |
| DC Voltage | 0.1V, 0.5V, 2.5V, 10V, 50V, 250V, 1000V |
| AC Current | 0.05mA, 0.25mA, 2.5mA, 25mA, 250mA, 10A |
| DC Current | 0.05mA, 0.25mA, 2.5mA, 25mA, 250mA, 10A |
| Resistance | 1Ω, 10Ω, 1KΩ, 10KΩ, 100KΩ |
| Battery Test | 1.5V, 9V |
| Environmental Conditions | 23°C ± 5°C, Humidity <75% RH |
| Working Range | 0°C ~ 40°C, Humidity <90% RH |
| Size | 160mm x 105mm x 40mm |
Setup
1. Battery Installation
The multimeter requires batteries for operation (1.5V and 9V, not included). To install or replace batteries:
- Ensure the multimeter is OFF and test leads are disconnected.
- Locate the battery cover on the back of the unit.
- Slide or unscrew the battery cover to open it.
- Insert the required 1.5V and 9V batteries, observing correct polarity (+/-).
- Securely close the battery cover.

2. Connecting Test Leads
Connect the test leads to the appropriate input jacks:
- Insert the black test lead into the COM (Common) jack.
- For most measurements (voltage, resistance, low current), insert the red test lead into the VΩmA+ jack.
- For high current (10A) measurements, insert the red test lead into the +10A jack.

Operating Instructions
Before taking any measurement, ensure the test leads are correctly connected and the rotary switch is set to the appropriate function and range.
1. Measuring DC Voltage (DCV)
- Connect the black lead to COM and the red lead to VΩmA+.
- Set the rotary switch to the desired DCV range (e.g., 10V, 50V, 250V, 1000V). Always start with a higher range if the voltage is unknown.
- Connect the test leads in parallel across the component or circuit to be measured.
- Read the DCV value from the appropriate scale on the analog display.
2. Measuring AC Voltage (ACV)
- Connect the black lead to COM and the red lead to VΩmA+.
- Set the rotary switch to the desired ACV range (e.g., 10V, 50V, 250V, 1000V). Always start with a higher range if the voltage is unknown.
- Connect the test leads in parallel across the AC source or component.
- Read the ACV value from the appropriate scale on the analog display.
3. Measuring DC Current (DCmA / 10A)
- For low current (mA): Connect the black lead to COM and the red lead to VΩmA+.
- For high current (10A): Connect the black lead to COM and the red lead to +10A.
- Set the rotary switch to the desired DCmA or 10A range. Always start with a higher range.
- WARNING: Connect the multimeter in series with the circuit. Ensure power is off before connecting the leads in series.
- Apply power to the circuit.
- Read the DC current value from the appropriate scale.
4. Measuring Resistance (Ω)
- Ensure the circuit or component is completely de-energized.
- Connect the black lead to COM and the red lead to VΩmA+.
- Set the rotary switch to an appropriate resistance range (e.g., X1, X10, X100, X1K, X10K, X100K).
- Short the red and black test leads together.
- Adjust the 0Ω ADJ knob until the pointer reads zero on the resistance scale.
- Connect the test leads across the component to be measured.
- Read the resistance value from the resistance scale and multiply by the selected range multiplier.
5. Battery Test (1.5V / 9V)
(Applicable to HD-470A, HD-390A, HD-390A+ models)
- Connect the black lead to COM and the red lead to VΩmA+.
- Set the rotary switch to the 1.5V or 9V battery test position.
- Connect the test leads to the positive and negative terminals of the battery.
- Read the battery condition from the designated battery scale.
6. Transistor (hFE) and LED Test
- Set the rotary switch to the hFE or LED test position.
- Insert the transistor leads (Emitter, Base, Collector) into the corresponding sockets (NPN or PNP) on the front panel.
- Read the hFE value from the display.
- For LED testing, insert the LED leads into the designated LED test points. The LED should light up if functional.
Maintenance
1. Cleaning
- Wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents.
- Keep the test leads clean and free from damage.
2. Battery Replacement
When the battery test indicates low power or the multimeter functions become erratic, replace the batteries as described in the "Setup" section.
3. Fuse Replacement
(Applicable to models with fused protection, e.g., HD-470A, HD-390A, HD-390A+ which mention "10A/250V FUSED")
If the current measurement function stops working, the fuse may need replacement. Refer to the back panel for fuse access, typically located under the battery cover or a separate fuse compartment. Replace with a fuse of the exact same type and rating (e.g., 10A/250V).
Troubleshooting
- No reading / Pointer not moving:
- Check if the multimeter is OFF.
- Ensure batteries are correctly installed and have sufficient charge.
- Verify test leads are properly connected to the correct jacks and the circuit.
- Check if the rotary switch is set to the correct function and range.
- For resistance measurements, ensure 0Ω adjustment is performed.
- Incorrect readings:
- Ensure the correct range is selected.
- Verify proper connection to the circuit (series for current, parallel for voltage).
- Check for damaged test leads.
- Ensure the component under test is isolated if measuring resistance.
- Current measurement not working:
- Check the fuse (if applicable).
- Ensure the red lead is connected to the correct current jack (VΩmA+ for low current, +10A for high current).
User Tips
- Always start with the highest range when measuring an unknown voltage or current to prevent damage to the multimeter.
- For precise resistance measurements, always perform the 0Ω adjustment before testing.
- When measuring resistance, ensure the component is not connected to any power source and is isolated from the circuit to avoid false readings or damage.