1. Product Overview
The HM Digital AquaPro AP-2 is a handheld water quality tester designed to accurately measure electrical conductivity (EC) and temperature in aquatic environments. This device features automatic temperature compensation (ATC), digital calibration, and a data-hold function, making it suitable for various applications from home use to laboratory testing. This manual provides detailed instructions for its use, maintenance, and troubleshooting.

2. Components and Controls
Familiarize yourself with the main components and controls of your AquaPro AP-2 tester:

- Display Screen: Large LCD screen showing EC (µS) and temperature (°C/°F) readings.
- Power Button: Turns the device on and off.
- Mode Button (▲): Used for calibration, temperature scale selection, and navigating menus.
- HOLD Button (▼): Freezes the current reading on the display. Also used for navigating menus.
- Battery Case: Houses the CR2032 button cell battery.
- Electrode (Metal Pins): The sensor for measuring electrical conductivity.
- Thermistor: Measures water temperature.
- Protective Cap: Covers and protects the electrodes and thermistor when not in use.
3. Setup
3.1 Preparatory Work
- Inspection: Before first use, inspect the tester for any visible damage.
- Battery Installation: The AquaPro AP-2 requires one 3V button cell (CR2032) battery. Open the battery case (refer to Figure 2) and insert the battery, ensuring correct polarity. Note: Batteries are not included due to air freight restrictions.
- Power Source: Ensure the power supply is stable if connecting to an external power source (though typically battery-operated).
- Calibration Check: The AquaPro is factory calibrated with a 700 µS solution. It is recommended to check calibration periodically.
4. Operating Instructions
4.1 Testing Procedure
- Power On: Press the POWER button to switch on the instrument. The system will initialize and display the main interface.
- Select Parameter (if applicable): For this 2-in-1 model, EC and temperature are measured simultaneously. To switch between °C and °F for temperature, press and hold the MODE button.
- Immerse Sensor: Remove the protective cap. Immerse the sensor section (electrodes and thermistor) of the water quality monitor into the water sample to be tested, ensuring full contact between the sensor and the water. Do not immerse above the indicated water level.
- Read Results: Wait a few seconds for the reading to stabilize. The instrument will automatically measure and display the EC and temperature results on the LCD screen.
- Data Hold: To freeze the current reading on the display, press the HOLD button. Press it again to release the hold function.
- Power Off: The device has an auto-off function to conserve battery. Alternatively, press the POWER button to manually turn it off.


4.2 Digital Calibration
The AquaPro AP-2 features digital calibration via push buttons, eliminating the need for a screwdriver. For detailed calibration steps, refer to the full user manual PDF.
4.3 Understanding Water Conductivity
Electrical conductivity (EC) is a measure of the total amount of dissolved solids, which reflects the conductivity of total ions in the water. This indicates the quality of the reaction water.

Conversion: To convert µS (micro-Siemens) to mS (milli-Siemens), divide by 1000 (e.g., 1000 µS = 1 mS).
4.4 Product Demonstration Video
Watch a brief demonstration of the HM Digital AquaPro AP-2 water quality tester.
5. Maintenance
5.1 Operating Environment
The water quality monitor is intended for indoor use only. Avoid exposure to direct sunlight or adverse weather conditions. Additionally, refrain from using it near pollution sources to prevent interference with test results.
5.2 Sensor Maintenance
Maintaining the cleanliness of the sensor assembly is crucial for ensuring accurate measurements. After each use, clean the sensor using appropriate methods (e.g., rinsing with distilled water) to ensure its surface remains free of contaminants. Always replace the protective cap after use.
5.3 Power Management
Regularly check battery levels. Should a low-battery warning occur during operation, promptly replace the CR2032 battery. Remove batteries during prolonged periods of non-use to prevent leakage and damage to the instrument.
5.4 Impact Prevention
As a precision instrument, the water quality monitor must be protected from impacts, drops, or compression during use to prevent damage.
6. Troubleshooting
Below are common faults and their suggested solutions:
| Problem | Suggested Solution |
|---|---|
| Display shows garbled characters or no display | Check the instrument's battery level and attempt to restart the device. Replace battery if low. |
| Inaccurate or unstable test results | First, verify that the sensor is clean and functioning correctly. If necessary, recalibrate the device and ensure the measurement environment is stable. |
| Instrument fails to power on | Confirm that the power supply is properly connected. If using batteries, ensure they are fully charged or replace them before attempting to power on again. |
7. Specifications
| Parameter | Value |
|---|---|
| Model Number | AP-2 |
| Display Type | DIGITAL |
| EC Range | 0-9999 µS (µS/cm) |
| Temperature Range | 0-80 °C; 32-176 °F |
| EC Resolution | 1 µS |
| Temperature Resolution | 0.1 °C/F |
| Accuracy | +/- 2% |
| Calibration | Digital calibration by push button (factory calibrated with 700 µS solution) |
| Automatic Temperature Compensation (ATC) | Yes |
| Housing | Water-resistant |
| Auto-off Function | Yes |
| Data-hold Function | Yes |
| Low-battery Indicator | Yes |
| Power Source | 1 x 3V button cell (model CR2032) |
| Dimensions | 15 x 2.8 x 1.3 cm (5.9 x 1.1 x 0.5 inches) |
| Certification | CE |
| Patent | U.S. PATENT D602,384S (Magnetic body patent pending) |
8. User Tips
- Regular Cleaning: Always clean the electrodes with distilled water after each use to maintain accuracy and prolong sensor life.
- Battery Life: Keep spare CR2032 batteries on hand, as they are not included with the device. Remove batteries if storing the device for extended periods.
- Calibration: While factory calibrated, recalibrate periodically or if you suspect inaccurate readings, especially for critical applications.
- Handling: Treat the device as a precision instrument; avoid dropping or subjecting it to strong impacts.
9. Warranty and Support
For detailed warranty information and further support, please refer to the official documentation. A comprehensive user manual is available in PDF format:
If you encounter any issues not covered in this manual or require further assistance, please contact customer support.