1. Introduction
This manual provides essential information for the installation, operation, and maintenance of the TECNR FX3U-32MT and FX3U-30MR series Programmable Logic Controllers (PLCs). These industrial control boards are designed for general application and are compatible with FX1N and FX2N series PLCs. They feature various input/output configurations, analog capabilities, and communication options including RS485 and CAN, along with a Real-Time Clock (RTC) in some variants.
Figure 1: TECNR FX3U-32MT/30MR PLC Industrial Control Board overview. Shows the board with terminal blocks, a DB9 connector, and labels indicating 16 inputs and 16/10 outputs depending on the model.
2. Specifications
The FX3U series offers different configurations. Key specifications for the FX3U-30MR and FX3U-32MT models are detailed below:
| Feature | FX3U-30MR | FX3U-32MT |
|---|---|---|
| Output Type | Relay | Transistor |
| Input Voltage | 24V DC | 24V DC |
| Output Current | 5A | 1A |
| Input Points | 16 | 16 |
| Output Points | 14 | 16 |
| Analog Input (AD) | 6AD | 6AD |
| Analog Output (DA) | 2DA | 2DA |
| High Speed Counting | 6 channel 3K (60K optional) | 6 channel 3K (60K optional) |
| Pulse Output | No | 4 channel 100K (4 channel 12K optional) |
| Floating Point | Support | Support |
| Step Motor | Not Support | Support |
| Memory Capacity | 8000 steps | 8000 steps |
| Download Type | Download directly | Download directly |
| RS485 | Optional | Optional |
| MODBUS | Optional | Optional |
| Support Text Display | YES | YES |
| Support HMI Touch Screen | YES | YES |
| Software | GX Developer OR GX Works2 | GX Developer OR GX Works2 |
Table 1: Detailed specifications for FX3U-30MR and FX3U-32MT PLC models.
Figure 2: Visual comparison of MR (Relay) and MT (Transistor) output types on the PLC board.
3. Setup Instructions
3.1 Unpacking
Carefully remove the PLC industrial control board from its packaging. Inspect for any visible damage during transit. Ensure all components are present.
3.2 Power Supply Connection
The PLC requires a 24V DC power input. Connect the DC 24V positive to the '+' terminal and the DC 24V negative to the '-' terminal on the board. An external 24V 2A 50W switch power supply is recommended (see Figure 3).
Figure 3: Example of a compatible 24V 2A 50W Switch Power Supply.
3.3 Wiring Diagrams
Refer to the specific wiring diagrams for your model (FX3U-30MR or FX3U-32MT) to ensure correct connections for inputs, outputs, and communication interfaces.
FX3U-30MR Wiring Diagram:
Figure 4: Wiring diagram for the FX3U-30MR model. Key connections include DC 24V positive/negative, COM (switch pack common side), X00-X017 (switch pack input), A+/B- RS485 interface, CAN communication interface, COMs (public side of Y0-Y3, Y10-Y13, Y14-Y15), DA0-DA1 (analog output 0-10V), AD0-AD2 (analog input 0-10V), AD3-AD5 (analog input 0-20mA), and RS232 communication interface.
- DC+ / DC-: DC 24V positive and negative input.
- COM: Switch pack common side.
- X00-X017: Switch pack input. These are NPN inputs, low level active.
- A+, B-: RS485 interface.
- CAN, CNA: CAN communication interface (optional).
- COM0, COM1, COM2, COM3: Public side of Y0-Y3, Y4-Y7, Y10-Y13, Y14-Y15 respectively. Connect 0V only; do not connect to AC or 220V.
- DA0-DA1: Analog output (voltage 0-10V).
- AD0-AD2: Analog input (voltage 0-10V).
- AD3-AD5: Analog input (current 0-20mA).
- RS232: Communication interface (DB9 connector).
FX3U-32MT Wiring Diagram:
Figure 5: Wiring diagram for the FX3U-32MT model. Similar connections to the FX3U-30MR, with specific details for transistor outputs. Note: The output can only be connected to DC direct load (within 3A); do not connect AC or AC220V.
- RS232 Communication Pin Definition: GND (5), RX (3), TX (2).
- DAO-DA1: Voltage output (0-10V).
- AD3-AD5: Current input (4-20mA).
- AD0-AD2: Voltage input (0-10V).
- GND public end.
- Running switch.
- CAN communication (optional).
- RS485 communication (optional).
- Output terminals: Connect to 24V (positive) and 0V (negative) for loads.
Important Note for Outputs: The output can only be connected to DC direct load (within 3A). Do not connect to AC or AC220V.
3.4 Communication Cables
The product does not include programming cables by default. Customers requiring programming cables should acquire them separately. Common types include USB to RS232 and Male to Female DB9 serial cables.
Figure 6: Examples of serial cables (USB to RS232 and Male to Female DB9) used for PLC programming.
3.5 Software Installation
To program the PLC, you will need either GX Developer or GX Works2 software. Install the appropriate software on your PC according to the software's instructions.
4. Operating Instructions
Once the PLC is wired and powered, you can begin programming and operating it using the GX Developer or GX Works2 software.
- Connect the PLC to your PC: Use a compatible RS232 programming cable to connect the PLC's DB9 port to your computer.
- Launch Programming Software: Open GX Developer or GX Works2.
- Create/Load Program: Develop your ladder logic program or load an existing one.
- Configure Communication Settings: Ensure the software's communication settings match the PLC's (e.g., COM port, baud rate).
- Download Program: Download the compiled program from your PC to the PLC. The download type is direct.
- Monitor and Debug: Use the software's monitoring features to observe PLC status, input/output states, and debug your program.
- HMI Integration: If using an HMI touch screen, connect it to the PLC and configure the communication settings as required by the HMI software.
5. Maintenance
Proper maintenance ensures the longevity and reliable operation of your PLC industrial control board.
- Environmental Conditions: Ensure the PLC operates within its specified temperature and humidity ranges. Avoid exposure to excessive dust, moisture, corrosive gases, or strong electromagnetic interference.
- Cleaning: Periodically clean the exterior of the PLC with a soft, dry cloth. Do not use solvents or abrasive cleaners. Ensure ventilation openings are clear of obstructions.
- Wiring Integrity: Regularly check all wiring connections for tightness and signs of wear or corrosion. Loose connections can lead to intermittent operation or system failures.
- Firmware Updates: Check the manufacturer's website for any available firmware updates that may improve performance or address known issues.
- Backup Programs: Always maintain backup copies of your PLC programs on an external storage device.
6. Troubleshooting
This section provides guidance for common issues you might encounter.
- PLC Not Powering On:
- Verify the 24V DC power supply is correctly connected and providing the correct voltage.
- Check the power supply unit for proper operation.
- Communication Errors:
- Ensure the correct communication cable (RS232) is used and securely connected to both the PLC and the PC.
- Verify the communication settings (COM port, baud rate) in your programming software match the PLC's configuration.
- If using RS485 or CAN, ensure the correct optional module is installed and configured.
- Program Download Failure:
- Check for communication errors as described above.
- Ensure the program is compiled without errors in GX Developer or GX Works2.
- Verify the PLC is in programming mode if required by the software.
- Output Not Activating:
- Check the PLC program logic to ensure the output condition is met.
- Verify the output wiring is correct and the load is within the specified current limits (e.g., 3A for transistor outputs).
- Ensure the output is connected to a DC direct load only, not AC or AC220V.
7. User Tips
- Communication Options: This PLC uses RS232 communication by default. If your application requires RS485 communication, ensure you select the appropriate model variant that includes RS485 functionality.
- Real-Time Clock (RTC): Models specified with 'RTC' include a real-time clock feature, useful for applications requiring time-based operations.
- Accessory Purchase: Remember that programming cables and power supplies are typically sold separately. Plan to acquire these based on your specific setup needs.
8. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the seller's policies or contact the manufacturer directly. Keep your purchase records for any warranty claims.