TECNR FX3U-14MR FX3U-14MT

Contents

TECNR FX3U-14MR/MT PLC Industrial Control Board User Manual

Models: FX3U-14MR, FX3U-14MT

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the TECNR FX3U-14MR and FX3U-14MT PLC industrial control boards. These boards are compatible with FX1N and FX2N series PLCs and feature 8 digital inputs, 6 digital outputs, 6 analog inputs (6AD), and 2 analog outputs (2DA). Optional RS485 communication and Real-Time Clock (RTC) functionalities are available depending on the model.

FX3U-14MT/MR PLC industrial control board with 8 inputs, 6 outputs, 6AD, 2DA
Figure 1: FX3U-14MT/MR PLC Industrial Control Board Overview

2. Specifications

The following table details the key specifications for the FX3U-14MR (Relay Output) and FX3U-14MT (Transistor Output) models:

Detailed specification table for FX3U-14MR and FX3U-14MT PLC models
Figure 2: FX3U-14MR and FX3U-14MT Specifications
FeatureFX3U-14MRFX3U-14MT
Output TypeRelayTransistor
Input Voltage24V DC24V DC
Output Current5A1A
Input Points88
Output Points66
Analog Input6AD6AD
Analog Output2DA2DA
High-speed Counting6 channel 3K (2 channel 60K optional)6 channel 3K (2 channel 60K optional)
Pulse OutputNo2 channel 100K
Floating PointSupportSupport
Step MotorNot SupportSupport
Memory Capacity8000 steps8000 steps
Download TypeDownload directlyDownload directly
RS485OptionalOptional
MODBUSOptionalOptional
Support Text DisplayYESYES
Support HMI Touch ScreenYESYES
SoftwareGX Developer OR GX Works2GX Developer OR GX Works2

3. Setup and Wiring

Proper wiring is crucial for the safe and correct operation of the PLC board. Ensure all connections are secure and follow the diagrams below. The PLC operates on a 24V DC power supply.

3.1. FX3U-14MR Wiring Diagram

Wiring diagram for FX3U-14MR PLC showing power, load, RS232, RS485, analog I/O, and run switch connections.
Figure 3: FX3U-14MR Wiring Diagram

Key Connections for FX3U-14MR:

  • Power Supply: Connect 24V (positive) and 0V (negative) to the designated terminals.
  • Load: Connect your load to the relay output terminals.
  • RS232: Use the DB9 connector for RS232 communication. Pins are defined as TX (2), RX (3), and GND (5).
  • RS485 (Optional): Connect A+ and B- for RS485 communication interface.
  • Analog Inputs:
    • DA0-DA1: Voltage output (0-10V)
    • AD3-AD5: Current input (0-20mA)
    • AD0-AD5: Voltage input (0-10V)
    • GND: Analog public terminal
  • Run Switch: Located on the board for operational control.

3.2. FX3U-14MT Wiring Diagram

Wiring diagram for FX3U-14MT PLC showing power, load, RS232, RS485, analog I/O, and run switch connections. Note on DC load only.
Figure 4: FX3U-14MT Wiring Diagram

Key Connections for FX3U-14MT:

  • Power Supply: Connect 24V (positive) and 0V (negative) to the designated terminals.
  • Load: Connect your load to the transistor output terminals. Note: The output terminal can only be connected to DC load (within 3A). Do not connect AC or AC220V.
  • RS232: Use the DB9 connector for RS232 communication. Pins are defined as TX (2), RX (3), and GND (5).
  • RS485 (Optional): Connect A+ and B- for RS485 communication interface.
  • Analog Inputs:
    • DA0-DA1: Voltage output (0-10V)
    • AD3-AD5: Current input (0-20mA)
    • AD0-AD2: Voltage input (0-10V)
    • GND: Analog common terminal
  • Run Switch: Located on the board for operational control.

3.3. RTC Battery Location (for models with RTC)

Image showing the location of the RTC button battery on the back of the FX3U-14MT-RS485-RTC PLC card, requiring disassembly to access.
Figure 5: FX3U-14MT-RS485-RTC showing RTC battery location

For models equipped with Real-Time Clock (RTC) functionality, the button battery is located on the back of the PLC card. Disassembly of the casing is required to access and replace the RTC battery.

4. Operating Instructions

4.1. Programming Software

The PLC board can be programmed using either GX Developer or GX Works2 software. These are standard programming environments for Mitsubishi-compatible PLCs. Programs are downloaded directly to the PLC via the RS232 port.

4.2. Communication Interfaces

  • RS232: Standard communication port for programming and data exchange.
  • RS485 (Optional): For models with RS485, this interface allows for multi-drop communication with other devices.
  • MODBUS (Optional): Models with MODBUS support enable communication using the Modbus protocol.

4.3. Advanced Features

  • High-speed Counting: Supports 6 channels at 3KHz, with 2 channels optionally supporting 60KHz.
  • Pulse Output: FX3U-14MT models support 2 channels of 100KHz pulse output, suitable for controlling step motors.
  • Floating Point Operations: Both models support floating-point calculations.
  • HMI & Text Display Support: The PLC boards are designed to interface with Human Machine Interface (HMI) touch screens and text displays for user interaction and monitoring.

5. Maintenance

  • RTC Battery Replacement: If your model includes an RTC, the button battery may need replacement over time. As shown in Figure 5, access requires careful disassembly of the PLC casing. Ensure the device is powered off before attempting battery replacement.
  • Cleaning: Keep the PLC board clean and free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using liquids or abrasive cleaners.
  • Environmental Conditions: Ensure the PLC operates within its specified environmental conditions (temperature, humidity) to prevent damage and ensure longevity.
  • Firmware Updates: Periodically check for any available firmware updates from the manufacturer to ensure optimal performance and security.

6. Troubleshooting

Q: I cannot connect to the PLC with GX Developer or GX Works2, even with a COM port.
A: Ensure the correct programming cable (e.g., USB to RS232) is used and properly installed with its drivers. Verify the COM port settings (baud rate, data bits, stop bits, parity) in your software match the PLC's communication parameters. Check the physical connection of the cable. Sometimes, trying different baud rates or ensuring the PLC is powered on correctly can resolve connection issues.
Q: Can I expand the inputs and outputs?
A: Based on available information, these specific FX3U-14MR/MT models do not support direct expansion modules for additional inputs/outputs. Please refer to the specifications for the fixed I/O points.
Q: Is the programming cable included?
A: The programming cable is typically not included by default and must be purchased separately. You will need a USB to RS232 or a Male to Female DB9 serial cable for programming.
Q: Does it support HMI?
A: Yes, both FX3U-14MR and FX3U-14MT models support HMI (Human Machine Interface) touch screens and text displays.
Q: Will it work with Codesys?
A: These PLC boards are designed for compatibility with Mitsubishi FX series PLCs and are programmed using GX Developer or GX Works2. Compatibility with Codesys is not typically supported.

7. User Tips

  • Communication Options: The PLC is RS232 communication by default. If your application requires RS485 communication, ensure you select the appropriate model variant that includes RS485 functionality.
  • Real-Time Clock (RTC): If your model includes RTC, it means it has a built-in real-time clock function, useful for time-based operations in your automation projects.
  • Programming Cable: Remember that the programming cable is usually sold separately. Acquire a compatible USB to RS232 or Male to Female DB9 serial cable for programming.
  • Power Supply: Always use a stable 24V DC power supply for the PLC. An example of a suitable power supply is a 24V 2A 50W switch power supply.
24V 2A 50W Switch Power Supply, recommended accessory for the PLC board.
Figure 6: Example 24V 2A 50W Switch Power Supply
USB to RS232 serial cable, essential for programming the PLC board.
Figure 7: USB to RS232 Serial Cable

8. Warranty and Support

For technical support, troubleshooting assistance, or warranty inquiries, please contact the seller or manufacturer directly. Ensure you have your product model and purchase details available when seeking support.

© 2023 TECNR. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.