1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your OBO Hands A1 RFID Door Access Control System Kit. This system offers secure access control using RFID cards, passwords, or a combination of both. Please read this manual thoroughly before installation and operation to ensure proper functionality and safety.
The kit is designed for various door types including wooden, iron, and glass doors, with different lock and bracket options available to suit your specific needs.
2. Safety Information
- Always disconnect power before performing any installation or maintenance.
- Ensure all wiring is correctly connected according to the provided diagram to prevent damage to the system or electrical hazards.
- The access controller is surface waterproof and dustproof, but it is not IP65 rated. For outdoor installations, additional protection from direct rain and harsh weather conditions is recommended.
- Do not attempt to repair or modify the system components yourself. Refer to qualified personnel for service.
- Keep components away from excessive heat, moisture, and corrosive substances.
3. Package Contents
The OBO Hands A1 RFID Door Access Control System Kit includes the following core components. Specific lock and bracket types vary by kit selection:

Main components of the OBO Hands A1 RFID Door Access Control System Kit.
- Access Control Keypad (Model A1)
- Power Supply Control Unit
- Door Exit Button
- RFID Keyfobs (10 pieces, mixed colors)
- Selected Electric Lock (Magnetic Lock, Electric Strike Lock, or Electric Drop Bolt Lock)
- Optional Brackets (L, U, ZL) depending on door type and lock choice
Kit Variations:
- Kit3: Access Control Keypad + Power Supply + NC type Electric Strike Lock + Exit Button + 10 Keyfobs. Suitable for wooden and metal doors.
- Kit4: Access Control Keypad + Power Supply + Electric Drop Bolt Lock + Exit Button + 10 Keyfobs. Suitable for wooden, metal, and stainless steel doors.
- Kit5: Access Control Keypad + Power Supply + 180KG Electric Magnetic Lock + Exit Button + 10 Keyfobs. Suitable for wooden, metal, and glass frame doors.
- Kit6: Access Control Keypad + Power Supply + 180KG Magnetic Lock + U bracket + Exit Button + 10 Keyfobs. Suitable for frameless glass doors.
- Kit7: Access Control Keypad + Power Supply + 180KG Magnetic Lock + L bracket + Exit Button + 10 Keyfobs. Suitable for wooden and metal doors where an L bracket is needed.
- Kit8: Access Control Keypad + Power Supply + 180KG Magnetic Lock + ZL bracket + Exit Button + 10 Keyfobs. Suitable for wooden, metal, and glass doors that open inwards.
- Kit9: Access Control Keypad + Power Supply + Embedded 180KG Electric Magnetic Lock + Exit Button + 10 Keyfobs. Suitable for wooden, metal, and glass frame doors.
4. Specifications
4.1. Access Control Keypad (Model A1)

Dimensions and features of the A1 Access Control Keypad.
- User Capacity: 1000
- Card Reading Type: EM card (125KHz)
- Card Reading Distance: 1-5 cm
- Identification Methods: Card, Password, Card + Password
- Default Programming Password: 123456
- Unlocking Time: 5 seconds (adjustable)
- Doorbell Output: One-way wired doorbell output
- Working Voltage: DC 12V ± 10%
- Working Power Consumption: <100mA
- Working Temperature: 0°C ~ 60°C
- Dimensions: 113mm (L) x 70mm (W) x 20mm (H)
- Material: ABS flame-retardant casing

Internal components of the A1 Access Control Keypad.
4.2. Power Supply Control Unit

Dimensions and terminals of the Power Supply Control Unit.
- Material: Steel
- Output Power: 36W
- Input Frequency: 50-60Hz
- Input Voltage: 110-260VAC
- Output Voltage: DC12V/3A
- Working Temperature: -20°C to +65°C
- Time Delay: 0-15 seconds (adjustable)
- Relative Humidity: 0%-90% (non-condensing)
- Dimensions: 100mm (L) x 65mm (W) x 32mm (H)
4.3. Door Exit Button
- Material: Hard Plastic
- Maximum Power Rating: 36V DC 3A-5A output
- Supported Modes: NC Mode (Fail Safe) & NO Mode (Fail Secure)
- Dimensions: 86mm (L) x 86mm (W)
4.4. RFID Keyfobs
- Frequency: 125KHz
- Detection Range: 0-10cm
- Pre-programmed: Each card has a unique identity number.
4.5. Lock Specifications (Varies by Kit)

Dimensions of various electric lock types.
- Electric Strike Lock (Kit3):
- Working Voltage: 12V ± 10%
- Current: 200mA - 450mA
- Holding Force: 500kg
- Surface Temperature: Lower than room temperature +20°C
- Working Temperature: -30°C to +60°C
- Operating Humidity: 0~90% (non-condensing)
- Feature: Fail secure (NO), Fail safe (NC). NC type is default (Locked when power on, unlocked when power off).
- Material: Stainless steel
- Dimensions: 150mm (L) x 28mm (W) x 34mm (H)
- Electric Drop Bolt Lock (Kit4):
- Working Voltage: 12VDC
- Time Delay: 0s, 3s, 6s (adjustable)
- Working Current: Start state 1.2A; Persistent state 120mA
- Coil Type: Continuous working
- Security Type: Electric power lock, unlock
- Lock Core: Diameter 12.5mm stainless steel, extending length 15mm
- Locking Mode: Magnetic induction
- Unlock Mode: Fail Safe (Locked when power on, unlocked when power off)
- Dimensions: 150mm (L) x 34mm (W) x 28mm (H)
- 180KG Electric Magnetic Lock (Kit5, Kit6, Kit7, Kit8):
- Material: Aluminum alloy shell + iron plate
- Holding Force: 180KG/350lbs
- Working Voltage: DC12V
- Working Current: 380-430mA
- Humidity: 0 to 95%
- Working Temperature: -10°C to 55°C
- Working Mode: Power-on to lock, power-off to unlock (Fail Safe)
- Waterproof: Yes (can be installed outside, but additional protection from direct rain is recommended for the keypad).
- Dimensions: 172mm (L) x 40mm (W) x 21mm (H)
- Embedded 180KG Electric Magnetic Lock (Kit9):
- Holding Force: 180kg (350Lbs)
- Input Voltage: 12VDC
- Current: 12V/120mA
- Lock Dimensions: 192mm (L) x 33mm (W) x 20mm (H)
- Armature Plate Dimensions: 139mm (L) x 32mm (W) x 11mm (H)
5. Setup & Installation
Careful installation is crucial for the proper functioning of your access control system. It is recommended that installation be performed by a qualified technician.
5.1. General Installation Notes
- Identify your door type (wooden, metal, glass) and opening direction (inward/outward) to select the correct lock and bracket combination.
- Ensure all components are securely mounted.
- For outdoor installations, provide adequate shelter for the keypad and other components from direct weather exposure.
5.2. Wiring Diagram
The following diagram illustrates the general wiring connections for the access control system. Refer to this diagram carefully during installation.

Wiring Diagram for the Access Control System.
Wiring Terminal Descriptions:
| Component | Terminal | Description |
|---|---|---|
| Access Controller | 12V | Power Input (Positive) |
| GND | Power Input (Negative) | |
| PUSH | Exit Button Connection | |
| BELL+ | Doorbell Positive Output | |
| BELL- | Doorbell Negative Output | |
| Power Supply | CONTROL+ | Control Input (Positive) |
| CONTROL- | Control Input (Negative) | |
| PUSH | Exit Button Input | |
| GND | Ground | |
| NC | Normally Closed (for Fail Safe locks) | |
| NO | Normally Open (for Fail Secure locks) |
5.3. Component-Specific Installation
Access Control Keypad:
- Mount the keypad at a convenient height near the door.
- Connect the keypad's wiring harness to the corresponding terminals on the power supply and other components as per the wiring diagram.
- The keypad features a smart original chip for reliable performance.
Power Supply:
- Install the power supply in a secure, dry location, preferably indoors or within an electrical cabinet.
- Connect the AC input (110-260VAC) to your main power source.
- Connect the DC12V output to the access controller and lock as shown in the diagram.
- Adjust the time delay knob (0-15 seconds) on the power supply to set the desired unlock duration.
Electric Locks:
- Magnetic Locks (180KG): Mount the magnetic lock on the door frame and the armature plate on the door. Ensure proper alignment for maximum holding force.
- Electric Strike Locks: Install the strike lock into the door frame, replacing the standard strike plate. Ensure the door latch aligns correctly with the strike mechanism.
- Electric Drop Bolt Locks: Mount the drop bolt lock on the door frame or door edge, ensuring the bolt aligns with the strike hole when the door is closed.
Brackets (L, U, ZL):
- U Bracket (Kit6): Used for frameless glass doors with magnetic locks.
- L Bracket (Kit7): Used when the magnetic lock needs to be mounted on the door frame and the door is flat or the gap to the frame is small.
- ZL Bracket (Kit8): Used for magnetic locks on doors that open inwards.
Door Exit Button:
- Install the exit button on the inside of the door at a convenient height.
- Connect the exit button to the PUSH terminals on both the access controller and the power supply.
6. Operating Instructions
6.1. Unlock Methods

The A1 Keypad supports RFID card, password, and card+password unlock methods.
- RFID Card: Present a programmed RFID card to the card reading area on the keypad. The lock will disengage.
- Password: Enter your programmed password on the digital keypad, then press '#'. The lock will disengage.
- RFID Card + Password: Present your programmed RFID card, then enter your password and press '#'. This method provides enhanced security.
- Exit Button: Press the 'DOOR EXIT' button from the inside to momentarily unlock the door.
- Remote Control (if included): Press the unlock button on the remote control to disengage the lock.
6.2. Programming
The default programming password is 123456.
Entering Programming Mode:
- Press '*'.
- Enter the programming password (default: 123456).
- Press '#'. The work indicator light will change, indicating you are in programming mode.
Adding Users (RFID Card or Password):
- Enter Programming Mode.
- Press '1' to add a user.
- To add an RFID card: Present the new RFID card to the keypad. The keypad will beep to confirm.
- To add a password: Enter a 4-6 digit password, then press '#'. Re-enter the password and press '#' again to confirm.
- Repeat for additional users or press '*' to exit programming mode.
Deleting Users:
- Enter Programming Mode.
- Press '2' to delete a user.
- To delete by RFID card: Present the RFID card to be deleted.
- To delete by password: Enter the password to be deleted, then press '#'.
- Repeat for additional deletions or press '*' to exit programming mode.
Changing Programming Password:
- Enter Programming Mode.
- Press '3'.
- Enter the new 4-6 digit programming password, then press '#'.
- Re-enter the new password and press '#' again to confirm.
- Press '*' to exit programming mode.
6.3. Doorbell Function
The keypad supports a wired doorbell function. Press the doorbell button on the keypad to activate the connected doorbell.
7. Maintenance
- Cleaning: Wipe the keypad and other components with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
- Inspection: Periodically check all wiring connections for looseness or damage.
- Outdoor Protection: For keypads installed outdoors, regularly inspect any protective covers or sealants to ensure they remain intact and prevent water ingress.
8. Troubleshooting
- Lock remains open after installation: This often indicates a wiring issue, particularly with Fail Secure (NO) vs. Fail Safe (NC) lock types. Double-check your lock type and ensure it's connected to the correct terminals (NC or NO) on the power supply. You may need to reprogram the system.
- Keypad not responding / Red and Green lights on: This could indicate a programming issue or a fault. Try resetting the keypad to factory defaults (refer to programming instructions for reset procedure, if available, or contact support).
- Doorbell not working: Verify the doorbell wiring connections to the keypad and ensure the doorbell itself is functional and powered correctly (if it requires external power).
- Electromagnet gets warm: It is normal for electromagnets to generate some heat during continuous operation. Excessive heat, however, might indicate a problem.
- System not working after power outage: If your lock is Fail Safe (unlocked when power is off), it will open during a power outage. Consider installing an uninterruptible power supply (UPS) for continuous operation.
- RFID reader not working through plexiglass: RFID signals can be affected by materials. While some thin materials might work, thicker or metallic materials can block the signal. Test with your specific setup.
9. User Tips
- Outdoor Use: If installing the keypad outdoors, create a protective visor or cover to shield it from direct rain and snow, as it is not fully waterproof (IP65).
- Power Backup: For critical security applications, consider connecting the system to an uninterruptible power supply (UPS) to maintain functionality during power outages.
- Programming Assistance: If you encounter difficulties with programming, search for video tutorials online (e.g., on YouTube) for visual guidance. The default programming password is '123456'.
- Keyfob Quantity: It's advisable to order extra RFID keyfobs, as some users have reported issues with a small percentage of keyfobs failing over time.
- Intercom Integration: The system can often be integrated with an intercom system if the intercom provides a dry contact output for door release. Consult your intercom's manual for compatibility.
10. Warranty & Support
For warranty information, technical support, or service inquiries, please contact your original seller or the OBO HANDS Official Store directly. Provide your product model (A1 kit) and any relevant purchase details when seeking assistance.