ATORCH UD18L

Contents

ATORCH UD18L USB & DC Digital Tester User Manual

Model: UD18L

1. Introduction

The ATORCH UD18L is a versatile USB & DC Digital Tester designed for comprehensive monitoring and testing of various electronic devices. It can measure voltage, current, power, capacity, energy, temperature, and USB D+/D- voltage. With multi-interface support (USB-A, Type-C, DC5.5, Micro USB) and Bluetooth connectivity, it provides real-time data analysis via mobile app and PC software, making it an essential tool for evaluating power supplies, chargers, and batteries.

ATORCH UD18L Digital Tester with PC software and mobile app interface

Figure 1: ATORCH UD18L Digital Tester with PC software and mobile app interface

Video 1: ATORCH UD18L Product Demonstration

2. Key Features

  • Multi-Interface Support: Compatible with USB-A, Type-C, DC5.5, and Micro USB inputs/outputs.
  • High-Precision Measurement: 6-bit display accuracy for voltage, current, and power (up to 0.00001).
  • Bluetooth Connectivity: Wireless data transmission to iOS and Android apps for real-time monitoring and analysis.
  • Multi-Screen Display: Switch between various measurement interfaces to view current, voltage, power, timing, capacity, energy, and temperature data.
  • 360° Screen Rotation: Allows reading measurement data from any angle.
  • Programmable Protection: Set full power-off, timed charging, over-current protection (OCP), over-voltage protection (OVP), and low-voltage protection (LVP).
  • Bidirectional Current Design: Capable of testing both forward and reverse current flow.
  • Fast Charging Protocol Support: Compatible with QC and PD fast charging protocols.
  • External Temperature Sensor Support: Connect an optional external temperature sensor for diverse temperature measurements (sensor not included).

3. Specifications

3.1. Digital Tester Performance Parameters

Parameter Value
Voltage Measuring Range3.600V ~ 32.00V
Current Measuring Range0.000 ~ 5.100A
Capacity Cumulative Range0 ~ 99999mAh
Energy Cumulative Range0 ~ 999.99Wh
Power Metering Range000.00 ~ 163.00W
Temperature Measurement Range0 ~ 80°C
Timing Maximum Time999 hours 59 minutes 59 seconds
USB D+ Voltage Range0V ~ 2.99V
USB D- Voltage Range0V ~ 2.99V
Refresh Time> 500ms/time
Measurement RateApprox. 0.5 times/second
Self-Consumption Current≤ 0.025A
Working Temperature-10 ~ +60°C
Working Humidity10 ~ 80% (non-condensing)
Working Air Pressure80 ~ 106kPa
Product Size62mm × 62mm × 14mm

3.2. UD18L Adjustable Constant Current Load Parameters

Parameter Value
Input InterfaceUSB-A, Micro USB Female, Type-C Female
Discharge Tube ModelsIRFP260N (50A / 200V)
Adjust PotentiometerPrecision adjustable potentiometer
Cooling MethodIntelligent temperature control fan + whole aluminum heat sink
Input VoltageDC5 ~ 24.0V
Adjustable Current0.1 ~ 4.8A (Max current within 65W, P=UI)
Constant Current Precision±2%
Current Adjustment MethodMultiple resistance fine adjustment
Aging Wattage Rating45W (sustainable)
Limit Aging Power65W (short time within 3 minutes)
Fan Control ModeIntelligent temperature control (fan speed increases with temperature)
Highest Fan SpeedMAX12000 ± 10 RPM
Product Size77mm × 63mm × 45mm
Self-Consumption Current< 0.02A
Working Temperature-10 ~ +60°C
Working Humidity10 ~ 80% (non-condensing)
Working Air Pressure80 ~ 106kPa

Attention: Due to the current high voltage trigger board supporting PD3.1 28V voltage, do not use electronic loads exceeding 28V for testing when the electronic load switch is turned on! The USB tester can be used for 3.6-32V testing. The electronic load section has a maximum test capacity of 24V, 65W.

4. Setup

4.1. Initial Connection

  1. Plug the UD18L Tester into a compatible USB charger or power source. The Bluetooth indicator on the device will light up.
  2. Connect the device you wish to test (e.g., mobile phone, notebook, power bank) to the appropriate output port of the UD18L Tester.
UD18L connected to an electronic load for aging test

Figure 2: UD18L connected to an electronic load for aging test (65W/45W)

4.2. Mobile App Installation & Bluetooth Connection

  1. Download the App:
  2. Enable Bluetooth: Ensure Bluetooth is turned on on your mobile phone.
  3. Open E-test App: Launch the E-test application on your phone.
  4. Connect to Device: Click the Bluetooth icon in the upper left corner of the app interface. Select "JDY-19" or "UD18" from the list of available devices to connect.
  5. Connection Confirmation: The Bluetooth icon in the app will change from gray to blue, indicating a successful connection.

Important Warning: If you cannot find the Bluetooth model (JDY-19 or UD18) in the E-test app, ensure that the app's storage permissions and location information are enabled in your phone's settings.

UD18L Bluetooth Connection Method with mobile phone screenshots

Figure 3: UD18L Bluetooth Connection Method and App Permission Settings

5. Operation

5.1. Front-End Operation (Device Buttons)

After connecting the device and the display screen lights up:

  • Short Press 'M' Button: Switches between different measurement screens/interfaces.
  • Long Press 'OK' Button: Rotates the screen display by 360°, allowing for viewing from any angle.
  • Long Press 'M' Button (in main interface): Enters parameter setting mode. The value to be set will flicker. Use short presses of 'M' and 'OK' to adjust the value or clear capacity/energy/time data. The flickering stops automatically, and "OK" is displayed to confirm saving. You can also long-press 'M' to continue adjusting other parameters or long-press 'OK' to save and exit the setting mode.
Multi-screen measurement interface showing various data displays

Figure 4: Multi-screen measurement interface showing various data displays

UD18L screen rotating 360 degrees

Figure 5: UD18L screen rotating 360 degrees for flexible viewing

5.2. Back-End Operation (System Settings)

To access advanced system settings:

  1. Ensure the device is powered off.
  2. Press and hold any button on the device.
  3. While holding the button, power on the device. Release the button once the back-end display interface appears.
  4. Use short presses of 'M' and 'OK' to navigate and select the desired setting column.
  5. Long press 'M' to make the value in the selected column flicker.
  6. Use short presses of 'M' and 'OK' to adjust the value.
  7. The flickering will stop automatically, and "OK" will be displayed to confirm saving. Alternatively, long-press 'OK' to save and exit the current setting column.

5.3. Mobile App Interface Introduction

The mobile app provides a comprehensive interface for monitoring and controlling the UD18L tester wirelessly via Bluetooth.

Mobile APP interface introduction showing various data and controls

Figure 6: Mobile APP interface introduction

Mobile APP interface showing detailed measurement parameters

Figure 7: Mobile APP interface showing detailed measurement parameters

6. Calibration

6.1. Back-End Voltage and Current Calibration

To ensure accurate measurements, you can calibrate the voltage and current using the back-end settings:

  1. Enter the back-end display interface (refer to Section 5.2).
  2. Navigate to column 02 (Voltage/Current No-Load Reset). Long press 'M' to perform zero adjustment for voltage and current when the device is in an independent power supply state.
  3. Navigate to column 03 (Voltage Calibration). Connect a standard power supply adjusted to 10V to the measurement input end. The current measured voltage value will be displayed. Long press 'OK' to automatically correct the measurement and display the 10V standard voltage value. "OK" will be displayed to store the calibration value and exit voltage calibration.
  4. While still in column 03 (Current Calibration), connect a standard constant-current load meter adjusted to 2A to the measurement input. The current measured current value will be displayed. Long press 'OK' to automatically correct the measurement and display the 2A standard current value. "OK" will be displayed to store the calibration value and exit current calibration.
  5. To restore factory settings, navigate to column 09 (Default Settings) and long press 'OK'. The system will recall factory default values and calibration settings.
Precision analysis with calibration equipment showing voltage and current graphs

Figure 8: Precision analysis with calibration equipment

7. Testing Tips & Advanced Functions

7.1. Setting Full Charging and Power-Off Parameters

To protect your devices from overcharging, you can set a full charging power-off threshold:

  1. Observe and record the charging power value of your device when it reaches 100% charge.
  2. Add 1-3W to this observed value. This will be your continuous power value for the full charging power-off setting.
  3. In the device's settings (via front-end or back-end operation), set the power-off threshold to be less than this calculated wattage.
  4. When the system detects that the power value is below your set threshold and has been sustained for the configured virtual charging time, it will display a power-off icon and cut off the power output.

Tip: When the measured value reaches the set over-current, over-voltage, or low-voltage protection thresholds, the output will be disconnected, and a corresponding interface will be displayed.

Various detection scenarios and protection interfaces

Figure 9: Various detection scenarios and protection interfaces (FCOP, TC, Over-C, Over-V, Low-V)

7.2. Testing Mobile Power Supply (Power Bank) Capacity

To test the approximate capacity and energy of a power bank:

  1. Fully charge your power bank.
  2. Connect the UD18L tester to the power bank.
  3. Use the device buttons to clear the cumulative capacity and energy values to zero.
  4. Connect an electronic load or a mobile phone to the UD18L tester to begin discharging the power bank.
  5. Continue discharging until the power bank is fully depleted.
  6. Reconnect the UD18L tester to power (if it powered off). The accumulated capacity and energy values displayed will represent the approximate capacity and energy of the power bank.

Note: The UD18L has a power-off memory function, so the discharge process can be completed in one go or in multiple sessions. Due to internal cell voltage (e.g., 3.7V) being boosted to 5V or 9V, there are physical capacity differences and conversion losses. For a 5V output, the measured capacity value needs to be multiplied by approximately 1.35 to estimate the power bank's nominal capacity. This is an approximate value and not absolute.

UD18L testing various USB/PD power banks

Figure 10: UD18L testing various USB/PD power banks

7.3. Testing Charger Maximum Output Current and Quality

To evaluate a charger's maximum output current and overall quality:

  1. Connect the UD18L tester to the charger.
  2. Gradually increase the load (e.g., using an electronic load) until the voltage drops to the charger's nominal voltage. The current value displayed at this moment is the charger's maximum output current.
  3. Set the load to the charger's nominal current value and discharge for 2-6 hours (aging test).
  4. Quality Assessment:
    • If the current and voltage remain stable, and the charger's temperature stays below 50°C, it indicates that the charger's nominal current is accurate and meets charging speed requirements.
    • If the voltage drops significantly, the current value deviates greatly, the temperature becomes too high, the UD18L displays an alarm, or there is no output, these are signs of an inaccurate nominal current or poor quality charger.

Note: The charger's nominal current is its maximum output under full load, not necessarily the current supplied to a phone during charging. Charging currents for devices like phones fluctuate based on their state. The UD18L displays the actual current flowing, which may differ from the nominal value due to device-specific charging curves. Always refer to Ohm's Law (Voltage / Resistance = Current) for calculations.

Diagram showing test power methods for USB chargers and PD chargers

Figure 11: Test power methods for USB chargers and PD chargers

8. User Tips

  • Clarity is Key: While this manual aims for clarity, some advanced functions may require experimentation. Refer to the official PDF manual for further details.
  • Large Battery Testing: For testing very large capacity batteries (e.g., car batteries), the UD18L's amperage might be too low for quick results, and a full capacity test could take a very long time. It is primarily designed for smaller electronic device batteries and chargers.
  • Packaging: The device often comes securely packaged, sometimes in a tin box, which helps protect it during transit.

9. Troubleshooting

  • Device Not Powering On:
    • Ensure the UD18L is correctly plugged into a functional power source.
    • Check the power source itself to ensure it is providing power.
    • If using a USB port, try a different port or a dedicated USB charger.
  • Bluetooth Connection Issues:
    • Verify that Bluetooth is enabled on your mobile phone.
    • Make sure the E-test app has the necessary storage and location permissions enabled in your phone's settings.
    • Ensure the UD18L tester is powered on and its Bluetooth indicator is lit.
    • Try restarting both the UD18L tester and your mobile phone.
  • Inaccurate Readings:
    • Perform a calibration as described in Section 6.1.
    • Ensure all connections are secure and free from damage.
    • Avoid testing in extreme environmental conditions outside the specified operating temperature and humidity ranges.
  • Protection Functions Triggering Unexpectedly:
    • Review your set OCP, OVP, LVP, and full power-off thresholds. Adjust them if they are too sensitive for your testing scenario.
    • Ensure the connected load or power source is operating within expected parameters.

10. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Handling: Handle the device with care to avoid physical damage. Do not drop or expose it to excessive force.
  • Disassembly: Do not attempt to disassemble or repair the device yourself, as this will void the warranty and may cause damage or injury.

11. Warranty & Support

The ATORCH UD18L USB & DC Digital Tester comes with the following warranty:

  • 15-Day Exchange: If a performance fault occurs within 15 days of purchase, and the product and packaging are complete and unscratched (excluding human factors), a product of the same model can be exchanged.
  • 6-Month Repair: If a performance fault occurs within 6 months of purchase, paid repair services are available.

Warranty Exclusions:

  • Products beyond the warranty period.
  • Accessories are not covered by warranty.
  • Unauthorized disassembly by non-staff.
  • Failure to provide the warranty card.

A detailed user manual (PDF) is available for download from the seller's official media page: User manual (PDF).

12. Technical Support

For technical assistance or inquiries, please contact:

Distributor: Shenzhen Ous Technology Co., Ltd.
Phone: 0755-29550897

Manufacturer: Dongguan Kexin Electronic Technology Co., Ltd.
Address: No. 59 Jiufeng Road, Sancun Village, Qingxi Town, Dongguan City

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.