1. Introduction
This manual provides detailed instructions for the safe and effective use of your SZBJ VC92 LCD Digital Multimeter. Please read it thoroughly before operation and keep it for future reference.
1.1. Intended Use
The SZBJ VC92 Multimeter is designed for measuring and displaying electric quantities, including:
- AC and DC voltages up to 2500V Max.
- AC and DC currents up to 10A Max.
- Resistances from 10Ω to 200 MΩ.
- Capacitance up to 2000uF.
- Acoustic continuity checks.
- AC Live identification.
The device is intended for use in overvoltage categories CAT II (up to 1000V) and CAT III (up to 500V to ground potential), in accordance with EN 61010-1. It is powered by batteries only.
1.2. Safety Instructions
Failure to comply with these operating instructions may result in personal injury, material damage, or void the warranty. Always observe the following safety guidelines:
- General Safety: Do not operate the instrument with an open battery compartment or missing lid. Avoid damp rooms or unfavorable ambient conditions (excessive dampness, combustible gases, strong electrostatic fields, etc.).
- Voltage Precautions: Before measuring voltages, ensure the instrument is not set to a current range. The voltage between any socket and ground must not exceed 1000V (CAT II). Exercise extreme caution with voltages exceeding 25V AC or 35V DC, as these can be fatal.
- Instrument Inspection: Before each measurement, inspect the instrument and test leads for damage (cuts, cracks, pinches). Replace defective leads immediately.
- Handling: Do not touch connections directly or indirectly during measurements. Only touch within the tangible grip markings on the test prods.
- Environmental Conditions: Do not use during or immediately after a thunderstorm. Ensure hands, shoes, clothing, and the work area are dry.
- Accessories: Use only measuring lines and accessories that correspond to the multimeter's specifications.
- Malfunction: If you suspect the device can no longer be operated safely (e.g., visible damage, malfunction, exposure to heavy stress), disconnect it immediately.
- Temperature Acclimation: Do not switch on the instrument immediately after moving it from a cold to a warm environment. Allow it to reach room temperature to prevent condensation damage.
- Children: Keep packaging material and the instrument out of reach of children.
Safety Symbols
- ⚠: Important information or warning.
- ⚡: Warning of electric shock or impairment of electrical safety.
- ℹ: Special information and advice on operating.
- CE: Device is CE certified and meets European regulations.
- □□: Protection class II (double or reinforced insulation).
- CAT II: Overvoltage category II for measurements on electric and electronic devices connected to mains power supply.
- CAT III: Overvoltage category III for measuring building wiring installation.
- ⏚: Earth potential.
1.3. Product Description
The SZBJ VC92 is an analogue multimeter featuring a quality movement instrument and a scale with a mirror for accurate readings. It can be used in any operating position, supported by a back support bracket that also allows for a slightly slanted display. A compact rubber holster protects the device from impacts. Individual measuring functions and ranges are selected via a rotary switch. The multimeter is suitable for hobby or professional applications.
Key labeled components include:
- Rubber protective sleeve
- Backlight screen
- Disconnect indicator
- Power key
- Triode measurement function (HFE)
- DC current (A)
- AC current (A)
- Capacitance (F)
- mA, capacitance, temperature, hole
- 2000V voltage hole
- Data retention (DH)
- Resistance (Ω)
- Functional range knob
- DC voltage (V=)
- AC voltage (V~)
- V/Ω socket
- Public end socket (COM)
1.4. Scope of Delivery
Your package should contain:
- SZBJ VC92 Digital Multimeter with removable compact rubber holster
- One pair of safety measuring gold-coated Test Leads (red and black)
- Operating instructions (this manual)
2. Setup
2.1. Battery Installation
The multimeter requires two 1.5V AA batteries (not included) for operation. Follow these steps to install or replace batteries:
- Remove all measuring lines and turn off the multimeter.
- Loosen the housing screw on the back and carefully slide off the battery compartment lid.
- Insert new 1.5V AA batteries, observing the correct polarity as indicated in the compartment.
- Carefully close the housing again and tighten the screw.
2.2. Test Lead Preparation
On delivery, the measuring lines might be covered with protective sleeves. Before use, pull these sleeves off the safety plugs and test prods. After use, put them back on for transport protection.
2.3. Null Balance (Zero Adjustment)
Before measuring, always perform null balancing using the calibration screw (scale value 0V). Ensure there is no measuring signal on the measuring lines during this process. The scale display can be calibrated via the calibration screw to prevent faulty tests.
3. Operating Procedures
3.1. General Measurement Safety
- Do not exceed the permitted maximum input values.
- Always start measuring with the largest measuring range, then gradually switch down to achieve an exact result.
- The measuring ranges on the rotary switch correspond to the scale end value.
- Always turn off the device when not in use by setting the rotary switch to "OFF".
3.2. Rotary Switch
The individual measuring functions and ranges are selected via the rotary range switch. When the switch is set to "OFF", the device is powered off, and resistance and capacitance functions are inactive.
3.3. Measuring AC and DC Voltage
⚠ Do not exceed the permitted max. input values. This also applies when measuring superimposed DC/AC voltages.
- Select the desired measuring range (DCV or ACV) using the rotary switch.
- Connect the black measuring line to the COM jack and the red measuring line to the +V/mA/Ω input jack.
- Perform null balancing to set the needle at the zero position on the left side.
- For DCV testing, observe polarity (red = +, black = -). If polarity is incorrect, no value is displayed due to the built-in protective diode.
- For ACV testing, ensure the rotary switch is at the proper ACV range.
- Read the measured value on the "V" scale.
For DC2500V/AC2500V testing:
- Select the measuring range DC2500V or AC2500V using the rotary switch.
- Connect the black measuring line to the -COM jack and the red measuring line to the special +2500V input jack at the top right corner.
- Contact the test leads with the object being tested.
- Read the measured value on the "V" scale.
3.4. Measuring AC and DC Current
⚠ Do not exceed the permitted max. input values. Current measurement is only admissible in circuits up to 250V.
To measure direct currents up to 10A:
- Select the measuring range DC10A or AC10A using the rotary switch.
- Connect the black measuring line to the COM jack and the red measuring line to the special +10A input jack.
- Perform null balancing.
- For DC testing, observe polarity. For AC testing, ensure the range switch is at 10A.
- Read the measured value on the "A" scale.
To measure direct currents up to 250mA:
- Select the corresponding mA range using the rotary switch.
- Connect the black measuring line to the COM jack and the red measuring line to the +mA input jack.
- Perform null balancing.
- Observe polarity for DC testing.
3.5. Resistance Measurement
⚠ Ensure all circuit parts, switches, components, and test objects are currentless and discharged.
- Select the measuring range on the rotary switch Ω.
- Connect the black measuring line to the COM socket and the red measuring line to the +V/Ω input jack.
- This device does not require a common Zero OHM calibration adjustor; it maintains 0 Ohm automatically.
- Read the measured value on the "Ω" scale and multiply by the measuring range to get the result.
NOTE: If the needle is not at the right 0Ω line before testing, the inner battery must be replaced.
3.6. Acoustic Continuity Check
⚠ Ensure all circuit parts, switches, components, and test objects are currentless and discharged.
The continuity check provides a quick check of a line. A beep sounds if forward resistance is <200 Ohm.
- Select the measuring ♫)) range on the rotary switch.
- Connect the black measuring line to the COM jack and the red measuring line to the +VΩ input jack.
- Connect the two test probes to the test object.
- A beeper sounds when resistance is <50 Ohm, and the red LED flashes.
Note: If wrongly connected with voltage, quickly remove test leads to avoid damage. This tester can withstand <250V DC/AC rms for up to 5 seconds.
3.7. Capacitance Measurement
WARNING: DO NOT APPLY VOLTAGE TO MEASURING TERMINAL WHILE MAKING ANY CAPACITANCE MEASUREMENTS. BEFORE TESTING ANY CAPACITORS, DISCHARGE THE CAPACITOR COMPLETELY.
- Set the selector switch to the R X100(Cuf) range.
- Connect the BLACK test lead to the "-COM" jack and the RED test lead to the Red "+" jack.
- Connect the test leads to the capacitor to be measured (observe polarity).
- Watch the needle deflection to the right topside, and read the Red CuF scale on the Dial.
3.8. AC Live Check
This function identifies the AC Live polarity of wires or outlets.
- Set the rotary selector switch to the AC Live range.
- Connect one test probe to the Ω+V/Ω jack.
- Touch the test lead tip to the terminal of a wire or outlet.
- If the red LED lights and the buzzer sounds, the contacted wire is a Live line. Otherwise, it is a Zero line or Ground wire.
Note: The Red LED flashes once ACV > 50V, and the Buzzer sounds once ACV > 100V approximately.
3.9. Reading the Meter
The following table provides a reference for reading the meter pointer for various functions and ranges.
| Test | Range Position | Scale to Read | Multiplied |
|---|---|---|---|
| Resistance (Ω) | x1 | Ω | x1 |
| x10 | x10 | ||
| x100 | x100 | ||
| x1K | x1000 | ||
| x10K | x10000 | ||
| AC/DC Volt (V) | 0.1V | A. V. 10 | x0.01 |
| 2.5V | 250 | x0.01 | |
| 10V | 10 | x1 | |
| 50V | 50 | x1 | |
| 250V | 250 | x1 | |
| 1000V | 10 | x100 | |
| 2500V | 250 | x10 | |
| AC/DC Current (A) | DC 50µA | A. V. 50 | x1 |
| 2.5mA | 250 | x0.01 | |
| 25mA | 250 | x0.1 | |
| 250mA | 250 | x1 | |
| DC/AC 10A | 10 | x1 | |
| Capacitance CuF | 2,000 uF | C1:1 - 2,000 | x1 |
4. Maintenance
4.1. General Maintenance
To ensure accuracy, the multimeter should be calibrated once a year. Regularly check the technical safety of the instrument and measuring lines for damage. ⚠ Never operate the measuring device when it is open!
4.2. Cleaning
⚠ Live components may be exposed if covers are opened or parts are removed. Before cleaning or repairing, disconnect all lines and turn off the device.
Do not use agents containing carbon, benzene, alcohol, or similar substances, as they can corrode the surface and are detrimental to health. Avoid sharp-edged tools or metal brushes. Use a clean, lint-free, antistatic, and dry cleaning cloth to clean the device, display, and measuring lines.
4.3. Battery Replacement
Replace batteries when null balancing in the resistance measuring range can no longer be performed. The device uses two 1.5V AA batteries.
- Remove all measuring lines and turn off the multimeter.
- Loosen the housing screw on the back and carefully slide off the battery lid cover.
- Remove the old batteries and insert new 1.5V AA batteries, observing polarity.
- Carefully close the housing again.
⚠ Never operate the measuring device when it is open. Do not leave flat batteries in the device, as they can corrode and release harmful chemicals. Remove batteries if the device will not be used for an extended period. Use protective gloves if handling leaked or damaged batteries.
4.4. Fuse Replacement
⚠ Always adhere to safety instructions when replacing the fuse. Use only a fuse of the specified type and rated current (0.5A/250V quick-acting Φ5x20 mm). Using unsuitable or repaired fuses is inadmissible and can cause fire.
If measurements can no longer be made via the "V/mA" socket, the internal fuse must be replaced.
- Remove all measuring lines and turn off the multimeter.
- Pull off the soft holster from the ABS housing.
- Loosen the housing screw on the back and carefully slide off the battery compartment lid.
- Push the plastic peg between the two battery compartments forward until the case is unlocked. Carefully remove the rear housing.
- Replace the inside microfuse with a new fuse of the same type: 0.5A/250V quick-acting Φ5x20 mm.
- Close the device in reverse order and carefully screw the battery compartment lid back on, then recover the holster.
4.5. Battery Disposal
The end user is legally obliged to return all used batteries and rechargeable batteries. Disposal in household waste is prohibited!
4.6. Resistance Null Adjustment
This meter typically maintains a 0 Ohm position automatically when measuring resistance. However, if the pointer does not return to 0 Ohm when the test leads are shorted, you can perform null adjustment:
- Open the back cover of the meter (remove soft holster, unscrew, remove battery cover).
- Use a small screwdriver to gently rotate the Ω potentiometer (as shown in the diagram in section 2.3) until the pointer returns to the 0 Ohm position.
- Reassemble the meter.
5. Troubleshooting
If you encounter problems, refer to the table below for possible causes and solutions. Always observe safety instructions first!
| Error | Possible Cause |
|---|---|
| The multimeter does not work. | Are the 1.5V batteries low on power? Check the state of the battery and the 0.5A fuse. |
| No measurements possible via V/mA socket. | Is the fuse defective? Check the 0.5A fuse (fuse replacement). |
| No measurements possible via 10A socket. | Is the rotary selector placed correctly or are the test leads connected correctly? |
| No change in measured values. | Have you selected the right measuring sockets? Is the measuring mode correct (AC/DC)? |
| Faulty measuring results are displayed. | Has null balancing of the display been performed? Or are the batteries properly located? |
6. Specifications
For detailed technical specifications, please refer to the table below. This product is guaranteed for a one-year warranty.
| Parameter | Value/Range | Accuracy | Remarks |
|---|---|---|---|
| Over-voltage Category | CAT II 1000V, CAT III 500V | ||
| Standard Environment | 23°C ±3°C, <75% RH, 50/60Hz | ||
| Operating Temperature | 0°C to 40°C (32°F to 104°F) | ||
| Storage Temperature | -10°C to 50°C (14°F to 122°F) | ||
| Operating Humidity | <90% RH | ||
| Storage Humidity | <80% RH | ||
| Operating Altitude | Max. 2,000 m | ||
| Dimensions (WxDxH) | 160 x 104 x 44 mm (including Holster) | ||
| Weight | Approx. 380g (including batteries & Holster) | ||
| Accessories | CAT II 1000V/20A Test Leads, Quick-acting glass-tube Fuse 0.5A/250V x1pc | ||
| DC Voltage (DC V) | 0-0.1-2.5-10-50-250V-1000V-2500V | ±3% of FSD (0.1-250V), ±4% of FSD (1000V/2500V) | Input Impedance: 20KΩ/V (9KΩ/V > 1000V). Overload Protection: Max. 2500V AC/DC. Ranges 0.1V/0.5/10/50V: Max. 250V. |
| AC Voltage (AC V) | 0-10-50-250V-1000V-2500V | ±4% of FSD | Input Impedance: 9 KΩ/V. Bandwidth: 20 ~ 20K Hz. Overload Protection: Max. 2500Vrms AC/DC. Ranges 10/50V: Max. 250V. |
| DC Current (DC A) | 0-0.05-0.25-2.5-25-250mA, 10A | ±3% of FSD (0.05-250mA), ±4% of FSD (10A) | Drop Voltage: 250 mV. Overload protected by Fuse 0.5A at mA ranges. 10A range is not fused. |
| AC Current (AC A) | 0-10A | ±4% of FSD | Drop Voltage: 250 mV. Bandwidth: 20 ~ 20K Hz. Not fused. |
| Resistance (Ω) | X1: 2~20KΩ, X10: 20~200KΩ, X100: 200~2MΩ, X1K: 2M~20MΩ, X10K: 20M~200MΩ | ±3% of ARC (Scale Length) | Overload protected by Oxide Varactor & Fuse. Input Voltage limit: Min.50V, Max. 250Vrms AC/DC for 5 seconds. |
| AC Live | One LED Red Light flashing >AC 50V and Buzzer sounding >AC100V. | ||
| Capacitance | 1~2,000uF(CuF) | Approximate Value | Use the R×100 range via test leads. |
| Continuity Check | <50 Ohm | Beeper sounding & LED | Overload protected by Fuse & Oxide Varactor (<250V AC/DC for 5s). |
NOTE#1: The extra indication error will occur as per the waveforms of measured ACV/ACA other than the sine wave. Its readings of rms value may be lower or higher than the actual root-mean-square value.
NOTE#2: For 10A range, the big current loaded max. 1min. and pause 5 min. at least before next testing.
7. Warranty and Support
This product is provided with a one-year quality guarantee from the manufacturer. The manufacturer assumes no liability for any malfunction or damage resulting from improper use, disregard of instructions, or violation of relevant laws and regulations.
For further assistance, please refer to the full user manual PDF available at: SZBJ VC92 User Manual (PDF)
8. User Tips