Contents

SZBJ BM803A+ Digital Clamp Meter User Manual

Comprehensive instructions for safe and effective use of your BM803A+ Clamp Multimeter.

1. Introduction

Thank you for purchasing the SZBJ BM803A+ Professional Digital Clamp Meter. This manual provides important information for the safe and correct operation of the device. Please read it thoroughly before use and keep it for future reference.

1.1 Intended Use

The BM803A+ Digital Clamp Meter is designed for measuring and displaying electrical quantities. Its primary functions include:

  • Measuring AC/DC voltage up to 1000V (CAT II) or 500V (CAT III) to ground potential, and up to 2500V Max.
  • Measuring AC/DC current up to 1000A.
  • Measuring resistance from 10 Ω to 200 MΩ without zero adjustment.
  • Checking capacitance up to 2000µF.
  • Acoustic continuity check.
  • AC Live identification.
  • Temperature measurement.
  • Frequency and Duty Cycle measurement.

The device is intended for use by professionals, in factories, schools, and for amateur and home use. It operates on batteries and must not be used with an open battery compartment. Avoid operation in damp or unfavorable ambient conditions, or in the presence of combustible gases, vapors, or strong electromagnetic fields.

Any use other than described above may damage the product and poses risks such as short-circuit, fire, or electric shock. Do not modify any part of the product.

2. Safety Instructions

Failure to comply with these operating instructions may result in personal injury or material damage. The manufacturer assumes no liability for damages resulting from improper use or disregard of safety instructions.

The following symbols are used in this manual and on the device:

  • ⚠: An exclamation mark indicates important information that must be observed.
  • ⚡: A lightning symbol warns of danger of electric shock or impairment of electrical safety.
  • ⓘ: Indicates special information and advice on operating.
  • CE: Device is CE certified and meets European regulations.
  • ☐: Protection class II (double or reinforced insulation).
  • ⊙: Earth potential.

2.1 General Safety Guidelines

  • Always ensure the measuring instrument is not set to current range before measuring voltages.
  • The voltage between any socket and ground must not exceed 1000V in overvoltage category II.
  • Exercise extreme caution when dealing with voltages exceeding 25 V AC or 35 V DC, as these can cause fatal electric shock.
  • Before each measurement, inspect the instrument and its measuring leads for damage (cuts, cracks, pinches). Replace defective leads immediately.
  • Do not touch connections directly during measurements; only hold test prods by their tangible grip markings.
  • Avoid using the multimeter during or immediately after a thunderstorm.
  • Ensure hands, shoes, clothing, the floor, the instrument, and measuring leads are dry.
  • Do not operate in environments with combustible gases, vapors, dust, strong magnetic/electromagnetic fields, or near transmitting aerials/HF generators.
  • Use only measuring leads and accessories that correspond to the multimeter's specifications and have double or reinforced insulation.
  • If the device appears damaged or malfunctions, disconnect it immediately and prevent unintentional operation.
  • Allow the device to reach room temperature before use if moved from a cold to a warm environment to prevent condensation damage.
  • Keep packaging material away from children.

3. Product Overview

The SZBJ BM803A+ is a handheld digital clamp multimeter designed for high reliability, accuracy, and portability. It features a large LCD display with a maximum count of 3999, True RMS measurement, auto-ranging, data hold, diode test, and continuity test. The super big jaw can be opened 52mm, and the clamp head closes without a gap to reduce magnetic induction error.

3.1 Components

Front view of the BM803A+ Digital Clamp Meter
Figure 3.1: Front view of the BM803A+ Digital Clamp Meter, showing the display, rotary switch, and input jacks.
Dimensions of the BM803A+ Digital Clamp Meter
Figure 3.2: Dimensions of the BM803A+ Digital Clamp Meter (approx. 249mm length, 89mm width, 38mm depth).

The multimeter is equipped with a quality movement instrument and a compact rubber holster for protection. The individual measuring functions and ranges are selected via a rotary switch.

3.2 Package Contents (SET A example)

Contents of SET A package for BM803A+ Clamp Meter
Figure 3.3: Example contents of a SET A package, including the clamp meter, battery, test leads, temperature probe, user manual, carrying bag, and product certificate.

The standard package typically includes:

  • BM803A+ Digital Clamp Multimeter
  • Storage bag
  • Test leads (red and black, gold-coated)
  • Temperature probe
  • User manual (this document, also available as PDF: User Manual PDF)
  • 9V 6F22 battery (may not be included, check packaging)

4. Specifications

This section details the technical specifications of the BM803A+ Digital Clamp Meter.

4.1 General Specifications

  • Over-voltage category: CAT II 1000V to ground potential.
  • Standard Environment: 23°C ± 3°C, less than 75% RH at 50/60Hz.
  • Operating Temperature: 0°C to 40°C (32°F to 104°F).
  • Storage Temperature: -10°C to 50°C (14°F to 122°F).
  • Operating Humidity: Less than 90% RH.
  • Storage Humidity: Less than 80% RH.
  • Operating Altitude: Max. 2,000 m.
  • Size: 160(W) x 104(D) x 44(H) mm (including Holster).
  • Weight: Approx. 380g (including batteries & Holster).
  • Display Count: 3999.
  • Jaw Opening: 52mm.
  • Power Supply: 1 x 9V 6F22 battery (not included).
  • Features: True RMS, Auto Range, Data Hold, Diode Test, Continuity Test, NCV Test, Backlight.

4.2 Range Specifications & Tolerance List

Function Range Accuracy Remarks
DC Voltage (V) 0.1V, 2.5V, 10V, 50V, 250V, 1000V, 2500V ±3% of FSD (0.1V/1000V/2500V ranges ±4%) Input Impedance: 20KΩ/V (9KΩ/V > 1000V). Overload Protection: Max. 2500V AC/DC.
AC Voltage (V) 10V, 50V, 250V, 1000V, 2500V ±4% of FSD. Bandwidth: 20 ~ 20K Hz. Input Impedance: 9 KΩ/V. Overload Protection: Max. 2500Vrms AC/DC.
DC Current (A) 0.05mA, 2.5mA, 25mA, 250mA, 10A ±3% of FSD (10A range ±4%) Drop Voltage: 250 mV. Overload protected by 0.5A fuse at mA ranges, 10A no fuse.
AC Current (A) 0.2A, 10A ±4% of FSD. Bandwidth: 20 ~ 20K Hz. Drop Voltage: 250 mV. No fuse protected.
Resistance (Ω) X1 (2Ω ~ 20KΩ), X10 (20Ω ~ 200KΩ), X100 (200Ω ~ 2MΩ), X1K (2KΩ ~ 20MΩ), X10K (20KΩ ~ 200MΩ) ±3% of ARC (Scale Length) Overload protected by Oxide Varactor & Fuse. Input Voltage limit: Min.50V, Max. 250Vrms AC/DC for 5 seconds.
Capacitance 1µF ~ 2000µF Approximate Value Use the R×100 range via test leads.
Continuity Check < 50 Ohm Beeper sounding & LED Overload protected by Fuse & Oxide Varactor (<250V AC/DC for 5s).
AC Live AC Live One LED Red Light flashing >AC 50V and Buzzer sounding >AC100V

NOTE#1: The extra indication error will occur as per the waveforms of measured ACV/ACA other than the sine wave. Its readings of rms value may be lower or higher than the actual root-mean-square value.

NOTE#2: For 10A range, the big current loaded max. 1min. and pause 5 min. at least before next testing.

5. Operating Procedures

Before operating the device, ensure batteries are correctly installed as described in the "Cleaning and Maintenance" section.

5.1 Rotary Switch

The rotary switch selects individual measuring functions and ranges. Setting the switch to "OFF" turns off the device and disables resistance and capacitance testing. Always turn off the device when not in use.

5.2 General Measuring Guidelines

  • ⚠ Do not exceed maximum input values. Avoid touching circuits with voltages over 25V AC RMS or 35V DC.
  • Always inspect test leads for damage before use. Replace any damaged leads immediately.
  • Remove test prods from the test object before changing the measuring range.
  • Always begin measurements with the largest measuring range, then gradually switch down for accuracy.
  • For reading, select the corresponding scale value on the display.

5.3 Null Balance

Before measuring, perform null balancing using the calibration screw (scale value 0V). Ensure no measuring signal is present on the measuring lines.

5.4 Measuring AC and DC Voltage

Hand holding BM803A+ with test leads connected for voltage measurement
Figure 5.1: Proper grip and test lead connection for voltage measurement.
  1. Select the desired DCV or ACV measuring range using the rotary switch.
  2. Connect the black measuring lead to the COM jack and the red measuring lead to the +V/mA/Ω input jack.
  3. Perform null balancing to set the needle to the zero position on the left side.
  4. For DCV testing, observe correct polarity (red = +, black = -). Connect test prods to the object. If polarity is incorrect, no value is displayed. Stop and remeasure with correct polarity.
  5. For ACV testing, ensure the rotary switch is at the proper ACV range.
  6. Read the measured value on the "V" scale.
  7. For DC2500V/AC2500V testing, connect the black lead to the -COM jack and the red lead to the special +2500V input jack at the top right corner.
  8. After measurement, turn the rotary switch to "OFF".

5.5 Measuring AC and DC Current

Clamp meter measuring current on a single wire
Figure 5.2: Example of using the clamp meter to measure current on a single wire.
Clamp meter measuring current on multiple wires
Figure 5.3: Incorrect current measurement: Do not clamp multiple wires simultaneously for accurate readings.

⚠ Do not exceed permitted max. input values. Current measurement is only admissible in circuits up to 250V.

5.5.1 Measuring Direct Currents up to 10A:

  1. Select the DC10A or AC10A range using the rotary switch.
  2. Connect the black measuring lead to the COM jack and the red measuring lead to the special +10A input jack.
  3. Perform null balancing to set the needle at the left zero scale position.
  4. For DC testing, observe correct polarity (red = +, black = -). Connect test prods in series with the object.
  5. For AC testing, ensure the range switch is at 10A.
  6. Read the measured value on the "A" scale.
  7. After measuring, turn the rotary switch to "OFF".

5.5.2 Measuring Direct Currents up to 250mA:

  1. Select the corresponding mA range using the rotary switch.
  2. Connect the black measuring lead to the COM jack and the red measuring lead to the +mA input jack.
  3. Perform null balancing to set the needle at the left zero scale position.
  4. Observe correct polarity (red = +, black = -) and connect test probes in series with the object.
  5. Read the measured value on the "A" scale.
  6. After measuring, turn the rotary switch to "OFF".

5.6 Resistance Measurement

⚠ Ensure all circuit parts, switches, components, and test objects are currentless and discharged before measuring resistance.

  1. Select the Ω measuring range on the rotary switch.
  2. Connect the black measuring lead to the COM socket and the red measuring lead to the +VΩ input jack.
  3. This device does not require Zero OHM calibration adjustment.
  4. Read the measured value on the "Ω" scale. Multiply the displayed value by the measuring range to get the result (e.g., 100Ω (display) x 10kΩ (range) = 1MΩ).
  5. After measuring, turn the rotary switch to "OFF".

NOTE: If the needle is not kept at the right 0Ω line before testing, the inner battery must be replaced.

5.7 Acoustic Continuity Check

⚠ Ensure all circuit parts, switches, components, and test objects are currentless and discharged.

  1. Select the continuity (♫) range on the rotary switch.
  2. Connect the black measuring lead to the COM jack and the red measuring lead to the +VΩ input jack.
  3. Connect the two test probes to the object.
  4. A beeper sounds and the red LED flashes if resistance is <50 Ohm.
  5. After measuring, turn the rotary switch to "OFF".

Note: If wrongly connected with voltage, quickly remove test leads. This tester can withstand <250V DC/AC rms for a maximum of 5 seconds.

5.8 Capacitance Measurement

WARNING: DO NOT APPLY VOLTAGE TO MEASURING TERMINAL WHILE MAKING ANY CAPACITANCE MEASUREMENTS. BEFORE TESTING ANY CAPACITORS, DISCHARGE THE CAPACITOR COMPLETELY.

  1. Set the selector switch to the R X100(Cuf) range.
  2. Connect the BLACK test lead to the "-COM" jack and the RED test lead to the Red "+" jack.
  3. Connect the test leads to the capacitor to be measured (observe polarity).
  4. Watch the needle deflection to the right topside, and read the Red CuF scale on the Dial.
  5. After measurement, set the selector switch to "OFF" position.

5.9 AC Live Check (NCV Test)

This function identifies the AC Live polarity of wires or outlets without contact.

  1. Set the rotary selector switch to the AC Live range.
  2. Connect one test probe to the "+V/Ω" jack.
  3. Touch the tip of this test lead to the terminal of a wire or outlet.
  4. If the Red LED lights up and the buzzer sounds, it indicates a Live line. Otherwise, it is a Zero line or Ground wire.

Note: The Red LED flashes once ACV > 50V, and the Buzzer sounds once ACV > 100V approximately.

6. Cleaning and Maintenance

6.1 General

To maintain accuracy, the multimeter should be calibrated once a year. Always check the technical safety of the instrument and measuring lines regularly. Never operate the device when it is open.

6.2 Cleaning

⚠ Live components may be exposed if covers are opened. Disconnect all lines and turn off the device before cleaning or repairing.

Do not use carbon, benzene, alcohol, or similar substances for cleaning, as they can corrode the surface and are harmful. Use a clean, lint-free, antistatic, and dry cleaning cloth for the device, display, and measuring lines.

6.3 Inserting/Replacing Batteries

The device requires 1.5V AA batteries (not included in some packages). Replace batteries when null balancing in the resistance range can no longer be performed.

  1. Remove all measuring lines and turn off the multimeter.
  2. Loosen the housing screw on the back and carefully slide off the battery compartment lid.
  3. Remove the old battery and insert new 1.5V AA batteries, observing polarity.
  4. Carefully close the housing again.

⚠ Never operate the measuring device when it is open.

⚠ Do not leave flat batteries in the device. Remove batteries if the device is not used for a long period to prevent leaking. Leaked or damaged batteries can burn skin; use protective gloves.

Make sure batteries are not short-circuited. Do not throw batteries into fire. Alkaline batteries are recommended for their power and longevity.

6.4 Replacing the Fuse

⚠ Always adhere to safety instructions when replacing the fuse! Use only a fuse of the specified type (0.5A/250V quick-acting Φ5 x 20 mm). Using unsuitable fuses or bypassing the fuse holder is dangerous.

If measurements can no longer be made via the "V/mA" socket, the internal fuse needs replacement.

  1. Remove all measuring lines and turn off the multimeter.
  2. Pull off the soft holster from the ABS housing.
  3. Loosen the housing screw on the back and carefully slide off the battery compartment lid.
  4. Push the plastic peg between the two battery compartments forward until the case is unlocked. Carefully remove the rear housing.
  5. Replace the inside microfuse with a new fuse of the same type: 0.5A/250V quick-acting Φ5 x 20 mm.
  6. Close the device in reverse order and carefully screw the battery compartment lid back on, then recover the holster.

6.5 Disposal of Used Batteries/Rechargeable Batteries

Used batteries and rechargeable batteries must be returned to designated collection points. Disposal in household waste is prohibited.

7. Troubleshooting

⚠ Always observe safety instructions first!

Error Possible Cause
The multimeter does not work. Are the 1.5V batteries low power? Or check the state of the battery and the 0.5A fuse.
No measurements possible via V/mA socket. Is the fuse defective? Check the 0.5A fuse (fuse replacement).
No measurements possible via 10A socket. Is the rotary selector placed correctly or are the test leads connected right?
No change in measured values. Have you selected the right measuring sockets? Is the measuring mode correct (AC/DC)?
Faulty measuring results are displayed. Has null balancing of the display been performed? Or are the batteries properly located?

8. User Tips

  • Always double-check your range selection before taking a measurement, especially when dealing with unknown voltages or currents, to prevent damage to the meter or yourself.
  • For current measurements using the clamp, ensure only one conductor is inside the jaw for accurate readings. Clamping multiple conductors will measure the net current, which may be zero if currents are balanced.
  • When measuring resistance or continuity, always ensure the circuit is de-energized and capacitors are discharged.
  • Keep the test leads and meter clean and dry to ensure reliable performance and safety.

9. Warranty and Support

This product is provided with a one-year quality guarantee by the manufacturer. The manufacturer is not responsible for any malfunctions or issues arising from user's failure to follow the instructions in this manual, violation of common sense, or relevant laws and regulations.

For further assistance or to view the full user manual in PDF format, please refer to the official document: SZBJ BM803A+ User Manual (PDF).

10. Signs and Symbols

Understanding the symbols used on the device and in this manual is crucial for safe and correct operation.

Symbol Description
∞ Overload, measuring range exceeded
♫ Symbol for the acoustic continuity checker
OFF Switch position OFF
COM/N/⊙ Reference potential, - for DC / N for AC / Earth potential
AC Alternating quantity for voltage and current
DC Constant quantity for voltage and current
mV Millivolt
V Volt (unit of electric potential)
A Ampere (unit of electric current)
mA Milliampere
µA Microampere
Ω Ohm (unit of electric resistance)
KΩ Kiloohm
MΩ Megaohm
CµF Micro Farad for Capacitance
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.