This manual provides instructions for the installation, operation, maintenance, and troubleshooting of the TECNR S&A Temperature Controller Display. This device is designed for use with industrial water chillers such as CW3000, CW5000, and CW5200. Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage.

2. Setup

2.1. Unpacking

Carefully remove the temperature controller from its packaging. Inspect the unit for any signs of damage during transit. If any damage is found, contact your supplier immediately.

2.2. Mounting

The controller is designed for panel mounting. Ensure there is adequate space for ventilation around the unit and access to the wiring terminals.

2.3. Wiring

WARNING: Before performing any wiring, ensure that the power supply to the chiller and the controller is completely disconnected to prevent electric shock or damage to the equipment.

IMPORTANT: Verify the correct voltage for your specific controller model. T-503A models require DC24V, while T-506A/B models require 220VAC.

2.3.1. Wiring for T-503A (T-503, T-504)

Refer to the wiring diagram below for the T-503A model. Ensure all connections are secure and correctly matched.

Detailed wiring diagram for S&A T-503A Temperature Controller
Figure 1: T-503A Wiring Diagram (Close-up)

T-503A Wiring Connections (DC24V):

  • 1: Compressor
  • 2: Common terminal
  • 3: Solenoid valve
  • 6/7: Power Supply DC24V (6 is positive, 7 is negative)
  • 9: Water temperature probe
  • 11: Room temperature probe
Rear view of S&A T-503A Temperature Controller with wiring diagram
Figure 2: T-503A Rear View with Wiring Diagram

2.3.2. Wiring for T-506A (T-506) and T-506B (T-506H)

Refer to the wiring diagram below for the T-506A/T-506B models. These models operate on 220VAC. Ensure all connections are secure and correctly matched.

Rear view of S&A T-506A/T-506B Temperature Controller with wiring diagram
Figure 3: T-506A/T-506B Rear View with Wiring Diagram

T-506A/B Wiring Connections (220VAC):

  • 1: Flow sensor
  • 2: Water temperature input
  • 3: External input
  • 4: Common (for inputs)
  • 5: L (Live for 220VAC power)
  • 6: N (Neutral for 220VAC power)
  • 7: Compressor (Normally Open)
  • 8: Compressor (Common)
  • 9: Solenoid Valve (Normally Open)
  • 10: Solenoid Valve (Common)
  • 11: Heater (Normally Open)
  • 12: Heater (Common)
  • 13: Alarm (Normally Closed)
  • 14: Alarm (Common)
  • 15: Alarm (Normally Open)

3. Operating Instructions

3.1. Basic Controls

The controllers feature a digital display and several buttons for operation:

  • RST (Reset) Button: Typically used to reset alarms or return to the main display.
  • SET Button: Used to enter parameter setting mode or confirm selections.
  • Up/Down Arrow Buttons: Used to navigate menus or adjust parameter values. (T-506B models may have additional arrow buttons for navigation).
Front view of S&A T-503A Temperature Controller
Figure 4: T-503A Front Panel
Front view of S&A T-506B Temperature Controller
Figure 5: T-506B Front Panel

3.2. Display Information

The digital display typically shows the current (actual) temperature and the set temperature. Indicators for compressor status, alarm status, or other operational modes may also be present depending on the model.

3.3. Setting the Temperature

To adjust the desired temperature (set point):

  1. Press the SET button. The display may show the current set point or flash.
  2. Use the Up/Down Arrow buttons to adjust the temperature to your desired value.
  3. Press the SET button again to confirm the new setting and exit the setting mode.

For advanced parameter settings (e.g., differential, calibration), refer to the specific model's detailed operational guide or contact technical support.

4. Maintenance

4.1. Cleaning

Keep the controller's display and casing clean. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the plastic and electronic components.

4.2. Inspection

Periodically inspect the wiring connections to ensure they are secure and free from corrosion. Ensure that the controller is not exposed to excessive dust, moisture, or extreme temperatures.

5. Troubleshooting

If you encounter issues with your temperature controller, try the following basic troubleshooting steps:

  • No Power/Display Off:
    • Check the power supply connection to the controller.
    • Ensure the power source is active and providing the correct voltage (DC24V for T-503A, 220VAC for T-506A/B).
    • Check for any blown fuses in the power line if applicable.
  • Incorrect Temperature Readings:
    • Verify that the temperature probes are correctly connected to the controller.
    • Ensure the probes are properly immersed or placed in the environment they are meant to measure.
    • Check for any damage to the probe cables.
  • Controller Not Responding:
    • Try power cycling the unit (turn off power, wait 30 seconds, then turn back on).
    • Ensure no buttons are stuck.
  • Chiller Not Responding to Controller:
    • Check the wiring connections between the controller's output terminals (compressor, solenoid valve, heater) and the chiller's corresponding inputs.
    • Verify the set temperature is appropriate for the chiller's operation.

If the problem persists after performing these steps, contact your supplier for further assistance.

6. Specifications

FeatureSpecification
BrandTECNR
Models CoveredT-503A (T-503, T-504), T-506A (T-506), T-506B (T-506H)
Power Supply (T-503A)DC24V
Power Supply (T-506A/B)220VAC
CertificationCE
OriginMainland China
Package Length20 cm
Package Width10 cm
Package Height10 cm
Package Weight0.38 kg

7. User Tips

  • Voltage Compatibility: Always double-check the voltage requirements of your specific chiller and ensure it matches the voltage of the temperature controller you are installing (DC24V for T-503A, 220VAC for T-506A/B). Incorrect voltage can cause severe damage.
  • Model Interchangeability: The T-503 and T-504 models are generally universal and can be used interchangeably.
  • Chiller Compatibility: These controllers are designed to work with various industrial water chillers, including CW3000, CW5000, and CW5200.

8. Warranty and Support

For any warranty claims, technical support, or further inquiries regarding your TECNR S&A Temperature Controller, please contact your original seller or distributor. Provide your product model and purchase details for efficient service.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.