1. Introduction
The Retekess TM101 is a wireless call button designed to function as an intelligent responder in knowledge and debate contests. It features wireless signal transmission and provides visual feedback through colored LED lights indicating different states: standby, start, success, and foul. This manual provides instructions for the setup, operation, and maintenance of the TM101 button as part of a compatible intelligent responder system.
Note: The TM101 buttons are designed to work with a compatible host system (e.g., Retekess TM102 Quiz Answer Game Buzzer System) and are not compatible with TM102 buttons. They are not standalone mobile accessories.

2. Safety Warnings and Guidelines
Please read these important safety instructions before using the Retekess TM101 Wireless Call Button to ensure safe operation and compliance with regulations.
RF Energy Exposure and Product Safety
This device uses radio frequency (RF) energy for communication. All Retekess radios are designed, manufactured, and tested to meet government-established RF exposure levels. Improper use of RF energy can cause biological damage. Users should be aware of RF energy exposure and follow simple procedures to control it.
General Guidelines:
- Do NOT operate the radio without a proper antenna attached.
- Do NOT transmit for more than 50% of total radio use time to avoid exceeding RF exposure compliance requirements.
- Turn off the radio in areas sensitive to electromagnetic radiation (e.g., hospitals, aircraft, blasting sites).
- The device complies with RF specifications when used at 5mm from your body. Third-party belt-clips, holsters, and similar accessories should not contain metallic components.
Unauthorized Modification and Adjustment
Changes or modifications not expressly approved by the party responsible for compliance may void the user's authority to operate this radio. Transmitter adjustments should only be made by technically qualified personnel.
FCC and CE Requirements
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference and must accept any interference received. This equipment has been tested and found to comply with the limits for a Class B digital device.
The device also complies with essential requirements and other relevant provisions of RED Directive 2014/53/EU, ROHS Directive 2011/65/EU, and WEEE Directive 2012/19/EU.
Avoid Choking Hazard
WARNING: Small Parts. Not for children under 3 years.
Battery Safety
- When conductive materials (jewelry, keys) touch exposed battery terminals, it can cause a short circuit and become hot, leading to burns. Handle batteries with care.
- Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to local regulations.
- Remove batteries if the device will not be used for a long period.
3. Package Contents
The package for the Retekess TM101 Wireless Call Button typically includes:
- 1 x Retekess TM101 Wireless Call Button

4. Specifications
| Feature | Specification |
|---|---|
| Model Number | TM101 |
| Brand Name | retekess |
| Origin | Mainland China |
| Certification | CE, FCC |
| Power Supply | 2 x AA battery (not included) |
| Battery Included | No |
| Material | ABS |
| Size | 100*100*30mm |
| Weight | 84g |
| Wireless Transmission | Yes |
| Automatic Sleep Function | Yes (no operation) |
| LED Light Tips | Standby, Start, Foul, Success |
| Package Length | 11 cm |
| Package Width | 11 cm |
| Package Height | 4 cm |
| Package Weight | 0.1 kg |
5. Setup
5.1 Battery Installation
- Locate the battery compartment on the bottom of the TM101 button.
- Slide the battery cover open.
- Insert 2 x AA batteries (not included) into the compartment, ensuring correct polarity (+/-).
- Close the battery cover securely.

5.2 Powering On/Off
To power on the TM101 button, slide the ON/OFF switch located on the bottom of the device to the 'ON' position.
To power off, slide the switch to the 'OFF' position. It is recommended to turn off the button and remove batteries if not in use for a long time to extend battery life.
5.3 Pairing with Host System (Learning Number F2)
The TM101 button needs to be paired with a compatible host unit or remote control to function correctly. This process assigns a unique number to each button.
- On the host unit/remote control, short press the [Function Key] to enter the system menu.
- Navigate to [F2] and press [Function Key] again to enter the setting mode. The default flashing display will show "01".
- Use the [Up/Down] buttons on the host unit/remote control to set the desired number for the responder (range 1-32).
- After adjusting to the desired number, press and hold the TM101 responder button for about 2 seconds until it flashes blue. This indicates it's attempting to match the host code.
- Upon successful pairing, the responder button will flash red.
- After setting is completed, press the [Reset button] on the host unit/remote control to exit the setting mode.

6. Operation
The TM101 Wireless Call Button interacts with a host system, which is configured using its own buttons (Up, Down, Function, Reset) and a remote control (Start, Time, Reset). The following settings are typically configured on the host unit.
6.1 Display Button Description (Host Unit/Remote Control)
- ▲ Up button
- ▼ Down button
- Function key/shift key
- Reset button / exit button
6.2 Remote Control Button Description
- Start
- Time
- Reset
6.3 Answer Time Setting (F1)
This setting defines the duration for answering questions.
- On the host unit/remote control, press [Function Key] to enter the system menu.
- Navigate to [F1] and press [Function Key] again to enter the setting mode. The current answering time will be displayed, flashing.
- Use the [Up/Down] buttons to set the answer time (unit: seconds, range: 1-999).
- Short press [Reset button] to exit the setting mode once completed.
- After a successful answer, press the [Timer] button on the remote control. The display will show the specified answer time and start counting down.
6.4 Local ID Setting (F3)
This setting configures the local ID of the system.
- On the host unit/remote control, short press [Function Key] to enter the system menu.
- Navigate to [F3] and press [Function Key] again to enter the setting mode. The default flashing display will show "01".
- Use the [Up/Down] buttons to set the number (range: 1-15).
- Press [Reset Key] after setting to exit the setting mode.
Note: You need to relearn the responder numbers after changing the Local ID. Do not change the local ID without special circumstances.
6.5 Answer Mode Setting (F4)
The system supports different answer modes:
6.5.1 Normal Mode (Mode 1)
In this mode, after pressing the [Start] button, players can directly answer. There is no 3-second countdown, no voice reminder, and no foul judgment.
- On the host unit/remote control, short press [Function Key] to enter the system menu.
- Navigate to [F4] and press [Function Key] again to enter the setting mode. The current answer mode will be displayed, flashing.
- Set the number to "1" by pressing [Up/Down].
- Press [Reset] to exit the setting mode after setting.
6.5.2 Voice Mode (Mode 2)
In this mode, pressing [Start] initiates a 3-second countdown with a voice reminder. If an answer is given within these 3 seconds, it's considered a foul and requires a restart.
- On the host unit/remote control, short press [Function Key] to enter the system menu.
- Navigate to [F4] and press [Function Key] again to enter the setting mode. The current answer mode will be displayed, flashing.
- Set the number to "2" by pressing [Up/Down].
- Press [Reset] to exit the setting mode after setting.
6.5.3 Elimination Mode (Mode 3)
In this mode, pressing [Start] initiates a 3-second countdown with a voice reminder. If an answer is given within these 3 seconds, it's considered a foul, but other players can continue to answer until someone successfully responds, everyone fouls, or the time is up. The winner's button lights green, the fouler's button lights red, and losers' buttons do not light up.
- On the host unit/remote control, short press [Function Key] to enter the system menu.
- Navigate to [F4] and press [Function Key] again to enter the setting mode. The current answer mode will be displayed, flashing.
- Set the number to "3" by pressing [Up/Down].
- Press [Reset] to exit the setting mode after setting.
6.6 Effective Answer Time Setting (F5)
This setting determines the effective time for a player's answer after the 3-second countdown initiated by the [Start Key]. If the player's answer exceeds this time, it is regarded as a waiver.
- On the host unit/remote control, short press [Function Key] to enter the system menu.
- Navigate to [F5] and press [Function Key] again to enter the setting mode. The current answering time will be displayed, flashing.
- Use the [Up/Down] buttons to set the time (range: 0-99).
- Press the [Reset button] to exit the setting mode after setting.
6.7 Communication Channel Setting (F6)
This setting configures the communication channel between the responder button and the host. If the responder is not sensitive, try changing the host channel.
- On the host unit/remote control, press [Function Key] to enter the system menu.
- Navigate to [F6] and press [Function Key] again to enter the setting mode. The current channel will be displayed, blinking.
- Use the [Up/Down] buttons to set the time (range: 0-15).
- Press the [Reset button] to exit the setting mode after setting.
After changing the host channel for 10 seconds, the responder will flash three lights and automatically match the host channel. If the match is successful, the responder light will go out and enter the standby state. If the responder does not match the host, it will automatically enter low-power mode. You may need to manually press the responder to wake up and re-match the channel.




7. Maintenance
7.1 Cleaning
Wipe the exterior of the TM101 button with a soft, dry cloth. Do not use abrasive cleaners or solvents.
7.2 Battery Care
If the device will not be used for an extended period, remove the AA batteries to prevent leakage and corrosion, which can damage the device.
8. Troubleshooting
8.1 Button Not Responding / Insensitive
- Check Batteries: Ensure that the 2 x AA batteries are correctly installed and have sufficient charge. Replace if necessary.
- Check Power Switch: Verify that the ON/OFF switch on the bottom of the TM101 button is in the 'ON' position.
- Re-pair Button: If the button becomes unresponsive, try re-pairing it with the host system by following the "Learning Number F2" steps in Section 5.3.
- Change Host Channel: If the responder is not sensitive, try changing the host system's communication channel (F6 setting in Section 6.7). After changing the host channel, the responder will attempt to re-match. If it enters low-power mode, manually press the responder to wake it up and re-match.
8.2 Incorrect LED Indication
- Verify Answer Mode: Ensure the host system's answer mode (F4 setting in Section 6.5) is configured as desired (Normal, Voice, or Elimination mode).
- Check Answer Time Settings: Review the Answer Time (F1) and Effective Answer Time (F5) settings on the host system to ensure they match the game rules.
9. User Tips
- System Compatibility: The TM101 button is designed to work as part of a larger intelligent responder system, such as the Retekess TM102 Quiz Answer Game Buzzer System. It is not a standalone device for mobile phones or other general-purpose applications.
- Battery Life: To maximize battery life, always turn off the button using the back switch when not in use. For long-term storage, remove the batteries.
- Numbering: When setting up multiple buttons, ensure each TM101 is assigned a unique number (1-32) through the host system's pairing process (Learning Number F2).
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact Retekess Official Store or refer to the product's official website. Keep your purchase receipt as proof of purchase.
Manufacturer: Henan Eshow Electronic Commerce Co., Ltd.
Address: 7/F, Sanjiang Building, No.170 Nanyang Road, Huiji District, Zhengzhou, Henan, China
EU Importer: Germany Retevis Technology GmbH
Address: Uetzenacker 29, 38176 Wendeburg