OBO HANDS T11+T22

Contents

OBO Hands RFID Access Control Keypad User Manual

Models: T11 / T22

1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of your OBO Hands RFID Access Control Keypad. This device is a secure and effective access control solution, supporting up to 1000 users with various identification methods. It is suitable for both home and office security systems.

Two OBO Hands RFID Access Control Keypads, one with a numeric keypad (T11) and one with a touch-sensitive keypad (T22).

Figure 1: OBO Hands RFID Access Control Keypads (T11 and T22 models)

2. Product Specifications

Feature Specification
Model Number T11+T22
Brand Name OBO HANDS
Origin Mainland China
Certification NONE
Smart home platform NONE
Effective Cards 1000
Password Capacity 1000
Card Type EM
Reading Distance 0~ 5cm
Working Voltage 12VDC+10%
Working Temperature 0℃~60℃
Relative Humidity 20%-80%
Dimension 120X22X78mm (L/H/W)
Weight 110g
Dimensions of the T11 access control keypad: 120mm length, 22mm height, 78mm width.

Figure 2: T11 Keypad Dimensions

Dimensions of the T22 access control keypad: 120mm length, 22mm height, 78mm width.

Figure 3: T22 Keypad Dimensions

3. Package Contents

The package contents vary based on the model selected:

  • Model: T11
    • 1x T11 access control keypad
    • 1x User manual
  • Model: T11 with Keyfobs
    • 1x T11 access control keypad
    • 10x RFID keyfobs
    • 1x User manual
  • Model: T22
    • 1x T22 access control keypad
    • 1x User manual
  • Model: T22 with Keyfobs
    • 1x T22 access control keypad
    • 10x RFID keyfobs
    • 1x User manual

4. Product Overview

Familiarize yourself with the components of your access control keypad:

Detailed view of the T11 keypad and its internal components, labeling the work indicator, card area, power cable socket, digital buttons, high quality relay, speaker, and door bell button.

Figure 4: T11 Keypad Component Analysis

  • Work Indicator: LED light indicating operational status.
  • Card Area: Designated area for presenting RFID cards.
  • Storage Chip: Internal component for storing user data.
  • Power Cable Socket: Connection point for power supply.
  • Digital Button: Numeric keypad for password entry.
  • High Quality Relay: Internal component for controlling door lock.
  • Speaker: Provides audible feedback for operations.
  • Door Bell Button: Activates an external doorbell (if connected).
Detailed view of the T22 keypad and its internal components, labeling the work indicator, card area, power cable socket, digital buttons, speaker, and door bell button.

Figure 5: T22 Keypad Component Analysis

  • Work Indicator: LED light indicating operational status.
  • Card Area: Designated area for presenting RFID cards.
  • Storage Chip: Internal component for storing user data.
  • Power Cable Socket: Connection point for power supply.
  • Digital Button: Touch-sensitive keypad for password entry.
  • Speaker: Provides audible feedback for operations.
  • Door Bell Button: Activates an external doorbell (if connected).

Both models feature a fast central processor and precision programming chip for sensitive and stable system operation.

5. Installation and Wiring

Important Note: The power supply, electric locks, and exit switch button are not included in the package and must be purchased separately. Ensure all connections are secure and correctly wired before applying power.

5.1 Wiring with Electric Strike Lock (NC Type)

Wiring diagram showing connections between a power supply, an access controller, an electric strike lock (NC type), and an exit button. The power supply connects to +12V and GND on the controller. The electric strike lock connects to NO and COM. The exit button connects to PUSH and GND. The access controller has connections for +12V, GND, BELL+, BELL-, LOCK+, LOCK-, OPEN, and GND.

Figure 6: Wiring Diagram for Electric Strike Lock (NC Type)

Follow the diagram above for connecting the access controller with an Electric Strike Lock (Normally Closed type), a power supply, and an exit button. Ensure:

  • The Power Supply is connected to the +12V and GND terminals of the Access Controller.
  • The Electric Strike Lock (NC Type) is connected to the NO (Normally Open) and COM (Common) terminals of the Access Controller.
  • The Exit Button is connected to the PUSH and GND terminals of the Access Controller.

5.2 Wiring with Magnetic Lock

Wiring diagram showing connections between a power supply, an access controller, a magnetic lock, and an exit button. The power supply connects to +12V and GND on the controller. The magnetic lock connects to NC and COM. The exit button connects to PUSH and GND. The access controller has connections for +12V, GND, BELL+, BELL-, LOCK+, LOCK-, OPEN, and GND.

Figure 7: Wiring Diagram for Magnetic Lock

Follow the diagram above for connecting the access controller with a Magnetic Lock, a power supply, and an exit button. Ensure:

  • The Power Supply is connected to the +12V and GND terminals of the Access Controller.
  • The Magnetic Lock is connected to the NC (Normally Closed) and COM (Common) terminals of the Access Controller.
  • The Exit Button is connected to the PUSH and GND terminals of the Access Controller.

6. Operation

The access control keypad supports three methods for unlocking the door:

Image illustrating three unlocking methods: using an RFID card, entering a PIN on the keypad, and combining both an RFID card and a PIN.

Figure 8: Unlocking Methods

  1. Password: Enter your pre-programmed PIN on the digital keypad.
  2. RFID Cards: Present a registered EM ID Key Tag to the card area.
  3. Password + RFID Cards: For enhanced security, use a combination of your RFID card and PIN.

The device supports a user capacity of 1000 cards and 1000 passwords. Refer to the included user manual for detailed instructions on programming user cards and passwords.

7. Maintenance

Your access control keypad is constructed from high-quality ABS flame-retardant material, offering fire prevention and high-temperature resistance. It also features surface protection against water.

Two access control keypads on a wet surface, demonstrating their surface waterproof feature.

Figure 9: Surface Waterproof Feature

  • Cleaning: Use a soft, dry cloth to clean the surface. Avoid abrasive cleaners or solvents.
  • Environmental Conditions: While the surface is waterproof, for long-term durability, it is recommended not to install this product outdoors where it is directly exposed to rain or extreme weather conditions.
  • Internal Components: The device features a fast central processor and precision programming chip for sensitive and stable operation. Do not attempt to open the casing unless you are a qualified technician.

8. Troubleshooting

If you encounter issues with your access control keypad, consider the following common troubleshooting steps:

  • No Power:
    • Check all power connections to ensure they are secure.
    • Verify the power supply is functioning correctly and providing the specified 12VDC.
  • Card Not Reading:
    • Ensure the RFID card is an EM type (125KHz).
    • Present the card within 0-5cm of the card area.
    • Verify the card is properly registered in the system.
  • PIN Not Working:
    • Ensure the correct PIN is being entered.
    • Check if the PIN is properly programmed for the user.
    • For T22 models, ensure touch input is registered correctly.
  • Door Not Unlocking:
    • Confirm the access controller is receiving power and the work indicator is active.
    • Check the wiring to the electric lock or magnetic lock as per the installation diagrams (Figures 6 and 7).
    • Ensure the lock itself is functional.
  • Door Bell Not Ringing:
    • Verify the doorbell is correctly wired to the BELL+ and BELL- terminals.
    • Ensure the doorbell unit is functional.

If problems persist, consult the detailed programming instructions in the included user manual or contact customer support.

9. User Tips

  • Regularly Test: Periodically test your access control system with all registered cards and PINs to ensure proper functionality.
  • Backup User Data: If possible, keep a record of all registered user IDs and PINs in a secure location for easy reference.
  • Consider a Cover: Although surface waterproof, installing a protective cover or placing the unit under an overhang can further extend its lifespan, especially in areas with heavy precipitation.

10. Warranty and Support

This product comes with a ONE YEAR warranty. If there is a problem with the product, it can be returned only if it is in perfect condition and with a reasonable reason. All packages are carefully checked before shipping. If there is a problem with the product you receive, compensation will be provided according to the situation of the defective product.

We provide 15 days or more protection time after order completion. If your item has any warranty issue, please contact us for a satisfying solution. The buyer should bear the shipping costs for return.

If you have any questions or require further assistance, please send a message via Trade Manager. All messages will be answered within 24 hours from Monday to Saturday.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.