1. Introduction

The GEYA SUL181h is a reliable Din Rail Analog Mechanical Timer designed for precise 24-hour programming. Driven by a quartz motor, it offers strong interference suppression and low power consumption, making it suitable for a wide range of applications.

This timer is commonly used in controlling neon lights, water heaters, street lamps, stair lamps, breeding equipment, garden irrigation systems, motors, advertising boxes, and various automatic control and office spaces.

It features a built-in battery for shutdown compensation, providing up to 150 hours of working reserve time, ensuring your programming is maintained even during power outages.

GEYA SUL181h Din Rail Analog Mechanical Timer front view

Figure 1: Front view of the GEYA SUL181h Timer.

2. Setup Instructions

2.1 Dimensions

Before installation, ensure the dimensions of the timer fit your intended mounting space.

Dimension diagram for GEYA SUL181h Timer

Figure 2: Dimensions of the SUL181h Timer (Unit: mm).

2.2 Mounting

The GEYA SUL181h timer is designed for DIN rail mounting. Ensure the DIN rail is securely installed before attaching the timer.

2.3 Wiring Connection

WARNING: Electrical equipment should only be installed and assembled by qualified electricians.

Connect the timer according to the following diagram. Ensure all connections are secure and comply with local electrical codes.

Connection Diagram for GEYA SUL181h Timer

Figure 3: Connection Diagram for SUL181h Timer. Connect Live (L) and Neutral (N) to terminals 1 and 2 respectively. Connect the load to terminals 3 and 4.

For detailed programming connections, refer to the 24h Program section.

3. Operating Instructions

3.1 Setting the 24-Hour Program

The timer allows for programming over a 24-hour cycle with a minimum setting unit of 30 minutes. You can set up to 48 ON/OFF times per day.

  1. Rotate the dial to set the current time.
  2. Push the segments on the outer ring of the dial inwards for the desired ON periods, and leave them outwards for OFF periods. Each segment represents 30 minutes.
  3. Ensure the manual override switch is set to 'auto' for automatic operation.
24h Program setting instructions for GEYA SUL181h Timer

Figure 4: Illustration of 24-hour program setting and example wiring for a lamp.

3.2 Manual Control ON/OFF (Override Control)

To manually override the programmed settings:

  1. Turn the control axis in the direction of the arrow by one notch.
  2. The manual control is automatically canceled by the next counteracting command of the automatic program sequence.

3.3 Permanent ON/OFF

To set a permanent ON or OFF state:

  1. Set the hand lever to 'Perm' for permanent control.
  2. Turning the control axis in the direction of the arrow allows for adjustment of the required permanent ON or OFF state.
  3. To return to automatic control, turn the hand lever to 'Auto'. The permanent control is terminated.
  4. Immediate corrections can be made using the manual control (override control).
Manual and Permanent ON/OFF control instructions

Figure 5: Manual and Permanent ON/OFF control mechanisms.

4. Maintenance

The GEYA SUL181h timer is designed for long-term, reliable operation with minimal maintenance. To ensure optimal performance:

  • Keep the timer clean and free from dust and debris.
  • Avoid exposing the device to extreme temperatures or humidity outside its specified operating range (-10°C to +55°C, relative humidity < 85%).
  • Do not attempt to open or repair the device yourself. Refer to qualified personnel for any servicing needs.
  • The internal battery recharges when the unit is connected to mains power. Ensure regular power supply to maintain the 150-hour power reserve.

5. Troubleshooting

If you experience issues with your GEYA SUL181h timer, consider the following:

  • Timer not switching: Check the power supply connections. Ensure the manual override switch is set to 'auto' if automatic operation is desired. Verify that the program segments are correctly set for ON/OFF times.
  • Incorrect timing: Ensure the current time is correctly set on the dial. The timer has an accuracy of less than 2 seconds per day at 25°C.
  • Loss of program after power outage: The internal battery provides a power reserve of 150 hours after 24 hours of recharging. If the power outage exceeds this duration or the battery is not sufficiently charged, the program may be lost. Ensure the timer is connected to power for at least 24 hours to fully charge the reserve battery.
  • Load not responding: Check the wiring to the load (terminals 3 and 4). Ensure the load itself is functioning correctly. Verify that the contact capacity of the timer (16A) is not exceeded by the connected load.

For persistent issues, contact GEYA customer support or a qualified electrician.

6. Specifications

Feature Specification
Model NumberSUL181h
Product NameSUL181-24hour Programm Timer Switch Mechanical
Brand NameGEYA
TheoryMechanical
TypeMini
UseTimer Switch
FunctionTime Control Switch, Automatic Cycle
OriginMainland China
CertificationCE
Battery IncludedNo
High-concerned chemicalNone
Operating Voltage / Rated VoltageAC 100-240V (Wide Range) 50/60Hz
Rated Frequency50/60Hz
Power Consumption2.5VA
Rated Current / Contact Capacity16A (AC 220V 16A)
Contact Resistance< 50MΩ
Insulation Resistance> 100MΩ
Operating Temperature-10°C to +55°C
Accuracy< 2S/day at 25°C
Lamp Load1000W Resistive Load: 16A/250VAC (cos=1)
Inductive Load3A/250VAC (cos=0.6)
Squirrel cage motor load1/2HP 230VAC
Tungsten lamp load900W 230VAC
Working Reserve Time150 hours after recharging 24 hours
Full Timing Range24h
Storage Battery150h (referring to reserve time)
Minimum Setting Unit30 Minutes
Setup Times48 times (30 Minutes/time)
Installing ModeDIN rail mounting
Size90mm × 54mm × 65mm

7. User Tips

  • Application Versatility: The SUL181h timer is robust and suitable for various applications, including controlling swimming pool filtering pumps. Its mechanical design offers reliability for consistent operation.
  • Power Reserve: To ensure the internal battery maintains its 150-hour power reserve for program retention during power outages, keep the timer connected to the main power supply for at least 24 hours after initial installation or prolonged disconnection.
  • Clear Programming: When setting your ON/OFF times, clearly distinguish between pushed-in (ON) and pulled-out (OFF) segments. Double-check your settings to avoid unintended operation.

8. Warranty and Support

GEYA products are manufactured to high standards and are certified according to various international standards including CE. For any technical assistance, warranty claims, or support, please contact your local GEYA distributor or visit the official GEYA website.

For more detailed information, you may refer to the official user manual PDF: GEYA SUL181h User Manual (PDF).

Video 1: GEYA Company Introduction. This video provides an overview of GEYA's manufacturing processes and commitment to quality.

© 2024 GEYA. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.