Introduction
The PEAKMETER PM8908C is a pen-style non-contact AC voltage detector designed for safe and efficient electrical testing. It can detect AC voltage within a range of 12V to 1000V, offering sound and light alarms, a built-in flashlight, and automatic power-off for convenience and safety. This manual provides essential information for the proper use and maintenance of your device.

Safety Information
Always adhere to local safety regulations and guidelines when working with electrical systems. This device is designed to enhance safety, but it does not replace proper electrical safety practices.
- Do not use the device if it appears damaged or is not operating correctly.
- Ensure the battery compartment is securely closed before use.
- Always test on a known live circuit before testing an unknown circuit to confirm the detector is functioning properly.
- The detector indicates the presence of AC voltage; it does not measure the exact voltage level.
- This device is rated CAT.III 1000V.
Package Contents
Upon opening the package, please verify that all items are present and undamaged:
- PEAKMETER PM8908C Non-contact AC Voltage Detector
- User Manual (this document)
Note: Batteries are NOT included and must be purchased separately. The device requires 2 x 1.5V AAA batteries.
Setup
1. Battery Installation
- Twist and pull off the battery cap at the rear of the device.
- Insert two (2) 1.5V AAA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
- Replace the battery cap and twist to secure it.


Operating Instructions
1. Power On/Off
- Press the power button (marked with ①) to turn the device on. The LED indicator will light up.
- The device will automatically power off after a period of inactivity to conserve battery life.
2. Non-Contact AC Voltage Detection (NCV)
The PM8908C uses non-contact technology to detect the presence of AC voltage without direct contact with live conductors.
- Turn on the device.
- Bring the probe tip of the detector close to the wire, outlet, or electrical component you wish to test.
- If AC voltage is detected, the device will emit an audible alarm and the LED indicator will flash. The intensity of the alarm and flashing may vary with voltage strength and proximity.

3. NCV Sensitivity Adjustment
The device features automatic selection of three sensitivity modes: high, medium, and low. This allows for detection across its full voltage range (12V-1000V AC) and helps pinpoint voltage sources more accurately.
- High Sensitivity: Detects lower voltages or voltage from a greater distance.
- Medium Sensitivity: Standard detection for general use.
- Low Sensitivity: Detects higher voltages or requires closer proximity, useful for distinguishing between adjacent wires.
The NCV sensitivity indication is provided by 3 kinds of frequency sound and LED alarms.
4. Live or Neutral Wire Detection
The detector can differentiate between live and neutral wires. When detecting a live wire, the device will provide a distinct sound and LED alarm compared to a neutral wire.
5. Flashlight Function
The built-in white LED flashlight can be activated to illuminate dimly lit work areas. Refer to the device's buttons for flashlight control (typically a dedicated button or a long press of the power button).

Maintenance
1. Cleaning
Wipe the device with a dry, clean cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the device.
2. Battery Replacement
When the low battery indication appears, replace the batteries promptly to ensure accurate readings and proper operation. Follow the battery installation steps in the "Setup" section.
3. Storage
Store the device in a cool, dry place away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.
Troubleshooting
- Device does not power on: Check if batteries are installed correctly and have sufficient charge. Replace batteries if necessary.
- No voltage detection:
- Ensure the device is powered on.
- Verify the batteries are not depleted (check for low battery indication).
- Test on a known live circuit to confirm functionality.
- Ensure the probe tip is close enough to the conductor.
- False positives/negatives: Environmental factors or strong electromagnetic fields can sometimes affect readings. Try re-testing in a different location or adjusting sensitivity if available.
Specifications
| Feature | Specification / Accuracy |
|---|---|
| AC Voltage Range | 12V ~ 1000V AC |
| Frequency | 50Hz ~ 60Hz |
| Alarm Mode | Sound and Light |
| Flashlight | White LED |
| Auto Power Off | Yes |
| Probe Shape | Prolate |
| Low Battery Indication | Yes |
| Live or Neutral Detection | Sound and LED alarmed |
| NCV Sensitivity | Automatic selection of 3 sensitivity modes (high, medium, low) |
| NCV Sensitivity Indication | 3 kinds of frequency sound and LED alarmed |
| Power Supply | 2 x 1.5V AAA batteries |
| Weight | Approx. 45g |
| Dimensions | 156 x 20 x 20mm |
| Safety Rating | EN61010-1, -2-030, EN61010-2-030, EN61326-1, CAT.III 1000V |
| Certification | RoHS |
| DIY Supplies | Electrical |
| Display Type | Analog Only |

User Tips
- Always perform a quick test on a known live circuit (e.g., a wall outlet) before using the detector on an unknown circuit to ensure it's working correctly.
- When detecting voltage, move the tip slowly along the wire or surface to ensure accurate detection, especially when trying to pinpoint the exact location of a live wire.
- The built-in flashlight is useful in dark environments, but remember to turn it off when not needed to save battery.
- Keep the device clean and free from dust and debris to maintain optimal performance.
Warranty and Support
For any questions, technical support, or warranty claims, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.