1. Introduction
This manual provides comprehensive instructions for the safe and efficient installation, operation, and maintenance of the GEYA GYHC Modular Contactor. Designed for household and similar applications, this contactor is suitable for controlling various electrical loads.
Please read this manual thoroughly before installation and operation to ensure proper usage and to prevent potential hazards.

Figure 1: GEYA GYHC-25M Modular Contactor
2. Safety Information
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel.
- Always disconnect power before installing or servicing the contactor.
- Ensure all wiring complies with local and national electrical codes.
- Do not use the contactor to break short-circuit currents. Appropriate short-circuit protection devices (e.g., circuit breakers) must be installed upstream.
- Verify that the voltage and current ratings of the contactor match the application requirements.
- Avoid touching live parts.
- Ensure proper grounding where required.
3. Product Overview
The GEYA GYHC Modular Contactor is designed for reliable switching of AC loads in residential and light commercial settings. Key features include:
- Space Optimization: 70% less than traditional contactors.
- Energy Saving: Up to 75% more efficient than traditional contactors (e.g., 2.7 VA vs 9.6 VA).
- Super-Quiet Operation: Less than 15dB, suitable for noise-sensitive environments.
- Long Lifespan: Features silver alloy contacts and an optimized electromagnetic system for stability and reliability.
- Modular Design: Compact size for easy integration into control lighting boxes with small circuit breakers.
- Manual Control: Equipped with a manual override switch for flexible operation.

Figure 2: Front view of the Contactor

Figure 3: Side view with dimensions
Video 1: GEYA GYHC Modular Contactor Product Overview and Manual Operation
4. Specifications
General Specifications
| Attribute | Value |
|---|---|
| Brand Name | GEYA |
| Model Number | GYHC Modular Contactor |
| Electricity Type | AC |
| Main Circuit Rating Current | Other (e.g., 16A, 20A, 25A, 32A, 40A, 63A) |
| Main Circuit Rating Voltage | Other (e.g., 220V/230V, 400V) |
| Number of Pole | 1, 2, 3, 4 |
| Phase | Other (Single-phase, Three-phase depending on poles) |
| Certification | CE |
| Origin | Mainland China |
| Customization | Yes |
| High-concerned chemical | None |
Rated Current, Control Voltage, and Holding Power
| Type | Rated Current (In) AC-7a | Rated Current (In) AC-7b | Control Voltage (VAC)(50 Hz) | Consumption (Holding) | Consumption (Inrush) | Maximum Power |
|---|---|---|---|---|---|---|
| 2P | 16A | 6A | 12 | 3.8VA | 15VA | 1.3W |
| 24 | 3.8VA | 15VA | 1.3W | |||
| 20A | 7A | 110 | 3.8VA | 15VA | 1.3W | |
| 220...240 | 2.7VA | 9.2VA | 1.2W | |||
| 25A | 8.5A | 12 | 3.8VA | 15VA | 1.3W | |
| 24 | 3.8VA | 15VA | 1.3W | |||
| 32A | 12A | 110 | 3.8VA | 15VA | 1.3W | |
| 220...240 | 2.7VA | 9.2VA | 1.2W | |||
| 40A | 15A | 110 | 4.6VA | 34VA | 1.6W | |
| 220...240 | 4.6VA | 34VA | 1.6W | |||
| 63A | 20A | 110 | 4.6VA | 34VA | 1.6W | |
| 220...240 | 4.6VA | 34VA | 1.6W | |||
| 4P | 16A | 6A | 24 | 4.6VA | 34VA | 1.6W |
| 110 | 4.6VA | 34VA | 1.6W | |||
| 20A | 7A | 220...240 | 4.6VA | 34VA | 1.6W | |
| 24 | 4.6VA | 34VA | 1.6W | |||
| 25A | 8.5A | 110 | 4.6VA | 34VA | 1.6W | |
| 220...240 | 4.6VA | 34VA | 1.6W | |||
| 32A | 15A | 24 | 6.5VA | 53VA | 2.1W | |
| 110 | 6.5VA | 53VA | 2.1W | |||
| 40A | 15A | 220...240 | 6.5VA | 53VA | 2.1W | |
| 24 | 6.5VA | 53VA | 2.1W | |||
| 63A | 20A | 110 | 6.5VA | 53VA | 2.1W | |
| 220...240 | 6.5VA | 53VA | 2.1W |
Contact Configurations
| Number of Poles | Breadth (mm) | Rated Current In (A) | Rated Control Voltage Us (V) | Contact Configuration |
|---|---|---|---|---|
| 1P | 18 | 16A/20A/25A | AC24V AC110V AC230V | 1NO, 1NC |
| 2P | 18 | 16A/20A/25A | AC24V AC110V AC230V | 2NO, 2NC, 1NO1NC |
| 3P | 36 | 32A/40A/63A | AC24V AC110V AC230V | 3NO, 3NC |
| 4P | 54 | 32A/40A/63A | AC24V AC110V AC230V | 4NO, 4NC, 2NO2NC, 3NO1NC |
Note: NO = Normally Open, NC = Normally Closed.
5. Installation and Setup
5.1 Normal Working and Installation Conditions
- Ambient Air Temperature: Not higher than +60°C and not lower than -5°C. When installed in a power distribution box, thermal insulation parts must be assembled on both sides to facilitate heat dissipation.
- Altitude: Not exceeding 2000m.
- Atmospheric Conditions: The relative humidity of the air at the installation site shall not exceed 50% when the maximum temperature is +40°C; Higher relative humidity is allowed at lower temperatures (e.g., 90% at +20°C). Special measures should be taken for occasional condensation due to temperature changes.
- Pollution Level: Level 2.
- Installation Category: Level II.
- Shock Vibration: There shall be no significant shock and vibration at the installation position.
- Installation Mode: TH35-7.5 profile steel mounting rail is used for installation.
- Installation Conditions: The installation position shall be vertical, and the inclination in each direction shall not exceed ±5°.
- Degree of Protection: IP20.
- Action Conditions: Pull-in voltage under operating conditions (85%~110%) Us; Release voltage is (20%~75%) Us.
5.2 Mounting on DIN Rail
The GEYA GYHC Modular Contactor is designed for easy mounting on a standard TH35-7.5 DIN rail. Ensure the rail is securely fastened within the electrical enclosure.

Figure 4: DIN Rail Mounting Mechanism
5.3 Accessories Installation (Thermal Insulation)
When installing 2P products too tightly, thermal insulation parts (18mm wide, 6mm thick) must be installed between products to facilitate heat dissipation. This new insulation design is easy to install, saves space, and improves heat dissipation.
If the temperature in the distribution box is too high, the capacity of the contactor may need to be reduced.

Figure 5: Thermal Insulation Accessory (Example for GYHC-16/10)
5.4 Outline and Installation Dimensions
Below are various views of the GEYA GYHC Modular Contactor, illustrating its physical form and key dimensions. For precise technical drawings and detailed installation dimensions for all models (1P/2P, 3P/4P, and various current ratings), please refer to the comprehensive PDF user manual linked in the Warranty and Support section.

Figure 6: Side view with general dimensions (e.g., 18mm width for 1P/2P, 36mm for 3P, 54mm for 4P)

Figure 7: Angled view of the Contactor

Figure 8: Bottom view showing terminal layout
5.5 Wiring and Application Examples
The contactor is suitable for various applications including lighting control, heating, ventilation, and motor control in household and commercial settings. Ensure correct wiring according to the specific application and local electrical codes.

Figure 9: Application Examples (EV Charging, Lighting Control, Commercial Water Heater)
6. Operating Instructions
The GEYA GYHC Modular Contactor features a manual control switch, typically located on the front panel, with several positions. Refer to Video 1 in the Product Overview section for a visual demonstration of these positions and their functions.
- Position O (Off): The contactor is in the open state, and the circuit is disconnected.
- Position Auto: The contactor operates automatically based on the control signal (e.g., from a timer or thermostat). This is the default operating mode.
- Position I (On): The contactor is manually forced into the closed state, connecting the circuit.
- Position I+P (Manual Override with Push): This position allows for temporary manual operation. When the switch is moved to 'I+P' and held, the contactor closes. Upon release, it automatically returns to the 'Auto' position. This is useful for testing or temporary manual control.

Figure 10: Front view showing the manual control switch
7. Maintenance
Regular maintenance ensures the longevity and reliable operation of your GEYA GYHC Modular Contactor.
- Visual Inspection: Periodically check the contactor for any signs of physical damage, discoloration, or loose connections.
- Cleaning: Keep the contactor free from dust and debris. Use a dry, soft cloth for cleaning. Do not use solvents or abrasive cleaners.
- Terminal Tightness: Ensure all terminal screws are securely tightened to prevent overheating and poor connections.
- Operational Check: Occasionally test the manual override function to ensure it operates smoothly.
- Environmental Conditions: Verify that the operating environment remains within the specified temperature and humidity ranges.
CAUTION: Always disconnect power before performing any maintenance or inspection.
8. Troubleshooting
If you encounter issues with your GEYA GYHC Modular Contactor, consider the following common troubleshooting steps:
- Contactor Not Engaging:
- Check the control voltage supply. Ensure it is within the specified range (85%~110% Us).
- Verify the control wiring for loose connections or breaks.
- Ensure the manual switch is not stuck in the 'O' (Off) position.
- Check for upstream short-circuit protection devices that may have tripped.
- Contactor Not Disengaging:
- Check if the control signal is continuously applied.
- Ensure the manual switch is not stuck in the 'I' (On) position.
- Verify the release voltage is within the specified range (20%~75% Us).
- Overheating:
- Check for loose terminal connections and retighten if necessary.
- Ensure the load current does not exceed the contactor's rated current.
- Verify that proper thermal insulation is installed between closely mounted 2P contactors.
- Ensure adequate ventilation in the enclosure.
- Unusual Noise:
- While the contactor is designed for super-quiet operation, persistent unusual noise might indicate a mechanical issue or improper installation. Check mounting and connections.
If the problem persists after these checks, consult a qualified electrician or contact GEYA customer support.
9. User Tips
Based on feedback from other users, here are some helpful tips for using your GEYA GYHC Modular Contactor:
- Verify Specifications: Always double-check the specific model (e.g., 4NO vs 2NO2NC) and ensure it matches your application's requirements before installation.
- Quality Assurance: Users consistently report that the product arrives exactly as described and performs reliably.
- Consider Multi-Phase Needs: For three-phase applications, ensure you select a 3P or 4P model with appropriate contact configurations (e.g., 3NO for a simple switch, or 2NO2NC if normally closed contacts are also needed).
10. Frequently Asked Questions (FAQ)
- Q: What is the difference between 4NO and 2NO2NC?
- A: 4NO means the contactor has four Normally Open contacts, which close when the coil is energized. 2NO2NC means it has two Normally Open contacts and two Normally Closed contacts. The Normally Closed contacts open when the coil is energized.
- Q: Can I use a 4P contactor for a three-phase application?
- A: Yes, a 4P contactor can be used for three-phase applications. The fourth pole can be used for a neutral line or an auxiliary contact, depending on the specific model (e.g., 3NO1NC or 4NO). If you only need to switch three phases, the last contact may not be connected.
11. Warranty and Support
For detailed warranty information, technical support, or service inquiries, please refer to the official GEYA documentation or visit the GEYA Official Store website.
A comprehensive user manual in PDF format is available for download: GEYA GYHC Modular Contactor User Manual (PDF).