1. Introduction
The Hantek 2000 series offers a versatile 3-in-1 handheld device combining a Digital Oscilloscope, an Arbitrary Waveform Generator (AWG), and a Digital Multimeter (DMM). This compact and portable tool is designed for various electrical measurement and analysis tasks, suitable for hobbyists, students, and professionals.
This manual provides essential information for the safe and effective use of your Hantek device. Please read it thoroughly before operation.

Video demonstrating the Hantek 3-in-1 oscilloscope, multimeter, and signal generator functions.
2. Product Variants
The Hantek 2000 series comes in several models, each offering a different combination of features and bandwidth:
- Hantek 2C42: 40MHz Bandwidth, 2 Channels, Digital Multimeter (DMM). Does NOT include Waveform Generator.
- Hantek 2D42: 40MHz Bandwidth, 2 Channels, Digital Multimeter (DMM), Arbitrary Waveform Generator (AWG).
- Hantek 2C72: 70MHz Bandwidth, 2 Channels, Digital Multimeter (DMM). Does NOT include Waveform Generator.
- Hantek 2D72: 70MHz Bandwidth, 2 Channels, Digital Multimeter (DMM), Arbitrary Waveform Generator (AWG).
The 'D' in the model number indicates the inclusion of the Arbitrary Waveform Generator (AWG) function.
3. What's in the Box
Upon receiving your Hantek device, please check the package contents. The standard package typically includes:
- Hantek Handheld Oscilloscope Unit
- Oscilloscope Probe(s) (quantity may vary by model)
- Multimeter Test Leads (red and black)
- USB Cable
- Power Adapter
- Carrying Case
- User Manual (this document)

4. Setup
4.1. Battery Installation and Charging
The device comes with a built-in 18650 Lithium-ion battery. While the battery is typically included, it may arrive with a low charge. Connect the device to the provided power adapter using the USB cable to charge it fully before first use.

WARNING: Do not attempt to open the battery compartment or replace the battery yourself. The battery is not designed to be user-demountable. Refer to qualified service personnel for battery-related issues.
4.2. Powering On/Off
Press and hold the power button (usually located on the front panel) to turn the device on or off. The device will display the Hantek logo and then enter the last used mode.
4.3. Connecting Probes
Ensure the device is powered off before connecting or disconnecting probes. Connect the appropriate probes (oscilloscope probes for oscilloscope mode, test leads for multimeter mode) to the corresponding input jacks on the device.
5. Operating Instructions
5.1. General Controls
The device features a clear LCD display and a set of buttons for navigation and function selection:
- F1-F4 Buttons: Context-sensitive function buttons, their labels change based on the current mode.
- Scope Button: Switches to Oscilloscope mode.
- DMM Button: Switches to Digital Multimeter mode.
- AWG Button: Switches to Arbitrary Waveform Generator mode (available on 'D' models only).
- Menu Button: Accesses the main menu for settings and options.
- Navigation Buttons (Up/Down/Left/Right): Used to navigate menus and adjust parameters.
- Enter Button: Confirms selections or enters sub-menus.
- Auto Button: Automatically adjusts oscilloscope settings for optimal waveform display.
- Trig Button: Accesses trigger settings in oscilloscope mode.
- Channel Button: Selects or configures channels in oscilloscope mode.
- Time Button: Adjusts horizontal time base in oscilloscope mode.
5.2. Oscilloscope Mode
To enter Oscilloscope mode, press the Scope button.
- Connecting Probes: Connect the oscilloscope probe(s) to the CH1 and/or CH2 BNC inputs. Ensure the probe's ground clip is connected to the circuit's ground.
- Probe Attenuation: Set the probe's attenuation switch (e.g., 1X, 10X) to match the setting in the oscilloscope menu to ensure accurate readings.
- Adjusting Display:
- Use the Channel button to select and adjust vertical scale (Volts/Div) for each channel.
- Use the Time button to adjust the horizontal time base (Sec/Div).
- Press Auto for automatic setup of vertical and horizontal scales.
- Triggering: Use the Trig button to access trigger settings. Proper triggering stabilizes the waveform on the screen.
- Measurements: The oscilloscope can perform various automatic measurements (e.g., frequency, amplitude). Use the menu options to select and display these measurements.
- Storage Function: The device supports waveform storage. Refer to the menu for options to save and recall waveforms.
- Cursor Measurement: Use cursors to manually measure specific points on the waveform.
- X-Y Mode: The device supports X-Y mode (CH1 vs CH2) for phase relationship analysis.
- Roll Mode: This model supports 'ROLL MODE' for viewing slow-changing signals.

5.3. Digital Multimeter (DMM) Mode
To enter Multimeter mode, press the DMM button.
- Connecting Test Leads: Connect the red test lead to the V/Ω/C/+ input and the black test lead to the COM input for voltage, resistance, capacitance, and diode measurements. For current measurements, connect the red lead to the A or mA input depending on the expected current range.
- Function Selection: Use the F1-F4 buttons or navigation keys to select the desired measurement function (e.g., DC Voltage, AC Voltage, Resistance, Diode Test, Capacitance, Continuity).
- Taking Measurements: Apply the test leads to the circuit or component under test. The measurement will be displayed on the screen.

5.4. Arbitrary Waveform Generator (AWG) Mode (2D Models Only)
To enter AWG mode, press the AWG button.
- Connecting Output: Connect a BNC cable from the 'Gen Out' port to the circuit where the signal is needed.
- Waveform Selection: Use the F1-F4 buttons or navigation keys to select the desired waveform type (Sine, Square, Triangular, Trapezoid, Arbitrary).
- Parameter Adjustment: Adjust parameters such as frequency, amplitude, and offset using the navigation buttons and menu options.
- Outputting Signal: Enable the output function to generate the selected waveform.

6. Maintenance
6.1. Cleaning
Regularly clean the device with a soft, dry cloth. For stubborn dirt, use a slightly damp cloth with mild detergent, then wipe dry. Do not use abrasive cleaners or solvents.
6.2. Battery Care
- Charge the battery fully before long periods of storage.
- If the device is not used for an extended time, charge it periodically (e.g., every 3 months) to maintain battery health.
- If the battery is completely drained, it may take some time on the charger before the device powers on.
6.3. Storage
Store the device in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. Disconnect all probes and cables before storage.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on | Low or depleted battery | Connect to power adapter and charge for at least 30 minutes before attempting to power on. |
| No waveform displayed in Oscilloscope mode | Incorrect probe connection, wrong settings, no signal input | Check probe connections, ensure probe attenuation matches device setting, press 'Auto' button, verify signal source. |
| Inaccurate Multimeter readings | Incorrect test lead connection, wrong function selected, faulty component | Ensure test leads are connected to correct ports for the selected function. Double-check the component. |
| PC software not detecting device | Driver issues, faulty USB cable, incorrect USB port | Install/reinstall latest drivers from Hantek website. Try a different USB cable or port on your computer. |
| Signal appears to 'float' or is unstable at higher frequencies | Limitations of the device, improper grounding, probe issues | Ensure proper grounding. Use high-quality probes. Be aware of the device's bandwidth limitations, especially for professional use. |
| Display damage (e.g., lines on screen) | Physical damage, internal connection issue | This indicates a hardware fault. Contact Hantek Official Store for support. |
8. Specifications
8.1. General Specifications
- Brand Name: Hantek
- Origin: Mainland China
- Certification: CE
- Display Resolution: 320*240 Pixels
- Battery Included: Yes
- Battery Type: 18650 Lithium-ion (not user-demountable)
- Package Dimensions: 26cm (L) x 21cm (W) x 11cm (H)
- Package Weight: 1.4 kg
8.2. Oscilloscope Specifications
| Feature | Specification |
|---|---|
| Digital Channels | 2 |
| Bandwidth | 40MHz (2C42, 2D42), 70MHz (2C72, 2D72) |
| Sampling Rate | 250MSa/s (single channel), 125MSa/s (dual channel) |
| Max Waveform Capture Rate | 30,000wfm/s |
| Vertical Resolution | 10mV to 10V/div |
| Horizontal Resolution | 50ns/div |
| Record Length | As described |
| Input Coupling | AC, DC, GND |
| Input Impedance | 1MΩ ±2%, in parallel with 10pF±5pF |
| Max Input Voltage | 400V (DC+AC Peak) |
| Automatic Measurements | Yes (Frequency, Amplitude, etc.) |
| Storage Function | Yes |
| Cursor Measurement | Yes |
| X-Y Mode | Yes |
| Roll Mode | Yes |
8.3. Digital Multimeter (DMM) Specifications
| Feature | Specification |
|---|---|
| Display Counts | 4000 counts |
| Measurements | AC/DC Voltage, AC/DC Current, Resistance, Diode Testing, Capacitance, Continuity Test |
| Input Protection | 10A MAX UNFUSED, 200mA MAX FUSED, CAT II 600V |
8.4. Arbitrary Waveform Generator (AWG) Specifications (2D Models Only)
| Feature | Specification |
|---|---|
| Sampling Rate | 250MSa/s |
| Vertical Resolution | 12-bits |
| Sine Wave Frequency | 1Hz to 25MHz |
| Square Wave Frequency | 1Hz to 10MHz |
| Triangular Wave Frequency | 1Hz to 1MHz |
| Trapezoid Wave Frequency | 1Hz to 5MHz |
| Output Impedance | 50 Ohm |
| Amplitude | Max 5V (with offset capability) |
9. User Tips
- PC Software: Hantek provides PC software for viewing signals on a larger screen and for firmware updates. This can be downloaded from the official Hantek website.
- High Voltage Measurements: For measuring high voltages (e.g., 220VAC), ensure you use an appropriate high-voltage probe (e.g., 100X or 1000X) to avoid damaging the device and for safety.
- Multimeter Accuracy: While the DMM function is convenient, for highly precise measurements, a dedicated high-precision multimeter might be preferred.
- Advanced Use: Some users have reported successfully flashing 'C' models to 'D' models to enable AWG functionality. This is an unofficial modification and should be attempted at your own risk, as it may void your warranty.
- Automotive Diagnostics: The device is suitable for automotive electrical diagnostics, including CAN bus analysis, with the right probes and settings.
- Simultaneous Operation: The waveform generator and oscilloscope can be used simultaneously, allowing you to inject a signal and observe its effects on a circuit.
10. Warranty and Support
Your Hantek device is covered by a manufacturer's warranty against defects in materials and workmanship. The duration and terms of the warranty may vary by region and retailer. Please retain your proof of purchase for warranty claims.
For technical support, warranty service, or inquiries about replacement parts, please contact the Hantek Official Store or your authorized reseller. Provide your model number and a detailed description of the issue to facilitate faster service.