1. Introduction
The Mestek 800C Digital Infrared Thermometer is a versatile, non-contact temperature measurement device designed for industrial use. It features a color screen, data hold function, adjustable emissivity, and a 12:1 Distance-to-Spot ratio. This model also supports K-type temperature probe measurements and humidity testing. This manual provides essential information for safe and effective operation.

Figure 1: Mestek 800C Digital Infrared Thermometer showing its main features and accessories.
2. Safety Information
Please read all safety warnings and instructions before using this product to prevent injury or damage to the device.
- Do not point the laser directly at eyes or indirectly off reflective surfaces.
- This device is for industrial use and is not intended for measuring human body temperature.
- Keep the device away from children.
- Do not use the device in explosive gas, vapor, or dust environments.
- Do not immerse the device in water.
3. Setup
3.1. Battery Installation
The thermometer requires 2 x 1.5V AAA batteries (not included).
- Locate the battery compartment on the handle of the device.
- Open the battery cover.
- Insert two AAA batteries, ensuring correct polarity (+/-).
- Close the battery cover securely.
3.2. K-Type Temperature Probe Connection
For contact temperature measurements, connect the K-type temperature probe:
- Locate the K-type probe input port on the side of the thermometer.
- Insert the K-type probe connector firmly into the port.

Figure 2: Using the K-type temperature probe for contact measurements.
3.3. Initial Power On
Press the trigger to turn on the device. The color screen will illuminate, displaying the current readings.
Video 1: Unboxing and initial overview of the Mestek Infrared Thermometer, showing components and battery compartment.
4. Operating Instructions
4.1. Infrared (Non-Contact) Measurement
- Point the thermometer at the target object.
- Press and hold the trigger. The laser pointer will activate (if enabled) to indicate the measurement area.
- The temperature reading will be displayed on the screen. Release the trigger to hold the data.

Figure 3: Non-contact temperature measurement of food using the infrared function.
4.2. K-Type Probe Measurement
Once the K-type probe is connected, the device may automatically switch to probe mode or require a mode selection. Refer to the on-screen indicators.
- Place the metal tip of the K-type probe in contact with the object whose internal temperature you wish to measure.
- The temperature reading from the probe will be displayed.
4.3. Mode Selection (MODE Button)
Press the 'MODE' button to cycle through various display modes or settings, which may include:
- Infrared temperature display
- K-type probe temperature display
- Humidity display
- MAX/MIN/AVG temperature display
- Emissivity adjustment
- High/Low temperature alarm settings
4.4. Unit Conversion (°C/°F)
Use the dedicated °C/°F button or navigate through the 'MODE' settings to switch between Celsius and Fahrenheit units.
4.5. Emissivity Adjustment
Emissivity (ε) is crucial for accurate infrared measurements. Different materials have different emissivities. The device allows adjustment from 0.1 to 1.0. Consult an emissivity table for common materials. Adjust this value via the 'MODE' button and arrow keys.
4.6. Laser Pointer On/Off
The laser pointer assists in aiming. It can be toggled on or off using a dedicated button or through the 'MODE' settings.
4.7. Backlight
The screen backlight can be turned on or off for better visibility in different lighting conditions.
4.8. Automatic Shutdown
The device features an automatic shutdown function after a period of inactivity to conserve battery life.

Figure 4: Examples of industrial applications: measuring automobile engine and air conditioning temperatures.

Figure 5: Further applications: measuring oven food and boiler temperatures.
5. Maintenance
5.1. Cleaning
- Use a soft, damp cloth to clean the device casing. Do not use abrasive cleaners or solvents.
- Carefully clean the infrared lens with a soft cloth or cotton swab, avoiding scratches.
5.2. Battery Replacement
Replace batteries when the low battery indicator appears on the screen to ensure accurate readings and proper operation.
5.3. Storage
When not in use for extended periods, remove the batteries and store the device in a cool, dry place, preferably in its protective carrying case.
6. Troubleshooting
6.1. Inaccurate Readings
- Check Emissivity: Ensure the emissivity setting matches the material being measured. Incorrect emissivity is a common cause of inaccurate readings.
- Distance to Spot Ratio: Maintain the recommended distance to the target. The 12:1 D:S ratio means that at 12 inches from the target, the measurement area is a 1-inch circle. Measuring too far or too close can affect accuracy.
- Surface Conditions: Highly reflective surfaces can cause inaccurate readings. Consider applying a non-reflective matte black paint or tape to the surface for more accurate measurement.
- Ambient Conditions: Extreme ambient temperatures or rapid changes can affect sensor performance. Allow the device to stabilize in the environment before use.
6.2. Device Not Turning On
- Check Batteries: Ensure batteries are correctly installed and not depleted. Replace if necessary.
- Battery Contacts: Clean battery contacts if they appear corroded.
6.3. Laser Not Working
- Check Laser Setting: Ensure the laser pointer is enabled in the device settings.
7. Specifications
| Feature | Specification |
|---|---|
| Measurement Range (Infrared) | -50°C to 800°C (-58°F to 1472°F) |
| Measurement Range (K-Type Probe) | -10°C to 500°C (14°F to 932°F) |
| Accuracy (Infrared) | ±2°C (for 800C model), ±1.5°C (for IR600 model) |
| Accuracy (K-Type Probe) | ±(1.5% + 2°C/4°F) |
| Distance to Spot Ratio (D:S) | 12:1 |
| Emissivity | 0.1 ~ 1 adjustable |
| Response Time | 0.5 Seconds |
| Response Wavelength | 8 ~ 14 µm |
| Resolution | 0.1°C/°F |
| Display Type | Digital Color Screen |
| Power Supply | 2 x 1.5V AAA Battery (not included) |
| Humidity Accuracy | ±1% RH |
| Features | Data Hold, Positioning Laser On/Off, Backlight, Automatic Shutdown, Celsius/Fahrenheit Unit Conversion, High/Low Temperature Alarm (IR600 model) |
| Certifications | CE, RoHS |

Figure 6: Detailed specifications for the IR600 model, including range, accuracy, and features.
8. User Tips
- Optimal Distance: For infrared measurements, the closer you are to the object, the more accurate the reading, but avoid getting closer than 10 cm (approximately 4 inches) to ensure the sensor can properly focus.
- Emissivity Settings: Take time to understand and adjust the emissivity setting for different materials to achieve the most accurate results. While it might seem inconvenient, it's crucial for precision.
- Not for Medical Use: This is an industrial thermometer. Do not use it for measuring human body temperature, as it is not calibrated for medical accuracy.
- Versatile Applications: The thermometer works effectively for a wide range of applications, including measuring temperatures of roasted foods, automobile engines, air conditioning units, ovens, and boilers.
- Probe for Internal Temps: Use the K-type probe for accurate internal temperature readings of liquids or semi-solids, complementing the surface measurements from the infrared sensor.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.