1. Introduction
This manual provides instructions for the safe and efficient use of your MXPOKWV 60V 20AH Lead Acid Battery Charger. This smart power charger is designed for 60V lead acid, AGM, and Gel batteries, commonly found in electric cars and toy cars. Please read this manual thoroughly before first use to ensure proper operation and safety.
2. Safety Information
2.1 General Warnings
- This product is intended for 60V lead acid batteries (including AGM and Gel types) ONLY. Do NOT use with Lithium batteries or other battery types.
- Charge indoors in a dry area.
- Keep away from wet surfaces and rain.
- Keep away from flammable materials.
- Keep away from children.
- Do NOT disassemble the charger.
- Do NOT connect the charger to a battery for more than 12 hours.
- WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
2.2 Built-in Protections
- Short Circuit Protection
- Over Current Protection
- Battery Polarity Reversal Protection
3. Product Overview
3.1 Components
- 1 x MXPOKWV 60V 20AH Lead Acid Battery Charger Unit
- 1 x AC Power Cord (with selected plug type: US, EU, UK, or AU)
3.2 Specifications
| Feature | Specification |
|---|---|
| Model | 60V 20AH lead acid agm gel charger |
| Input Voltage | AC 220V / 50Hz |
| Output Voltage | DC 73V-74.1V |
| Output Current | 3A DC |
| Max. Output Power | 250W |
| Suitable Battery Range | 60V 10AH-20AH Lead Acid Battery/Gel Battery (e.g., 5x 12V lead acid batteries) |
| Certifications | CE, CCC |
| Dimensions | 16cm x 8cm x 6cm (approx.) |
| Weight | 0.55 kg (approx.) |
| Charging Time | 5-8 hours (for 10AH-20AH batteries) |
| Features | Intelligent Charge, Zero voltage output on open circuit |
3.3 LED Indicators
- Red Light: Indicates the battery is currently charging.
- Green Light: Indicates the battery is fully charged.
4. Setup
- Verify Power Supply: Ensure the charger's input voltage (AC 220V/50Hz) matches your local power supply.
- Select Plug Type: If applicable, ensure you have the appropriate plug type (US, EU, UK, AU) for your region.
- Connect AC Cord: Connect the AC power cord to the charger's input port.
- Identify Battery Connector: Identify the correct output connector for your 60V lead acid battery. The charger features a standard output connector.
5. Operation
- Connect to Battery: Carefully connect the charger's output connector to your 60V lead acid battery. Ensure correct polarity. The charger features "Zero Voltage Output On Open Circuit" for safety, meaning it will not output voltage until a battery is connected.
- Connect to Power: Plug the AC power cord into a suitable wall outlet.
- Charging Indication: The LED indicator on the charger will turn RED, signifying that charging is in progress.
- Full Charge Indication: Once the battery is fully charged, the LED indicator will turn GREEN. The charger features automatic conversion to prevent overcharging.
- Disconnect: After the battery is fully charged (green light), first unplug the charger from the wall outlet, then disconnect the charger from the battery.
- Charging Duration: Typical charging time for 10AH-20AH batteries is 5-8 hours. Avoid leaving the charger connected to the battery for more than 12 hours.
6. Maintenance
- Cleaning: Keep the charger clean and free from dust. Use a dry cloth for cleaning.
- Storage: Store the charger in a dry, cool place when not in use.
- Inspection: Periodically inspect the power cord and connectors for any signs of damage. Do not use if damaged.
- Temperature: The charger is designed to operate efficiently within a temperature range of -25°C to 55°C, with effective heat dissipation.
7. Troubleshooting
- Charger not turning on/LED not lighting up:
- Check if the AC power cord is securely plugged into both the charger and the wall outlet.
- Ensure the wall outlet is functional.
- Verify the charger's input voltage (AC 220V/50Hz) matches your power supply.
- Charger LED remains red after extended period:
- Ensure the battery capacity is within the recommended range (10AH-20AH).
- Check the battery's condition; a severely discharged or faulty battery may take longer to charge or not charge fully.
- Do not exceed 12 hours of continuous charging.
- Charger LED is green but battery is not fully charged:
- Verify the battery is a 60V lead acid type. This charger is not suitable for other battery chemistries.
- Check the connections for looseness.
8. User Tips
- Always ensure the charger's plug type matches your region's electrical outlets.
- For optimal battery life, avoid deep discharge of your lead acid batteries.
- The "Zero Voltage Output On Open Circuit" feature means the charger will not output voltage until a battery is connected, enhancing safety.
9. Compliance
- This product is CE and CCC certified, indicating compliance with relevant European and Chinese safety standards.
- California Proposition 65 Warning: This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
10. Support
For further details, technical assistance, or warranty information, please refer to the official user manual available in PDF format: