ATORCH J7-c USB Digital Tester

Contents

ATORCH J7-c USB Digital Tester Instruction Manual

Model: J7-c USB Digital Tester

1. Introduction

ATORCH USB Digital Tester (Bluetooth Curved version MAX 6.5A) with display examples and system settings

Figure 1.1: ATORCH J7-c USB Digital Tester

This image shows the ATORCH J7-c USB Digital Tester, highlighting its curved design, maximum 6.5A current capability, and various display modes including voltage/current curves and system settings. The Bluetooth version includes a chip for app connectivity.

The ATORCH J7-c USB Digital Tester is a versatile instrument designed to monitor various electrical parameters of USB connections. It can measure voltage, current, capacity, electric quantity, power, load impedance, D+/D- voltage, and charging time. This tester supports multiple quick charging protocols, including Type-C PD (up to 45W and 87W), Qualcomm QC2.0 (5V/9V/12V/20V), Qualcomm QC3.0 (3.8~12V +/- 0.2 step), Android BC1.2 (5V), Apple iPhone (5V/2.4A), and MTK-PE (5V/7V/9V/12V). It also features OTG functionality and can be used for U disk readings and computer USB interface data transfer voltage and current measurements.

This manual provides detailed instructions for setting up, operating, and troubleshooting your ATORCH J7-c USB Digital Tester.

2. Product Overview

The ATORCH J7-c USB Digital Tester features a compact design with multiple input/output ports and a clear display for real-time data monitoring.

Diagram showing the ports of the USB Digital Tester

Figure 2.1: USB Digital Tester Port Diagram

This diagram illustrates the various input and output ports on the ATORCH J7-c USB Digital Tester, including USB Input, Micro USB Input, Type-C Input, Type-C Output, USB Output, and the function Key.

2.1. Components

  • USB Input: Standard USB-A male connector for power input.
  • Micro USB Input: Micro USB port for power input, also used for PD protocol triggering.
  • Type-C Input: USB-C male connector for power input.
  • Type-C Output: USB-C female port for connecting devices to be tested.
  • USB Output: Standard USB-A female port for connecting devices to be tested.
  • Key: Multi-function button for navigating menus and controlling settings.
  • Display: High-definition color screen for displaying measurement data.

2.2. Display Interfaces

The tester offers a 12-in-1 display interface, allowing users to view various parameters. The display can be navigated using the function key.

Flowchart illustrating the 12-in-1 display interface and key operation

Figure 2.2: Display Interface Flowchart

This flowchart details the various screens available on the USB Digital Tester, including startup, different measurement displays (voltage, current, power, capacity, temperature), USB four-wire detection, background calibration, and alarm settings, along with key press actions for navigation.

3. Specifications

ParameterValueResolution/Precision
Voltage Measuring Range3.6V ~ 32.0V0.01V
Current Measuring Range0.00 ~ 8.00A0.01A (Max test current 8.00A)
Capacity Cumulative Range0 ~ 99999mAh0.01Ah
Power Cumulative Range0 ~ 99999Wh0.01Wh
Power Metering Range000.00 ~ 150.00W0.01W
Impedance Measuring Range1 ~ 999.9Ω0.1Ω
Temperature Measuring Range0 ~ 80℃1℃
Timing Measuring Range999 Hours 59 Minutes 59 Seconds1s
USB D+ Voltage Range0V ~ 2.99V0.01V
USB D- Voltage Range0V ~ 2.99V0.01V
Time to Refresh500mS/times
Measurement Rate0.5 times/s
Alarm ModeDisplay Hints
Product Size61mm x 68mm x 10.8mm
Self-consumable Flow<0.02A
Working Temperature-10 ~ +60℃
Working Humidity10 ~ 80% (non-condensing)
Pressure of Work80 ~ 106kPa
CertificationRoHS, CE
Power SupplyUSB DC Power
Display TypeDigital Only
Accuracy Class1% (Software calibration technique)

3.1. Supported Fast Charging Protocols

  • Qualcomm QC2.0 (5V / 9V / 12V / 20V)
  • Qualcomm QC3.0 (3.8 ~ 12V +/- 0.2 step)
  • Android BC1.2 (5V)
  • Apple iPhone (5V / 2.4A)
  • MTK-PE (5V / 7V / 9V / 12V)
  • Type-C PD (up to 45W and 87W, supports Apple 8/X/8 Plus, MacBook quick charging: 29W power, 5V3A / 9V3A / 12V2.5A / 15V2A)
  • Huawei FCP/SCP (supports HUAWEI 4.5A super fast charging current)
  • Samsung AFC
Images demonstrating voltage and current accuracy evaluation of the USB Digital Tester

Figure 3.1: Voltage and Current Accuracy Evaluation

This image displays the USB Digital Tester undergoing voltage and current accuracy evaluation using professional testing equipment, indicating its precision in measurements.

4. Setup

To begin using your ATORCH J7-c USB Digital Tester, follow these steps:

4.1. Basic Connection

  1. Connect the USB Input (USB-A male) or Type-C Input (USB-C male) of the tester into a power source (e.g., wall charger, power bank, computer USB port).
  2. Connect your device (e.g., smartphone, tablet, USB fan) to the USB Output (USB-A female) or Type-C Output (USB-C female) port of the tester.
  3. The display will automatically turn on and show real-time measurement data.

4.2. Triggering PD Protocol (for PD Chargers)

When testing PD (Power Delivery) chargers, especially if the output is not connected to a PD protocol device, the tester may not display data correctly. To ensure proper functionality and trigger the PD protocol:

  1. Insert the included Micro USB adapter into the Micro USB Input port of the tester.
  2. Connect the Micro USB adapter to the PD charger.
  3. Ensure the Type-C input and Type-C output of the tester are connected to the mobile phone. This setup will trigger the PD protocol, and the PD charger will work normally.
Diagram showing correct and incorrect connections for triggering PD protocol

Figure 4.1: PD Protocol Triggering Guide

This image provides important tips on how to correctly trigger the PD protocol when using the USB Digital Tester with PD chargers, illustrating both incorrect and correct connection methods.

4.3. Bluetooth Connection (Bluetooth Version Only)

For the Bluetooth version of the J7-c tester, you can connect it to a mobile phone (iOS or Android 5.0+) or a PC (Windows 7/10) to view and log data via an application.

  1. Download the APP:
  2. Install the APP on your phone or PC.
  3. Connect the Tester: Plug the J7-c USB tester into a USB charger. The Bluetooth indicator will light up.
  4. Pair with APP:
    • For Mobile APP: Open the E-test APP. Do NOT pair via your phone's Bluetooth settings. Directly click the Bluetooth icon within the E-test APP. Select the "_BLE" Bluetooth name to connect.
    • For PC APP: Open the PC software. The Bluetooth pairing password is "0000" or "1234". Select the "_SPP" Bluetooth name to connect.
Step-by-step guide for J7-c Bluetooth connection method

Figure 4.2: Bluetooth Connection Method

This image illustrates the steps to connect the J7-c USB tester via Bluetooth to a mobile application, showing the tester, phone app interface, and the Bluetooth indicator.

5. Operation

5.1. Key Button Operations

The single function button on the tester controls various display modes and settings:

  • Short Press: Switches between different display screens (e.g., voltage/current, capacity, power, temperature, D+/D- voltage).
  • Quick Double-Click: Resets the accumulated capacity (mAh) to zero.
  • Quick Triple-Click: Resets the accumulated electric quantity (Wh) to zero.
  • Quick Four-Click: Resets the timing (00:00:00) for the current group to zero.
  • Quick Five-Click: Changes the cumulative data storage group number (NO.X, 10 groups of data available).
  • Long Press (Hold): Resets the capacity, power, and time for the current group simultaneously.

5.2. System Settings

To access and adjust system settings:

  1. When on the System Settings interface (accessed by short pressing the button until you reach it), long press the button to enter the setting mode.
  2. Short press to switch between setting columns.
  3. Long press on a specific column to execute or modify its value.
    • When a value is flashing, double-click to increase (+) or triple-click to decrease (-).
    • Long press during adjustment for continuous increase or decrease.
    • After adjustment, "OK" will display, and the system will automatically save the value. The tester will then automatically exit the setting interface.

Available System Settings:

  • >32.0V (OVP/Overvoltage Protection): Set the overvoltage alarm threshold.
  • <0.00V (LVP/Low Voltage Protection): Set the low voltage alarm threshold.
  • >8.00A (OPC/Overcurrent Protection): Set the overcurrent alarm threshold.
  • Screen Rotation: Flips the display 180 degrees. Useful if the tester is plugged in an inverted position.
  • Default Setting: Restores factory settings.
  • Clear Data: Clears all stored data.
  • USB IAP/USB Upgrade: For firmware updates.
  • Exit: Exits the system settings menu.

5.3. Curve Interface Operation

When on the curve interface:

  • Long Press: Switches the refresh rate of the curve display (0.5S, 1S, 2S, 5S).
  • Quick Double-Click: Toggles between stopping and continuing the curve update.

5.4. Testing Applications

The J7-c tester can be used for various testing scenarios:

  • Test Capacity and Electric Energy of Power Bank:

    Fully charge the power bank, then connect the USB Tester. Reset the capacity and electric energy by long-pressing the button. Connect your phone or other discharging device. The reading on the multimeter will show the real data of your power bank's capacity.

    Image showing the USB Digital Tester connected to a power bank and a fan

    Figure 5.1: Power Bank Capacity Test

    This image demonstrates how to use the USB Digital Tester to measure the capacity and electric energy of a power bank by connecting it to a power bank and a USB fan as a load.

  • Test Charger:

    Insert the USB Tester into a USB charging port. Use an adjustable constant current tester to detect the current and voltage data of the charger.

    Image showing the USB Digital Tester connected to a wall charger and a phone

    Figure 5.2: Charger Test Setup

    This image illustrates the setup for testing a charger using the USB Digital Tester, connected between a wall charger and a mobile phone.

  • Checking USB Cable Quality:

    Under constant power supply and sustained load, a larger voltage drop and lower voltage output detected by the tester indicate poorer USB cable quality. A smaller voltage drop signifies a better quality cable.

  • Two-Way Current Charging:

    The tester supports two-way current charging. Whether plugged into a Type-C charger or a Type-C mobile phone, it can facilitate charging and measurement.

    Image demonstrating the USB Digital Tester supporting two-way current charging

    Figure 5.3: Two-Way Charging Support

    This image shows the USB Digital Tester facilitating two-way current charging, with a phone charging from a power bank through the tester.

6. Advanced Features (Bluetooth Version Only)

The Bluetooth version of the ATORCH J7-c offers enhanced functionality through its mobile and PC applications.

6.1. APP Functionality

  • Real-time Monitoring: View all measurement parameters on your phone or PC screen.
  • Data Logging: Record and export measurement data for analysis.
  • Remote Control: Adjust certain settings or trigger functions from the app.
  • Curve Display: Monitor voltage and current curves over time.
Image showing the Bluetooth version of the USB Digital Tester with app interfaces

Figure 6.1: Bluetooth Version with APP Connectivity

This image displays the Bluetooth version of the USB Digital Tester alongside a laptop and a smartphone, illustrating its capability to connect to applications for data monitoring and control.

7. Maintenance

To ensure the longevity and optimal performance of your ATORCH J7-c USB Digital Tester:

  • Keep the device clean and dry. Use a soft, dry cloth to wipe the exterior.
  • Avoid exposing the device to dust, dirt, or liquids.
  • Store the device in a cool, dry place when not in use.
  • Do not attempt to open or repair the device yourself, as this may damage it and void the warranty.

8. Troubleshooting

8.1. General Issues

  • Tester not displaying when plugged into PD charger: Ensure you are using the Micro USB adapter to trigger the PD protocol and that a mobile device is connected to the Type-C output. Refer to Section 4.2.
  • Inaccurate readings: The device has an accuracy class of 1% (software calibration technique). Avoid calibrating voltage or current without standard instruments. According to user feedback, current calibration can be very accurate from 200-2500mA after calibration at 5V, but voltage below 4V may be less accurate.
  • Resetting accumulated data (mAh, Wh, Time):
    • Capacity (mAh): Quick double-click the button.
    • Electric quantity (Wh): Quick triple-click the button.
    • Timing: Quick four-click the button.
    • All (Capacity, Power, Time): Long press the button.

8.2. Bluetooth and APP Issues (Bluetooth Version Only)

  • APP crashes or incompatibilities: Before purchasing, download and install the APP to ensure compatibility with your device. The PC software supports Windows 7 and 10. The mobile APP supports Android 5.0+ and iOS.
  • Blank APP screen or signal list not displayed:

    Ensure your mobile phone's GPS positioning is turned on. Alternatively, go to your phone's settings, find the E-test APP, and grant permissions for location information or storage information. Then, reconnect.

    Steps for enabling Bluetooth connection in the E-Test APP by adjusting phone settings for app permissions

    Figure 8.1: APP Permission Settings for Bluetooth

    This image provides a step-by-step guide on how to adjust phone settings to grant necessary permissions (Storage and Location) for the E-Test APP to ensure proper Bluetooth connection and functionality.

  • Difficulty connecting via Bluetooth: Do not pair the device through your phone's standard Bluetooth settings. Connect directly from within the E-test APP by clicking the Bluetooth symbol and selecting the appropriate "_BLE" (for mobile) or "_SPP" (for PC) name.
  • Computer pairing password: Use "0000" or "1234".

9. User Tips

  • Consider the Bluetooth Version: If you anticipate needing to monitor data in hard-to-reach places or prefer viewing data on a larger screen, the Bluetooth version is highly recommended. It allows you to access information on your phone or PC, making it much more convenient than relying solely on the small built-in display.
  • Value for Money: While this tester might be more expensive than some alternatives, its comprehensive features, accuracy, and data logging capabilities (with the Bluetooth version) make it a worthwhile investment for serious monitoring.
  • Explore Online Resources: For advanced usage or specific testing scenarios not covered in this manual, consider searching for tutorials or demonstrations on platforms like YouTube.
  • Verify APP Compatibility First: Before purchasing the Bluetooth version, it is crucial to download and test the E-test APP on your mobile device or PC. This will confirm compatibility and prevent potential issues with software functionality.

10. Safety Information

Please read and follow these safety guidelines to ensure safe operation and prolong the life of your device:

  • Do Not Disassemble: Do not attempt to remove or disassemble the device. This can lead to electric shock and will void any warranty.
  • Indoor Use Only: Use the device in a dry, indoor environment. Avoid exposure to moisture, extreme temperatures, or direct sunlight.
  • Avoid Overload: Do not exceed the maximum specified voltage (32.0V) or current (8.00A) limits.
  • Handle with Care: The device contains sensitive electronic components. Avoid dropping or subjecting it to strong impacts.
Back view of the USB Digital Tester showing product name, model, voltage/current range, function, and warning labels

Figure 10.1: Product Warning Labels

This image shows the back of the USB Digital Tester, highlighting important product information and safety warnings, including "Do not remove, to prevent electric shock!" and "Please use in indoor dry place!".

11. Warranty and Support

ATORCH products are manufactured to high-quality standards. For any issues or inquiries, please contact your retailer or the manufacturer's customer support. Keep your purchase receipt as proof of purchase for warranty claims.

For technical support and further information, please refer to the official ATORCH website or the provided APP download links for additional resources.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.