1. Introduction and Overview
The RETEKESS T-AC04 is a robust and versatile RFID Door Access Control System designed for secure entry management. Featuring an IP68 waterproof rating and a strong zinc alloy anti-vandal case, it is suitable for both indoor and outdoor environments, including warehouses, homes, and garages. This system supports up to 2000 users with multiple access methods, ensuring convenient and reliable security.
2. Key Features
- Waterproof Grade: IP68 (highest grade), ensuring durability in harsh conditions.
- Durable Design: Features a strong Zinc Alloy Electroplated anti-vandal case with a soft keyboard backlight for visibility in low-light conditions.
- High Capacity: Supports 2000 user cards and 2000 access codes.
- Multiple Access Methods: Users can gain entry via RFID cards, PIN codes, or a combination of card + code.
- Low Power Consumption: Static current is less than 30mA.
- User-Resettable Passwords: Allows individual users to reset their private passwords for enhanced security.
- Lost Card Deletion: Provides a function to delete lost cards directly from the keypad for immediate security.
- Short-Circuit Protection: Relay output automatically shuts off within 0.1ms upon detecting a short circuit.
- Adjustable Door Output Time: Customizable door open time.
- Fast Operation: Operating speed is less than 20ms, even with 2000 users.
3. Setup and Installation
Before installation, ensure all power is disconnected. The T-AC04 is designed for easy mounting and wiring.
3.1 Package Contents
Verify that your package contains the following items:
- 1 x RETEKESS T-AC04 Access Control Unit
- 1 x English User Manual
- Mounting Screws and Wall Plugs
- Hex Key (for securing the unit)

3.2 Mounting the Unit
- Choose a suitable mounting location, ensuring it is a flat surface.
- Use the provided screws and wall plugs to securely attach the unit to the wall.
- Ensure the unit is firmly fixed to prevent tampering.
3.3 Wiring Diagram
Carefully follow the wiring instructions below. Incorrect wiring can damage the device or connected components. The unit requires a 12VDC power supply.

| Terminal Label | Wire Color | Function |
|---|---|---|
| BELL-A | Pink | Doorbell Output A |
| BELL-B | Pink | Doorbell Output B |
| D0 | Green | Data Line 0 (Wiegand) |
| D1 | White | Data Line 1 (Wiegand) |
| ALARM | Grey | Alarm Output |
| OPEN | Yellow | Open Button Input |
| D_IN | Brown | Door Status Input |
| DC 12V-24V | Red | Power Input (Positive) |
| GND | Black | Ground |
| NO | Blue | Normally Open (Lock Output) |
| COM | Purple | Common (Lock Output) |
| NC | Orange | Normally Closed (Lock Output) |
4. Operating Instructions
All operations and programming are performed directly on the keypad. The soft backlight ensures visibility even at night.
4.1 Access Methods
The T-AC04 supports three primary ways to gain access:
- Card: Present a registered RFID card to the reader.
- Code: Enter a valid 4-digit PIN code on the keypad.
- Card + Code: Present a registered RFID card, then enter a valid 4-digit PIN code.

4.2 Programming and Settings
Refer to the included English User Manual for detailed instructions on:
- Adding and deleting user cards and codes.
- Changing the master password.
- Adjusting the door delay time (door open time).
- Modifying the access mode (Card Only, Code Only, Card + Code).
- Deleting lost cards for security purposes.



5. Maintenance
The RETEKESS T-AC04 is designed for minimal maintenance due to its robust construction and IP68 waterproof rating. To ensure optimal performance and longevity:
- Regularly wipe the keypad surface with a soft, damp cloth to remove dust and grime. Avoid abrasive cleaners.
- Inspect the wiring connections periodically to ensure they are secure and free from corrosion or damage.
- Ensure the unit is not subjected to extreme physical impact, despite its anti-vandal design.
6. Troubleshooting
If you encounter issues with your T-AC04 access control system, consider the following:
- No Power/Unit Unresponsive: Check the power supply connections. Ensure the unit is receiving a stable 12VDC power.
- Door Not Unlocking: Verify that the correct card or code is being used. Check the wiring to the electric lock (NO/COM/NC) for proper connection. Ensure the door delay time is set appropriately.
- Lost Card Security: If a card is lost, immediately use the keypad function to delete it from the system to prevent unauthorized access.
- Wire Cut Protection: The system is designed to lock the door if the wiring is cut, enhancing security. If the door is unexpectedly locked, check for any severed wires.
- Short Circuit Protection: The unit has built-in short-circuit protection for the relay output, which will shut off in 0.1ms. If the lock is not responding, check for potential short circuits in the lock wiring.
7. Specifications
| Parameter | Value |
|---|---|
| Power Supply | 12VDC ± 10% |
| Unlock Relay | 12VDC/2A |
| Electric Lock Output | Max 3A |
| Output Short-Circuit Protection Time | Max 0.1ms |
| Effective Cards/Users | 2000 |
| Ambient Temperature | -45℃ ~ 60℃ (-49°F ~ 140°F) |
| Relative Humidity | 10%-90% RH |
| Password Type | 4 digit PIN code |
| Built-in Proximity Card Reader Frequency | ID type: 125KHz |
| Induction Card Identifying Type | ID type: EM |
| Card Reader Distance | 5~6 CM |
| Electric Locking Interface | Relay output or input of optional |
| Open Access | 1 |
| Door Sensor Interface | 1 |
| Add-in Reader Interface | 1 WG26 interface |
| Dimensions (L*W*H) | 110mm * 75mm * 25mm |
| Waterproof Rating | IP68 |
| Operating Speed | <20ms (with 2000 users) |

8. User Tips
- Convenient Access: With the T-AC04, there's no need to worry about forgetting or losing physical keys. Simply use your registered card or enter your PIN code for quick access.
- Night Visibility: The soft keyboard backlight makes it easy to locate and correctly enter your password even in complete darkness.
- Enhanced Security: Take advantage of the ability to reset your private password and quickly delete lost cards directly from the keypad to maintain high security.
- Power Supply: Ensure a stable 12VDC power supply for optimal performance.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact details provided with your purchase documentation or visit the official RETEKESS website. Keep your purchase receipt as proof of purchase.
10. Product Video
Watch this video for a visual overview of the RETEKESS T-AC04, highlighting its features and functionality.