1. Introduction
The SINOTIMER TM617 is an advanced electronic digital timer switch designed for precise control of electrical appliances and circuits. Featuring a 7-day weekly programmable schedule and up to 28 ON/OFF programs, this timer provides reliable and energy-efficient automation for various applications. Its compact design and clear digital display make it suitable for both residential and industrial use.

2. Key Features
- Digital Time Control: Electronic timer for accurate scheduling.
- Weekly Programming: Supports 7-day weekly programming.
- Multiple Programs: Up to 28 ON/OFF programs for flexible scheduling.
- Manual Control: Manual ON/AUTO/OFF modes for immediate control.
- Built-in Battery: Includes a backup battery to retain settings during power outages.
- Compact Design: Mini type with standard dimensions for easy integration.
- High Load Capacity: Max. current of 16A, suitable for various loads.
- Certifications: CE, ROHS, EMC, LVD certified for safety and quality.
3. Specifications
| Attribute | Value |
|---|---|
| Model Number | TM617 |
| Brand Name | SINOTIMER |
| Theory | Electronic |
| Use | Timer Switch |
| Type | Mini |
| Power Supply | 110V AC, 220~240V AC |
| Output | 1 NO + 1 NC |
| Max. Current of Output Load | 16A |
| Programs | 28 ON/OFF |
| Mini Interval | 1 minute |
| Max Interval | 7 days |
| Dimensions | 72*72*48mm |
| Battery Included | Yes (Backup) |
| Certification | CE, ROHS, EMC, LVD |
| Package Weight | 0.18 kg |
| Package Dimensions | 8 x 8 x 5 cm |
4. Package Contents
Upon opening your package, please ensure all items are present and in good condition:
- 1 x TM617 Electronic Digital Timer Switch
- 2 x Mounting Screws
- 1 x Instruction Manual (this document)

5. Safety Information
WARNING: Risk of electric shock. Installation should only be performed by a qualified electrician or trained personnel.
- Always disconnect power at the circuit breaker before installing or servicing the timer switch.
- Ensure the power supply voltage matches the timer's specifications (110V AC or 220-240V AC).
- Do not exceed the maximum current load of 16A.
- Keep the device away from water and excessive moisture.
- Do not attempt to open or repair the device yourself. Refer to qualified service personnel.
6. Installation
The TM617 timer switch is designed for panel mounting or surface mounting using the provided screws. Follow the wiring diagram carefully.
6.1 Wiring Connections
Refer to the diagram below for proper wiring. Ensure all connections are secure.

- L: Live (Phase) input.
- N: Neutral input.
- 1 & 2: Power supply for the timer module (connect to L and N).
- 3: Common terminal for the relay output.
- 4: Normally Open (NO) contact. Connect your load's live wire here if you want it to turn ON when the timer activates.
- 5: Normally Closed (NC) contact. Connect your load's live wire here if you want it to turn OFF when the timer activates.
6.2 Mounting
The timer can be mounted using the two screw holes on the front panel. The dimensions are 72x72x48mm.
7. Initial Setup and Programming
After installation and power-up, the timer display will activate. The internal backup battery ensures settings are retained even if main power is lost.
7.1 Setting Current Time and Day
- Press the 'C/R' button to clear any previous settings or reset the timer.
- Press and hold the 'Clock' button (usually marked with a clock icon).
- While holding 'Clock', press 'D+' to set the current day of the week (MO, TU, WE, TH, FR, SA, SU).
- While holding 'Clock', press 'H+' to set the current hour.
- While holding 'Clock', press 'M+' to set the current minute.
- Release the 'Clock' button to save the current time.
7.2 Programming ON/OFF Events
The TM617 supports up to 28 ON/OFF programs. Follow these steps to set your desired schedules:
- Press the 'P' button to enter programming mode. The display will show '1 ON'.
- Press 'D+' to select the day(s) for this 'ON' event. You can choose individual days, weekdays, weekends, or all days.
- Press 'H+' to set the hour for the 'ON' event.
- Press 'M+' to set the minute for the 'ON' event.
- Press 'P' again. The display will show '1 OFF'.
- Repeat steps 2-4 to set the day(s), hour, and minute for the corresponding 'OFF' event.
- Continue pressing 'P' to cycle through and set additional ON/OFF programs (2 ON, 2 OFF, etc.) up to 28 programs.
- After setting all desired programs, press the 'Clock' button to exit programming mode and return to the current time display.
8. Operation
8.1 Manual ON/AUTO/OFF Modes
The timer allows for manual override of programmed settings. Press the 'Manual' button (often represented by a hand icon or a dedicated button near the display) to cycle through the following modes:
- ON: The output is continuously ON, overriding any programmed 'OFF' events.
- AUTO: The timer operates according to the programmed ON/OFF schedules. This is the standard operating mode.
- OFF: The output is continuously OFF, overriding any programmed 'ON' events.
The current mode (ON, AUTO, OFF) is typically indicated on the display.
9. User Tips
- Intuitive Programming: Many users find the TM617 very easy and intuitive to program, often without needing to consult the manual extensively. Experiment with the 'P' button to cycle through program slots.
- Backup Battery: The built-in backup battery is a great feature, ensuring your settings are saved even during power interruptions. No need to reprogram after a power cut.
- Quality Construction: The timer is noted for its robust internal build quality.
10. Maintenance
- Cleaning: Wipe the exterior of the timer with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Battery: The internal backup battery is typically long-lasting and not user-replaceable. If the timer fails to retain settings after a power outage, the battery may need professional servicing.
- Inspection: Periodically check wiring connections for tightness and signs of wear or damage.
11. Troubleshooting
- Display is blank: Check power supply connections (L and N). Ensure the circuit breaker is ON.
- Programs not running: Ensure the timer is in 'AUTO' mode. Verify that the current time and day are set correctly. Double-check your programmed ON/OFF times and days.
- Load not switching: Check the wiring to your load (terminals 3, 4, 5). Ensure the load itself is functional. Verify the timer is in 'AUTO' mode and the program is active.
- Timer loses settings after power cut: The internal backup battery may be depleted. Contact support for assistance.
- Buttons unresponsive: Try pressing the 'C/R' button to reset the timer. If the issue persists, power cycle the device.
12. Warranty and Support
The SINOTIMER TM617 Electronic Digital Timer Switch comes with a standard manufacturer's warranty against defects in materials and workmanship. For warranty claims, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Please have your purchase information and product model number (TM617) ready when contacting support.