SHIMANO SM-PCE02-B3

Contents

SHIMANO SM-PCE02-B3 DI2 Diagnostic PC Linkage Device User Manual

Model: SM-PCE02-B3

1. Introduction

The SHIMANO SM-PCE02 PC Linkage Device is an essential tool for maintaining and customizing your SHIMANO DI2 and STEPS electronic shifting and drive systems. This device allows you to connect your bicycle's electronic components to a personal computer to perform various diagnostic and customization tasks.

Key functions include:

  • Checking system functions and connections.
  • Diagnosing and identifying errors within the system.
  • Updating firmware for improved performance and new features.
  • Customizing various functions of your DI2 or STEPS components.

The SM-PCE02 connects to your PC via a Micro USB port and is compatible with EW-SD50 and EW-SD300 cables for connecting to your bicycle's system.

SHIMANO SM-PCE02-B3 device, cables (EW-SD50, EW-SD300), and packaging.
Figure 1: SHIMANO SM-PCE02-B3 device, included cables (EW-SD50, EW-SD300), and retail packaging.
SHIMANO SM-PCE02-B3 retail packaging showing compatibility with EW-SD50 and EW-SD300.
Figure 2: Retail packaging for the SHIMANO SM-PCE02-B3, highlighting compatibility.

2. Setup

2.1 Package Contents

Verify that your package contains the following items:

  • SHIMANO SM-PCE02-B3 PC Linkage Device
  • Micro USB cable
  • EW-SD50 cable
  • EW-SD300 cable
Top view of the SHIMANO SM-PCE02-B3 device.
Figure 3: Top view of the SM-PCE02-B3 device.
Close-up of the SHIMANO SM-PCE02-B3 device with the SM-PCE02 label.
Figure 4: Close-up of the SM-PCE02 label on the device.

2.2 Software Installation

Before connecting the device, download and install the latest version of the SHIMANO E-Tube Project software from the official SHIMANO website. This software is required for the device to function correctly.

2.3 Connecting to PC

  1. Connect one end of the provided Micro USB cable to the Micro USB port on the SM-PCE02 device.
  2. Connect the other end of the Micro USB cable to an available USB port on your computer.
Side view of the SHIMANO SM-PCE02-B3 device showing the Micro USB port.
Figure 5: Side view of the SM-PCE02-B3 device, highlighting the Micro USB port.
Close-up of the Micro USB cable connectors.
Figure 6: Close-up of the Micro USB cable connectors.

2.4 Connecting to Bicycle System

Use the appropriate EW-SD50 or EW-SD300 cable to connect the SM-PCE02 device to your bicycle's DI2 or STEPS system. The connection point on your bicycle will vary depending on the specific components and setup (e.g., junction box, battery, or specific component port).

Close-up of the EW-SD50 cable connector.
Figure 7: Close-up of an EW-SD50 cable connector.

3. Operating Instructions

Once the SM-PCE02 is connected to both your PC and your bicycle, launch the SHIMANO E-Tube Project software.

3.1 System Recognition

The E-Tube Project software should automatically detect the connected SM-PCE02 device and the bicycle's electronic system. Follow any on-screen prompts to confirm the connection.

3.2 Main Functions

  • System Check: View the status of all connected components, battery level, and current firmware versions.
  • Error Diagnosis: Identify any error codes or malfunctions within the DI2/STEPS system. The software will often provide explanations and troubleshooting steps for detected errors.
  • Firmware Update: Download and install the latest firmware for your components. This is crucial for optimal performance and accessing new features. Always ensure a stable power supply during firmware updates.
  • Customization: Adjust various settings such as shift speed, button functions, multi-shift modes, and more, depending on your specific components.

Refer to the comprehensive help documentation within the SHIMANO E-Tube Project software for detailed instructions on each function and specific component settings.

4. Maintenance

  • Keep the SM-PCE02 device and cables clean and dry. Avoid exposure to moisture, dust, and extreme temperatures.
  • Store the device and cables in a protective manner to prevent physical damage, especially to the connectors.
  • Regularly check the Micro USB port and cable connectors for any signs of wear or damage.
  • Ensure the E-Tube Project software is always updated to its latest version to ensure compatibility and access to the newest features and bug fixes.

5. Troubleshooting

5.1 Device Not Recognized by PC

  • Ensure the Micro USB cable is securely connected to both the SM-PCE02 and the PC.
  • Try a different USB port on your computer.
  • Verify that the SHIMANO E-Tube Project software is correctly installed and up-to-date.
  • Restart your computer and try again.

5.2 Bicycle System Not Detected

  • Check that the EW-SD50 or EW-SD300 cable is firmly connected between the SM-PCE02 and the bicycle's system.
  • Ensure the bicycle's battery is charged and the system is powered on (if applicable).
  • Inspect the cables for any visible damage.
  • Consult the E-Tube Project software's help section for specific connection diagrams for your bicycle's components.

5.3 Firmware Update Failure

  • Do not disconnect the device or power off the PC/bicycle during an update.
  • Ensure a stable power supply for both the PC and the bicycle's DI2/STEPS system.
  • If an update fails, try restarting the process. If issues persist, refer to the E-Tube Project software's troubleshooting guide or contact SHIMANO support.

6. Specifications

Feature Specification
Model Number SM-PCE02-B3
Brand SHIMANO
Type PC Linkage Device
PC Connectivity Micro USB Port
System Compatibility SHIMANO DI2, SHIMANO STEPS
Cable Compatibility EW-SD50, EW-SD300
Origin Japan
Package Length 15 cm
Package Width 10 cm
Package Height 4 cm
Package Weight 0.24 kg

7. User Tips

  • Verify Authenticity: Ensure you purchase genuine SHIMANO products for reliable performance and compatibility. Users have reported satisfaction with the authenticity of this product.
  • Check Included Cables: The SM-PCE02 typically comes with both EW-SD50 and EW-SD300 cables. Confirm these are present upon receipt.
  • Understand Model Differences: Be aware that there might be different versions (e.g., PCE01 vs. PCE02). Ensure you are using the correct device and software version for your specific needs.
  • Regular Firmware Updates: Keep your DI2/STEPS components updated with the latest firmware via the E-Tube Project software to benefit from performance improvements and new features.

8. Warranty and Support

The SHIMANO SM-PCE02-B3 is covered by SHIMANO's standard manufacturer warranty. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official SHIMANO website.

For technical support, troubleshooting assistance beyond this manual, or warranty claims, please contact your authorized SHIMANO dealer or SHIMANO customer service directly.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.