1. Product Introduction
The HLTNC series stepper/closed-loop servo motor is a high-precision positioning motor designed for automatic control systems. The stepper motor converts electrical pulse signals into precise angular displacement or linear motion, featuring simple structure, low cost, and reliable operation—ideal for general-precision applications. The closed-loop servo motor integrates a stepper motor with a high-resolution encoder (1000-2500 PPR), enabling real-time position feedback and error correction, which significantly improves positioning accuracy, dynamic response, and load capacity while eliminating step loss. Both motors are compatible with most stepper drivers (e.g., TB6600, DM542) and CNC systems (Grbl, Mach3), suitable for 3D printing, CNC machining, robotic arms, and other precision motion control scenarios.
2. Core Technical Parameters
General Specifications
| Item | Specification (Stepper Motor) | Specification (Closed-Loop Motor) |
|---|---|---|
| Phase Configuration | Bipolar (2-Phase) | Bipolar (2-Phase) with Encoder |
| Step Angle | 1.8° (200 Steps/Revolution) | 1.8° (200 Steps/Revolution) |
| Micro-Stepping Support | Up to 1/64 Micro-Step (Driver-Dependent) | Up to 1/128 Micro-Step (Driver-Dependent) |
| Holding Torque | 0.3N•m - 4.5N•m (NEMA 17/23/34) | 0.5N•m - 6.0N•m (NEMA 17/23/34) |
| Rated Current | 1.0A - 3.0A/Phase | 1.2A - 3.5A/Phase |
| Rated Voltage | 2.8V - 4.2V (Phase Voltage) | 2.8V - 4.2V (Phase Voltage) |
| Encoder Resolution (Closed-Loop) | — | 1000/2000/2500 PPR (Optional) |
| Rotor Inertia | 10g•cm² - 200g•cm² | 12g•cm² - 220g•cm² |
| Protection Grade | IP40 (Dustproof) | IP40 (Dustproof) |
| Insulation Class | B Class | B Class |
| Operating Temperature | -10°C ~ +50°C | -10°C ~ +50°C |
| Storage Temperature | -20°C ~ +70°C | -20°C ~ +70°C |
| Shaft Diameter | 5mm/8mm/10mm (Optional) | 5mm/8mm/10mm (Optional) |
| Frame Size (NEMA) | NEMA 17/NEMA 23/NEMA 34 | NEMA 17/NEMA 23/NEMA 34 |
| Weight | 0.2KG - 3.0KG | 0.3KG - 3.5KG |
Nema23 57HS76 Stepper Motor Specifications
| Specifications | |
|---|---|
| Step Angle | 1.8°±5% |
| Current | 3.0A |
| Phase No. | 2 |
| Resistance | 1.3±10%Ω |
| Insulation Resistance | 100MOhm(500V DC) |
| Inductance | 6.5±20%mH |
| Insulation Class | B |
| Holding Torque | 30kg.cm (3Nm) |
Microstep Driver TB6600 Specifications
| Specifications | |
|---|---|
| Name | TB6600 Stepper Motor Driver |
| Voltage | 9-42VDC |
| Current | 0.5-3.5A |
| Microstep | 1-32 |
350W 36V Power Supply Specifications
| Specifications | |
|---|---|
| Type | S-350-36 |
| Voltage DC | 36V |
| Rated Current | 9.7A |
| Current Range | 0-9.7A |
| Rated Power | 349.2W |
| Ripple and Noise | 240mVp-p |
| Voltage Adjustment Range | 32-40V |
| Voltage Accuracy | ± 1.0% |
| Linear Adjustment Rate | ± 0.5% |
| Load Adjustment Rate | ± 0.5% |
| Start-up and Rise Time | 200ms 50ms |
| Retention Time | 20ms |
3. Product Structure Breakdown
3.1 Common Components
- Motor Body: Aluminum alloy frame (heat dissipation fins)
- Rotor Shaft: High-precision steel shaft (hardened treatment)
- Stator Windings: Copper windings (insulated with heat-resistant material)
- End Caps: Front/rear plastic/metal caps with bearings
- Mounting Holes: Standard NEMA bolt pattern (compatible with most brackets)
- Terminal Block: 4/6-pin connector for power/signal wires
3.2 Closed-Loop Motor Exclusive Components
- Encoder: High-resolution optical encoder (integrated at rear end)
- Encoder Cable: Shielded cable for position feedback (1.5m standard)
- Encoder Connector: 6-pin JST/DB9 connector (compatible with closed-loop drivers)
3.3 Optional Accessories
- Stepper/Closed-Loop Motor: Mounting Bracket, Coupling, Heat Sink
- Closed-Loop Motor: Encoder Extension Cable (3m/5m), Connector Adapter
4. Installation Steps
4.1 Pre-Installation Preparation
- Confirm the motor model (stepper/closed-loop) and frame size (NEMA) matches the equipment's mounting requirements.
- Verify the motor's rated current/voltage is compatible with the stepper driver (avoid overcurrent damage).
- Prepare tools: Screwdriver set, torque wrench, multimeter, wire stripper, coupling (for shaft connection).
- For closed-loop motor: Check the encoder cable for damage (no cuts or exposed wires).
4.2 Mechanical Installation
- Clean the motor mounting surface and remove oil, dust, or debris.
- Align the motor's mounting holes with the equipment's bracket and secure with bolts (torque: 4-8 N-m, depending on frame size).
- Connect the motor shaft to the load (e.g., lead screw, gear) using a coupling:
- Ensure coaxiality (radial deviation ≤0.1mm) to avoid vibration or bearing wear.
- Tighten the coupling screws evenly (do not over-tighten to prevent shaft deformation).
- For NEMA 23/34 motors: Install a heat sink (optional) on the motor body to improve heat dissipation during long-term operation.
4.3 Electrical Wiring
Important: Turn off the power supply of the driver/CNC system for safety before proceeding with any wiring.
4.3.1 Stepper Motor (Bipolar 2-Phase)
- Identify the motor's phase wires (typically labeled A+, A-, B+, B-; refer to the wiring diagram):
- Connect A+ → Driver's Phase A Positive Terminal
- Connect A- → Driver's Phase A Negative Terminal
- Connect B+ → Driver's Phase B Positive Terminal
- Connect B- → Driver's Phase B Negative Terminal
- Ensure wire connections are tight and insulated (use insulating tape for exposed wires).
- Double-check for wrong connections (e.g., A+ to B+) to avoid motor burnout.
4.3.2 Closed-Loop Motor (Stepper + Encoder)
- Complete the stepper motor phase wiring as per Section 4.3.1.
- Connect the encoder cable to the motor's encoder connector and the driver's encoder interface:
- Encoder VCC (5V) → Driver's Encoder Power Positive
- Encoder GND → Driver's Encoder Power Negative
- Encoder A → Driver's Encoder Signal A
- Encoder B → Driver's Encoder Signal B
- Encoder Z (Zero Pulse, Optional) → Driver's Encoder Signal Z
- Secure the encoder cable with cable ties (keep it away from power wires to avoid electromagnetic interference).
4.4 Post-Installation Test
- Power on the driver/CNC system and set the driver's current limit to match the motor's rated current (e.g., 2.0A for a 2.0A/phase motor).
- Test manual jog: Use the CNC system to move the motor forward/backward at low speed (e.g., 100 steps/s):
- Check for smooth movement (no jitter, noise, or step loss).
- For closed-loop motor: Confirm the driver's encoder feedback indicator is active.
- Test positioning accuracy: Send a fixed number of pulses (e.g., 200 steps = 1 full rotation) and verify the motor rotates to the correct position.
- Run the motor at rated speed for 30 minutes: Monitor the motor temperature (≤70°C) and check for abnormal heat or noise.
4.5 Mach3 Software Installation Procedure
The Mach3 software and plugin files are typically provided via email or download links. If you did not receive a CD, please contact the seller for the latest files.
Download links (Google Drive):
- Mach3 software: https://drive.google.com/file/d/1yoa7EdBHP0LmFZDceVldNOOF81X0rGR6/view?usp=drive_link
- Mach3 plugin: https://drive.google.com/file/d/1LKaYwL6L5c0NTqYJEwmiFuc5mnzHAttP/view?usp=drive_link
- Open the downloaded files and click on the 'Mach3 software' folder.
Figure 7: Step 1 - Click 'Mach3 software' folder. - Locate and run the Mach3 installer (e.g., 'Mach3VersionR3.041instal').
Figure 8: Step 2 - Run the Mach3 installer. - Follow the on-screen prompts. Click 'Next' on the welcome screen.
Figure 9: Step 3 - Mach3 setup welcome. - Accept the End User License Agreement by clicking 'Yes'.
Figure 10: Step 4 - Accept license agreement. - Click 'Next' on the Readme Information screen.
- Select the destination directory for Mach3 (default is usually fine), then click 'Next'.
Figure 11: Step 6 - Select destination directory. - Select the program folder (default is usually fine), then click 'Next'.
Figure 12: Step 7 - Select program folder. - Click 'Next' to start copying files.
Figure 13: Step 8 - Start copying files. - If prompted to register components, click 'OK' or 'Yes'.
- Click 'Finish' to complete the setup.
Figure 14: Step 10 - Setup finished. - After Mach3 installation, navigate to the 'Mach3Plugin' folder provided with your files.
Figure 15: Step 11 - Open 'Mach3Plugin' folder. - Copy the 'BL-UsbMach.dll' and 'RnRMotion.dll' files from the plugin folder.
Figure 16: Step 12 - Copy plugin files. - Paste these files into the 'Plugins' folder within your Mach3 installation directory (e.g., C:\Mach3\Plugins).
Figure 17: Step 13 - Navigate to Mach3 installation directory. - Open the Mach3 application from your desktop shortcut (e.g., 'Mach3Mill').
Figure 18: Step 14 - Open Mach3 application. - The Mach3 CNC Controller interface should now be ready for use.
Figure 19: Mach3 CNC Controller interface.
Video 1: Unboxing and physical wiring test of the HLTNC 4 Axis Kit.
5. Operation Instructions
5.1 Basic Operation
- Power On Sequence: Turn on the driver power → Start the CNC/control system → Send motion commands.
- Speed Adjustment: Adjust the pulse frequency via the control system (max speed depends on motor torque and driver capacity; avoid exceeding 3000 rpm for NEMA 17 motors).
- Micro-Stepping Setting: Configure micro-stepping (e.g., 1/16, 1/32) on the driver to improve positioning smoothness (higher micro-stepping = smoother motion but lower maximum speed).
- Power Off Sequence: Stop all motor motion → Turn off the CNC/control system → Turn off the driver power.
5.2 Closed-Loop Motor Exclusive Operations
- Error Correction: If step loss occurs (e.g., load exceeds torque), the driver will automatically correct the position via encoder feedback—no manual reset required.
- Alarm Handling: If the driver displays an encoder alarm (e.g., no feedback), check the encoder wiring or replace the encoder cable.
5.3 Load Operation Guidelines
- Avoid overloading the motor (do not exceed the holding torque) to prevent step loss (stepper) or driver alarm (closed-loop).
- For high-speed operation (≥1500 rpm), use a driver with high-voltage input (e.g., 24V-48V) to maintain torque.
- For continuous operation (≥24 hours), reduce the driver's current limit by 10-20% to reduce heat generation.
- Do not reverse the motor direction abruptly at high speed (allow deceleration to low speed first).
6. Maintenance and Care
6.1 Daily Maintenance
- Clean the motor surface and heat dissipation fins daily to remove dust (use a soft brush or compressed air).
- Check the motor shaft for wear or corrosion (apply anti-rust oil as necessary).
- Inspect wire connections and encoder cable (closed-loop) for looseness or damage.
6.2 Regular Maintenance (Every 6 Months)
- Check the motor bearings for smooth rotation (replace bearings if there is noise or resistance).
- Tighten the mounting bolts and coupling screws (vibration may cause loosening).
- For closed-loop motor: Clean the encoder lens with a dry cloth (avoid touching with fingers).
- Test the motor's holding torque and positioning accuracy (calibrate via the control system if deviations occur).
6.3 Long-Term Storage (≥1 Month)
- Disconnect all power and signal wires.
- Clean the motor surface and apply anti-rust oil to the shaft.
- Store the motor in a dry, well-ventilated environment (humidity ≤60%, temperature 0°C ~ +30°C).
- For stepper motors: Apply a small current (50% of rated current) to the windings every 3 months to prevent demagnetization (optional).
7. Important Safety Notes
- Ensure the motor is properly grounded to prevent electric shock and electromagnetic interference.
- Do not touch the rotating motor shaft or coupling during operation (risk of injury).
- Wear protective gloves and goggles when installing or maintaining the motor.
- Do not disassemble the motor or encoder (closed-loop) without authorization—this will void the warranty and damage internal components.
- Do not exceed the rated current, voltage, or speed to prevent motor burnout or encoder failure.
- Disconnect the power supply before wiring, maintenance, or replacing parts.
- Keep the motor away from water, oil, high temperature, or corrosive environments.
8. Common Faults and Troubleshooting
| Fault Phenomenon | Possible Causes | Troubleshooting Methods |
|---|---|---|
| Motor Fails to Rotate | 1. Power supply disconnected; 2. Wrong wiring; 3. Driver not powered on | 1. Check power connection; 2. Recheck phase/encoder wiring; 3. Verify driver power |
| Step Loss (Stepper Motor) | 1. Overload; 2. Low driver current; 3. High speed | 1. Reduce load; 2. Increase driver current (match rated value); 3. Lower speed or use micro-stepping |
| Position Deviation (Closed-Loop) | 1. Encoder wiring error; 2. Encoder damaged; 3. Coupling slip | 1. Recheck encoder connections; 2. Replace encoder; 3. Tighten coupling screws |
| Motor Overheats | 1. Driver current too high; 2. Poor ventilation; 3. Continuous overload | 1. Reduce driver current; 2. Improve ventilation or add heat sink; 3. Reduce load |
| Abnormal Noise/Vibration | 1. Coaxiality error; 2. Loose bolts; 3. Bearing wear | 1. Realign motor and load; 2. Tighten bolts; 3. Replace bearings |
| Encoder Alarm (Closed-Loop) | 1. Encoder cable damage; 2. Encoder power failure; 3. Lens dirty | 1. Replace encoder cable; 2. Check encoder 5V power; 3. Clean encoder lens |
9. Packaging List
- Stepper/Closed-Loop Servo Motor ×1
- Phase Wiring Cable (1.5m) ×1
- Encoder Cable (1.5m, Closed-Loop Only) ×1
- Mounting Bolts x4
- Wiring Diagram ×1
- User Manual (This Document) ×1
- Optional: Mounting Bracket x1, Coupling x1, Heat Sink x1
10. User Tips
- Shaft Diameter: When selecting motor options, "8mm dual" means the motor shaft extends from both sides, while "8mm single" means it extends from only one side.
- Controller Power: The controller board requires 12V to 24V. This voltage is primarily for inputs and outputs. The drivers themselves can operate from USB power. If needed, a converter can be used to adjust the voltage.
11. Warranty and Support
- Warranty Period: 12 months warranty against non-human damage (encoder: 6 months warranty for closed-loop motor).
- Warranty Exclusions: Damage caused by improper installation, wrong wiring, overcurrent/overvoltage, disassembly, misuse, or natural disasters.
- Technical Support: For wiring, driver configuration, or performance issues, contact our technical team with the product model and fault description.
- Replacement Parts: Original replacement parts (bearings, encoder, cables) are available for purchase.
Version: V1.0
Applicable Models: HLTNC NEMA 17/23/34 Stepper Motor Series / HLTNC NEMA 17/23/34 Closed-Loop Servo Motor Series
Date: [Leave Blank for Customization]
12. Additional Resources
A PDF version of the user manual is available for download: