1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the GEYA THC Series Weekly Programmable Digital Timer Switch. This device is designed for DIN rail mounting and features an LCD display for easy programming of ON/OFF times over a weekly cycle. It is suitable for controlling various electrical appliances and circuits.


2. Specifications
| Feature | Specification |
|---|---|
| Brand Name | GEYA |
| Model Number | THC-15A, THC-20A, THC-30A |
| Product Name | Weekly Timer Switch |
| Type | Mini Digital Timer |
| Theory | Digital |
| Use | Timer Switch |
| Rated Voltage | AC220V-240V |
| Rated Frequency | 50/60Hz |
| Rated Current | 16A (THC-15A), 20A (THC-20A), 30A (THC-30A) |
| Display | LCD |
| Switching Contact | 1 Changeover Switch (THC-15A, THC-20A), 1 NO (THC-30A) |
| Mounted | Din Rail |
| Battery Included | Yes |
| Certification | CE |
| Origin | Mainland China |

3. Safety Information
Please read and understand all safety instructions before installing or operating this device. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Installation should only be performed by a qualified electrician.
- Ensure power is disconnected at the main circuit breaker before any installation or wiring work.
- Do not exceed the specified current and voltage ratings of the device.
- This device is designed for indoor use only.
- Keep away from water and high humidity environments.
- Do not attempt to open or repair the device yourself. Refer to qualified service personnel.
4. Package Contents
Upon opening the package, verify that you have received the following items:
- GEYA THC Series Digital Timer Switch (1 unit)
- User Manual (this document)
5. Setup and Installation
5.1 Mounting
The GEYA THC Series timer switch is designed for DIN rail mounting. Simply clip the device onto a standard 35mm DIN rail in your electrical panel.

5.2 Wiring
WARNING: Ensure power is OFF before wiring. Incorrect wiring can cause damage to the device or electrical shock.
Refer to the wiring diagram below for proper connection. The timer requires a 220V-240V AC power supply. Connect the Line (L) and Neutral (N) wires to terminals 1 and 2 respectively. The load should be connected to terminals 3, 4, and 5 depending on the model and desired contact configuration.

- Terminals 1 & 2: Power input (N and L for AC220V-240V).
- Terminals 3, 4, 5: Load connections.
- For THC-15A and THC-20A (1 Changeover Switch): Typically, 3 is Common, 4 is Normally Open (NO), 5 is Normally Closed (NC).
- For THC-30A (1 NO): Typically, 3 is Common, 4 is Normally Open (NO).
After wiring, restore power and proceed to the operating instructions.
6. Operating Instructions
The GEYA THC timer switch features an LCD display and several buttons for programming. The buttons are typically labeled P (Program), D+ (Day), H+ (Hour), M+ (Minute), Reset, and Manual.

6.1 Initial Time Adjustment
- Press the 'P' button to enter the timing setting mode.
- Use 'H+' to adjust the hour.
- Use 'M+' to adjust the minute.
- Use 'D+' to adjust the day of the week.
- Once the current time and day are set, press 'P' again to exit or wait for the display to return to normal.
6.2 Setting ON/OFF Programs
The timer allows for multiple ON/OFF programs. Follow these steps for each program:
- Press the 'P' button to enter the timing setting. The display will show "1 ON" (indicating the first ON time of the first program).
- Press 'H+' and 'M+' to set the desired ON time.
- Press 'D+' to select the day(s) of the week for this ON program. You can choose individual days, weekdays, weekends, or all days.
- Press 'P' again. The display will show "1 OFF" (indicating the first OFF time of the first program).
- Press 'H+' and 'M+' to set the desired OFF time.
- Press 'D+' to select the day(s) of the week for this OFF program.
- Repeat steps 1-6 for additional ON/OFF programs (e.g., "2 ON", "2 OFF", etc.).
- After setting all desired programs, press the 'P' button repeatedly until the display returns to the current time or press the 'Reset' button to exit programming mode.
6.3 Running the Program
After setting your programs, ensure the timer is in "AUTO" mode for the programs to execute automatically. Press the "MANUAL" button to cycle through modes: ON, AUTO, OFF. Select "AUTO" for automatic operation.
6.4 Manual Override
The "MANUAL" button also allows for temporary manual override:
- Pressing "MANUAL" once may switch the output from AUTO to ON or OFF, depending on the current state.
- Pressing it again will cycle through the modes (ON, AUTO, OFF).
- To return to automatic operation, ensure the display shows "AUTO".
6.5 Reset Function
To clear all programs and reset the timer to its default state, press the 'RESET' button (usually a small recessed button that requires a pointed object like a pen to press).
7. Maintenance
- Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Battery: The device includes an internal battery to retain settings during power outages. This battery is typically long-lasting and not user-replaceable. If the display goes blank or settings are lost frequently, the battery may need professional servicing.
- Inspection: Periodically check the wiring connections to ensure they are secure and free from corrosion.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on / LCD is blank. | No power supply; incorrect wiring; internal battery depleted (if no mains power). |
|
| Programs are not executing / Load does not switch ON/OFF. | Timer is not in "AUTO" mode; incorrect program settings; faulty wiring to load; defective relay. |
|
| Settings are lost after power outage. | Internal battery is depleted or faulty. |
|
| Relay does not activate (no click, no power to load). | Defective relay; incorrect wiring; load current exceeds rating. |
|
9. User Tips
- Ease of Use: Many users find this timer easy to program once familiar with the button functions. Take your time to understand each button's role.
- Reliability: The product is generally considered reliable and durable, with some users reporting perfect operation for over a year.
- Programming Flexibility: The weekly programmable feature allows for versatile scheduling of various devices.
- Power-Up: If the device has been unpowered for a long time, allow it to be connected to mains power for a few hours to ensure the internal battery is charged and retains settings.
10. Frequently Asked Questions (FAQ)
- Q: Which brand manufactures this timer?
- A: This timer is manufactured by the brand GEYA.
- Q: Can the digital timer be programmed to turn on for a few minutes, then off for a few minutes, repeating this continuously?
- A: Yes, the timer allows for multiple ON/OFF programs. You can set specific ON and OFF times for each program, and these can be repeated daily or on selected days of the week. For very short, continuous cycling (e.g., every few minutes), you would need to program multiple ON/OFF pairs. Consult the "Setting ON/OFF Programs" section for details.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.