HoldPeak HP-770M

Contents

HoldPeak HP-770M Digital Multimeter User Manual

Model: HP-770M

Brand: HoldPeak

1. Overview

The HoldPeak HP-770M Digital Multimeter is a compact, portable, and stable device with anti-dropping capabilities. It features a 6000-count LCD monitor with 25mm high characters for clear readings. The overall circuitry design incorporates large-scale IC A/D converters and overload protection, ensuring excellent performance and making it a practical utility instrument.

This multimeter can measure DC & AC voltage, DC & AC current, resistance, capacitance, frequency, duty cycle, temperature, transistor hFE, Non-Contact AC Voltage (NCV) detection, positive diode voltage fall, and audible continuity.

2. Product Features and Panel Layout

The HP-770M Digital Multimeter offers a wide range of functions and a user-friendly interface. Key features include:

  • High-Resolution LCD Display: Clearly readable with intelligent backlight for dark environments.
  • Auto Range Function: Automatically selects the appropriate measurement range.
  • True RMS: Provides accurate measurements for non-sinusoidal AC waveforms.
  • Mechanical Blocking System: Prevents incorrect test lead insertion by covering unused ports when the rotary switch is set to a specific function.
  • Auto Power Off: Conserves battery life by automatically turning off after 15 minutes of inactivity.
  • Data Hold: Freezes the current reading on the display.
  • NCV (Non-Contact AC Voltage) Detection: Safely detects AC voltage without direct contact.
  • Temperature Measurement: Measures temperature using the included probe.
  • Diode Test & Continuity Buzzer: For testing diodes and circuit continuity.
  • Transistor hFE Test: For testing transistor gain.
  • Bar Graph Display: Provides an analog-style representation of readings.
  • 180° Rotating Stand: For convenient viewing angles.
Detailed panel layout of the HoldPeak HP-770M Digital Multimeter with numbered components.

Figure 1: Detailed Panel Layout of HP-770M Multimeter

Panel Components:

  1. NCV detection area: Non Contact AC Voltage (NCV) detection area.
  2. CDS sensor: Reacts to ambient brightness to automatically control LCD backlight.
  3. NCV red light: Indicates Non Contact AC Voltage (NCV) detection.
  4. NCV green light: Indicates Non Contact AC Voltage (NCV) detection.
  5. LCD display: 6000 counts digit, full function symbol display.
  6. POWER key: Press to power on or off the meter.
  7. RELA Key: Enters relative measuring mode.
  8. SELECT/HOLD key: Selects between functions (e.g., diode/continuity, °C/°F, Hz/Duty) or locks the display value.
  9. Rotary Switch: Used to select functions and ranges.
  10. FUSED 20A MAX: 20A Input Jack.
  11. FUSED 800mA MAX: mA Input Jack and Temperature '+' Input Jack.
  12. VΩHz: V/Hz Input Jack.
  13. COM T-: Common and Temperature '-' Input Jack.
  14. Transistor hFE test Input Jack: For transistor testing.
  15. Crust of meter: The outer casing.
  16. Protective casing: Provides protection for the device.
Overview of HoldPeak HP-770M features including AC/DC Voltage, Current, Resistance, Capacitance, Temperature, Frequency, Duty Cycle, NCV, Auto Back-Light, Auto Power Off, Function Switch Indicator Lamp, Mechanical Blocking System, MAX/MIN, and 180° Rotating Stand.

Figure 2: HP-770M Feature Overview

Illustration showing the Auto Range and Manual Range functions of the multimeter.

Figure 3: Auto Range and Manual Range Functions

3. Safety Information

The meter is designed according to IEC-1010 standards for electronic measuring instruments with an over-voltage category 1000V (CAT III) and pollution degree 2. Always follow all safety and operating instructions to ensure safe and proper use of the meter.

Safety Symbols:

  • Dangerous voltage may be present.
  • Double insulation (protection Class II).
  • Important safety information, refer to the operating manual.

4. Special Cautions for Operation

  • The multimeter should only be used with the supplied test leads. Replace damaged test leads only with the same model or electric specifications.
  • To avoid electric shock, do not use the meter before the cover is in place.
  • The range switch should be in the correct position for the measurement.
  • To avoid electric shock and damaging the instruments, the input signals are forbidden to exceed the specified limits.
  • When measuring TV sets or switched power supplies, pay attention to possible pulses that may damage the circuit.
  • The range switch position must not be changed randomly during measurement.
  • Take caution against shock when measuring voltage higher than DC 60V & AC 30V.
  • Protection fuses should only be replaced with the same type and specification.
  • After operation, set the function switch to OFF to save battery power.
  • If the meter is not used for a long time, remove the battery to avoid damage from leakage.

5. General Specifications

  • Max Voltage between input terminal and Earth Ground: CAT III 1000V
  • Over-range Indication: Display "OL" for the significant digit.
  • Automatic display of negative polarity: "-"
  • Low Battery Indication: Battery symbol displayed.
  • Max LCD display: 6000 counts digit.
  • Auto range & Manual range control.
  • Auto Power Off: After 15 minutes of inactivity.
  • Operating Temperature: 0°C to 40°C (relative humidity <85%).
  • Storage Temperature: -10°C to 50°C (relative humidity <85%).
  • Guaranteed precision Temperature: 23°C ± 5°C (relative humidity <70%).
  • Dimensions: 195 x 88 x 40mm.
  • Weight: Approx. 350g (including battery).

6. Testing Specifications

Accuracy is specified for a period of one year after calibration and at 18°C to 28°C (64°F to 82°F) with relative humidity up to 70%.

6.1 DC Voltage

RangeResolutionAccuracy
600mV0.1mV±(0.5% of rdg + 2 digits)
6V1mV
60V10mV
600V100mV
1000V1V±(0.8% of rdg + 2 digits)

Impedance: 10MΩ. Overload protection: 1000V DC or 750V AC rms.

6.2 AC Voltage (True RMS)

RangeResolutionAccuracy
6V1mV±(1.0% of rdg + 3 digits)
60V10mV
600V100mV±(1.5% of rdg + 3 digits)
750V1V

Impedance: 10MΩ. Overload protection: 1000V DC or 750V AC rms. Frequency Range: 40 to 2kHz.

6.3 DC Current

RangeResolutionAccuracy
60µA0.01µA±(1.2% of rdg + 2 digits)
600µA0.1µA
6mA1µA
60mA10µA
600mA100µA±(2.0% of rdg + 3 digits)
20A10mA±(2.5% of rdg + 3 digits)

Overload protection: 800mA/250V Fast Fuse, 20A/250V Fast Fuse, 20A up to 15 seconds.

6.4 AC Current (True RMS)

RangeResolutionAccuracy
6mA1µA±(1.5% of rdg + 3 digits)
600mA100µA
20A10mA±(2.5% of rdg + 5 digits)

Overload protection: 800mA/250V Fast Fuse, 20A/250V Fast Fuse, 20A up to 15 seconds. Frequency Range: 40 to 2kHz.

6.5 Resistance

RangeResolutionAccuracy
600Ω0.1Ω±(1.0% of rdg + 3 digits)
6kΩ1Ω±(1.0% of rdg + 2 digits)
60kΩ10Ω
600kΩ100Ω
6MΩ1kΩ±(1.5% of rdg + 3 digits)
60MΩ10kΩ

Overload protection: 250V DC or AC rms.

6.6 Capacitance (Auto Range)

RangeResolutionAccuracy
9.999nF1pF±(3.0% of rdg + 10 digits)
99.99nF10pF±(2.5% of rdg + 5 digits)
999.9nF100pF
9.999µF1nF
99.99µF10nF±(5.0% of rdg + 10 digits)
999.9µF100nF±(10.0% of rdg + 20 digits)
9.999mF1µF
99.99mF10µF

Overload protection: 800mA/250V Fast Fuse.

6.7 Frequency (Auto Range)

RangeResolutionAccuracy
9.999Hz0.001Hz±(0.1% of rdg + 5 digits)
99.99Hz0.01Hz
999.9Hz0.1Hz
9.999kHz1Hz
99.99kHz10Hz
999.9kHz100Hz
9.999MHz1kHz

Sensitivity: sine wave 0.6V rms (9.999MHz: 1.5V rms). Overload protection: 250V DC or AC rms.

6.8 Duty Cycle

Range: 0.1%~99.9%. Accuracy: ±(2.0% of rdg + 2 digits), Frequency lower than 10kHz. Sensitivity: sine wave 0.6V rms. Overload protection: 250V DC or AC rms.

6.9 Temperature

RangeResolutionAccuracy
-20~150°C1°C±(3°C + 1 digit)
151~1000°C1°C±(3% of rdg + 2 digits)
-4~302°F1°F±(5°F + 2 digits)
303~1832°F1°F±(3% of rdg + 3 digits)

NiCr-NiSi K-type sensor. Overload protection: 800mA/250V Fast Fuse.

6.10 Diode and Audible Continuity Test

Diode Test: Displays approximately forward voltage of diode (approx. 1.5mA forward DC current, approx. 4V reversed DC voltage). Continuity Test: Built-in buzzer sounds if resistance is less than 50Ω (approx. 2V open circuit voltage). Overload protection: 250V DC or AC rms.

6.11 Transistor hFE Test

Test range: 0-1000. Ib=10µA, Vce=1.8V Approx.

6.12 Non Contact AC Voltage (NCV) Detection

Test voltage range: 90V~1000V AC rms. The NCV red light and green light will light up alternately with sound.

7. Operating Instructions

7.1 Attention Before Operation

  • Check battery: If the battery voltage drops below the proper operating range, the battery symbol will appear on the LCD, indicating the battery needs to be changed.
  • Pay attention to the input jack markings (e.g., mA, A, VΩHz) to ensure the input voltage or current is within specified limits.
  • The range switch should be set to the desired range for measurement before operation.

7.2 Measuring DC Voltage

  1. Set the rotary switch to the desired "V..." range position.
  2. Connect the black test lead to the COM T- jack and the red test lead to the VΩHz jack.
  3. Connect test leads across the source or load under measurement.
  4. Read the value from the LCD. The polarity of the red lead connection will be indicated along with the DC voltage value.

Note: If the measured value is unknown, start with the highest range. If "OL" or "-OL" is displayed, it indicates an over-range situation, and a higher range must be selected. Do not input voltage more than DC 1000V or AC 750V.

7.3 Measuring AC Voltage

  1. Set the rotary switch to the desired "V~" range position.
  2. Connect the black test lead to the COM T- jack and the red test lead to the VΩHz jack.
  3. Connect test leads across the source or load under measurement.
  4. Read the value from the LCD.

7.4 Measuring DC Current

  1. Set the rotary switch to the desired "A" range position.
  2. Connect the black test lead to the COM T- jack. For currents up to 600mA, connect the red lead to the mA input jack. For 600mA to 20A currents, move the red lead to the 20A jack.
  3. Connect test leads in series with the load under measurement.
  4. Read the value from the LCD. The polarity of the red lead connection will be indicated along with the DC current value.

Note: If the measured value is unknown, start with the highest range. The maximum current for the mA socket is 600mA, and for the 20A socket is 20A. Measuring time on the 20A range should be less than 15 seconds to prevent damage.

7.5 Measuring AC Current

  1. Set the rotary switch to the desired "A~" range position.
  2. Connect the black test lead to the COM T- jack. For currents up to 600mA, connect the red lead to the mA input jack. For 600mA to 20A currents, move the red lead to the 20A jack.
  3. Connect test leads in series with the load under measurement.
  4. Read the value from the LCD.

7.6 Measuring Resistance

  1. Set the rotary switch to the desired "Ω" range position.
  2. Connect the black test lead to the COM T- jack and the red test lead to the VΩHz jack.
  3. Connect test leads across the resistance under measurement.
  4. Read the value from the LCD.

Note: Max. input overload: 250V rms < 10sec. If "OL" or "-OL" is displayed, it indicates an over-range situation. For resistance above 10MΩ, the meter may take a few seconds to get a stable reading. When the input is not connected (open circuit), "OL" or "-OL" will be displayed. When checking in-circuit resistance, ensure the circuit under test has all power removed and all capacitors have been discharged fully.

Video 1: HoldPeak HP-770M Multimeter Demonstration (DCV, Continuity, Diode, Resistance, Temperature Measurement)

7.7 Measuring Capacitance

  1. Set the rotary switch to the desired "F" range position.
  2. Connect the black test lead to the COM T- jack and the red test lead to the mA input jack.
  3. Connect test leads across the capacitance under measurement.
  4. Read the value from the LCD.

Note: Capacitors should be discharged before testing. When testing large capacitance, it may take longer for the final indication (up to 10 seconds for 100µF-60mF range). For small capacitance (<1µF), press "RELA" before measuring for accuracy.

7.8 Measuring Frequency & Duty Cycle

  1. Set the rotary switch to the desired "Hz" range position.
  2. Connect the black test lead to the COM T- jack and the red test lead to the VΩHz jack.
  3. Push the "SELECT/HOLD" key to choose between Frequency or Duty Cycle test.
  4. Connect the probe across the source or load under measurement.
  5. Read the value from the LCD.

7.9 Measuring Temperature

  1. Set the rotary switch to the desired "°C/°F" range position, then push "SELECT/HOLD" to choose between °C or °F measurement.
  2. Connect the black banana plug of the sensor to the COM T- jack and the red banana plug to the mA input jack.
  3. Place the sensor probe into the temperature field under measurement.
  4. Read the value from the LCD.

Note: Do not change the thermocouple at will, as accuracy cannot be guaranteed. Do not input voltage into the temperature function.

Demonstration of AC/DC voltage testing and temperature measurement using the probe.

Figure 4: AC/DC Test and Temperature Measurement

7.10 Diode & Audible Continuity Testing

  1. Set the rotary switch to the diode/continuity range position.
  2. Push the "SELECT/HOLD" key to choose between Diode or Audible continuity measurement.
  3. Connect the black test lead to the COM T- jack and the red test lead to the VΩHz jack.
  4. For diode range, connect the test leads across the diode. The display shows the approximate forward voltage.
  5. For audible continuity range, connect the test leads to two points of a circuit. If the resistance is lower than approx. 50Ω, the buzzer will sound.

Note: Ensure power is cut off and all capacitors are discharged before this measurement.

7.11 Transistor hFE Test

  1. Set the rotary switch to the desired "hFE" range position.
  2. Determine if the transistor is NPN or PNP and locate the Emitter, Base, and Collector leads.
  3. Insert the leads into the proper holes in the socket on the front panel.
  4. Read the approximate hFE value from the LCD.

Note: Do not connect an external voltage to the measuring terminals.

7.12 Non Contact AC Voltage (NCV) Detection

  1. Set the rotary switch to the desired "NCV" range position. The NCV green LED light will illuminate.
  2. Hold the meter so that its top is vertically and horizontally centered and contacting the conductor. When the live voltage is >90V AC rms, the NCV red and green LED lights will alternately flash with sound.

Note: Even without LED indication, voltage may still exist. Do not rely solely on non-contact voltage detectors to determine the presence of voltage. Detection may be affected by socket design, insulation thickness, and other factors. Keep the meter away from electrical noise sources (e.g., fluorescent lights, dimmable lights, motors) during tests, as these can trigger the NCV function and invalidate the test.

8. Maintenance

8.1 General Maintenance

  • You must replace the test leads if they are exposed or damaged. Use only leads with the same specifications as the original.
  • Use only a moist fabric or a small amount of detergent for cleaning. Do not use chemical solutions.
  • Do not use the meter before the back cover is properly closed and screwed securely.
  • If any abnormality occurs, stop operation immediately and send the meter for maintenance.
  • Remove the battery when not using the meter for a long time.

8.2 Battery Replacement

When the battery voltage drops below the proper operating range, the battery symbol will appear on the LCD. To replace the battery:

  1. Power off the meter and remove the test leads from the terminals.
  2. Open the cover of the battery compartment by a screwdriver.
  3. Replace the old battery with a new 9V battery (6F22 or NEDA 1604).
  4. Close the battery cover and fasten the screw.

8.3 Fuse Replacement

This meter is provided with an 800mA/250V fast fuse to protect the temperature test and current measuring circuits up to 600mA, and a 20A/250V fuse to protect the 20A range. To replace a fuse:

  1. Ensure the meter is not connected to any external circuit, power off the meter, and remove the test leads from the terminals.
  2. Open the cover of the battery compartment by a screwdriver.
  3. Replace the old fuse with the same type and rating: 5x20mm 800mA/250V fast fuse or 5x20mm 20A/250V fast fuse.
  4. Close the battery cover and fasten the screw.

9. Troubleshooting

  • Display shows "OL" or "-OL": This indicates an over-range condition. Select a higher range or ensure the input signal is within the meter's limits.
  • No display or faint display: Check the battery level. If the battery symbol is displayed or the display is faint, replace the 9V battery.
  • Inaccurate readings: Ensure the test leads are properly connected and not damaged. Verify the rotary switch is set to the correct function and range. For capacitance, ensure capacitors are discharged before testing.
  • No NCV detection: Ensure the NCV detection area is properly positioned near the AC voltage source. Keep away from electrical noise sources.
  • Meter does not power on: Check the battery. If the battery is old or depleted, replace it.

10. User Tips

  • The multimeter features a 'Hold Peak' function, which is useful for capturing maximum and minimum values during measurements. This can be accessed via the 'SELECT/HOLD' button.
  • For precise capacitance measurements, especially for small values, utilize the 'RELA' (Relative) mode after selecting the capacitance range.

11. What's in the Box

The standard packing includes the following items:

  • HoldPeak HP-770M Digital Multimeter x1
  • English User Manual x1
  • Test Leads x1 (electric rating 1000V 20A)
  • Temperature Test Probe x1 ("K" type thermocouple sensor probe)
  • Carrying Case x1
  • 9V Battery (6F22) x1 (pre-installed or included separately)
Contents of the HoldPeak HP-770M Digital Multimeter package, including the multimeter, test leads, temperature probe, 9V battery, and carrying case.

Figure 5: Package Contents

12. Additional Resources

For a more detailed and visual guide, please refer to the official user manual PDF available at: HoldPeak HP-770M User Manual (PDF).

Please note: Product specifications and content are subject to change without prior notice. Always refer to the latest official documentation for the most accurate information.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.