1. Introduction
This manual provides detailed instructions for the STEPPERONLINE CL57T Closed Loop Stepper Driver (Version 4.1). This driver offers an alternative for applications requiring high performance and reliability where servo systems might be cost-prohibitive. It integrates a 2-phase stepper motor with a digital, high-performance drive and an internal encoder to close the position, velocity, and current loops in real-time. It combines the best of servo and stepper motor technologies, delivering unique capabilities and enhancements.

2. Specifications
2.1. Key Features
- Input voltage 18-50VDC (recommended 24-48VDC)
- No loss of step, No tuning
- 500 KHz max pulse input frequency
- 16 microstep resolutions of 200-51,200 via DIP switches SW1 - SW4
- 3 output current settings of 2.8A, 5.6A and 7.0A via S1 rotating switch
- Gain tuning via S1 rotating switch
- Auto-tuning to match wide-range NEMA 17, 23 and 24 closed-loop stepper motors
- Anti-Resonance for optimal torque, extra smooth motion, low motor heating and noise
- Soft-start with no “jump” when powered on
- Optically isolated inputs with 5V or 24V
- Fault and brake outputs
- Motor rotating direction setting by SW5
- Closed loop or open loop control setting by SW6
- Step & Direction or CW&CCW pulse type setting by SW7
- Position command filter setting by SW8
- Over-voltage, over-current protections, position following error, etc.

2.2. Electrical Specifications
| Parameters | Min | Typical | Max | Unit |
|---|---|---|---|---|
| Peak Current | 2.4 (RMS 2A) | 5.6 (RMS 4A) | 7.0 (RMS 5A) | A |
| Operating Voltage | 18 | 24, 36, 48 | 50 | VDC |
| Logic input signal current | 7 | 10 | 16 | mA |
| Pulse input frequency | 0 | - | 500 | kHz |
| Brake output signal current | - | - | 100 | mA |
| Alarm output voltage | - | - | 24 | VDC |
| Minimal pulse width | 1.0 | - | - | µs |
| Minimal direction setup | 2.0 | - | - | µs |
| Isolation resistance | 500 | - | - | MΩ |
2.3. Environment Specifications
| Cooling | Natural Cooling or Forced Cooling | |
|---|---|---|
| Operating Environment | Environment | Avoid dust, oil fog and corrosive gases |
| Humidity | 40%RH - 90%RH | |
| Operating Temperature | 0°C ~ 40°C (32°F - 102°F) | |
| Vibration | 10-50Hz / 0.15mm | |
| Storage Temperature | -20°C ~ 65°C (-4°F - 149°F) | |
| Weight | Approx. 280 g (9.9 Oz) | |

2.4. Mechanical Specifications

3. Setup
3.1. Connections and LED Indication
The CL57T(V4.1) closed loop stepper drive has 5 connection blocks: P1 (Control and Digital Output), P2 (Encoder Signals Input), P3 (Motor), P4 (Power), and P5 (Tuning Port).

3.1.1. P1 - Control and Digital Output Connections
The P1 connector handles control signals and 2 digital outputs. Key pins include PUL+ (CW+), PUL- (CW-), DIR+ (CCW+), DIR- (CCW-), ENA+ (Enable), ENA- (Enable), ALM (Alarm), BRK (Brake), and COMO (Common Output).
3.1.2. P2 - Encoder Signals Input Connector
The P2 connector is for encoder signals. Pins include EB+, EB-, EA+, EA-, VCC (+5V output), and EGND (Power ground).
3.1.3. P3 - Motor Connector
Connect motor wires to A+, A-, B+, and B- terminals.
3.1.4. P4 - Power Connector
Connect power supply to GND and +VDC terminals. Recommended supply voltage is 24-48VDC.
Warning: Do not plug/unplug P3 or P4 connectors while the drive is powered on to avoid damage or injury.
3.1.5. P5 - Debug Port
The P5 connector is an RS232 communication port for PC connection, used to modify drive parameters. It is not intended for equipment control due to insufficient precision and stability.

3.2. Power Supply Selection
The CL57T(V4.1) operates within 18-50VDC. Selecting the correct supply voltage and output current is crucial for optimal performance. Higher voltage allows for higher motor speed, but may increase noise and heating. For lower motion speed requirements, a lower supply voltage is recommended to reduce noise and improve reliability.
3.2.1. Power Supply Sharing
Multiple CL57T(V4.1) drives can share a single power supply if it has sufficient capacity. To prevent cross-interference, connect each stepper drive directly to the shared power supply, avoiding daisy-chain connections.
3.3. Switch Configurations
3.3.1. S1 - Rotating Switch (Current & Gain)
The S1 rotating switch is used to set the peak current of the drive and adjust motion gain. It offers 3 output current settings: 2.8A, 5.6A, and 7.0A. Gain tuning is also performed via S1.
| Peak Current | RMS Current | Code | Velocity loop Ki | Position loop Kp | Velocity loop Kp | Remark |
|---|---|---|---|---|---|---|
| 2.8A | 2A | 0 (factory) | 0 | 25 | 25 | 1) Velocity loop Ki indicates the stop time and position accuracy. "0" indicates the stop time is long, but the position error is smaller."16" means the stop time is short, but the position error is slightly larger. 2) Position loop Kp and velocity loop Kp is a pair of composite parameters that represent rigidity. "25" and "25"composite parameters indicate the rigidity is weak, "100" and "5"composite parameters indicate the rigidity is strong. Sometimes if the motor will rotate after stopping, it can increase the value of position loop Kp, but if the value is too large, the motor will have noise. 3) Usually keep factory settings |
| 1 | 0 | 50 | 15 | |||
| 2 | 16 | 25 | 25 | |||
| 3 | 16 | 50 | 15 | |||
| 4 | 0 | 25 | 25 | |||
| 5 | 0 | 50 | 15 | |||
| 5.6A | 4A | 6 | 0 | 100 | 5 | |
| 7 | 16 | 25 | 25 | |||
| 8 | 16 | 50 | 15 | |||
| 9 | 16 | 100 | 5 | |||
| 7A | 5A | A | 0 | 25 | 25 | |
| B | 0 | 50 | 15 | |||
| C | 0 | 100 | 5 | |||
| D | 16 | 25 | 25 | |||
| E | 16 | 50 | 15 | |||
| F | 16 | 100 | 5 |
3.3.2. S2 - DIP Switch Configurations (Microstep & Mode Setting)
The 8-bit DIP switch S2 is used to configure microstep resolution (SW1-SW4) and mode settings (SW5-SW8).

Micro Step (SW1-SW4)
The CL57T(V4.1) has 16 microstep settings. Refer to the table below for specific configurations:
| Micro step | Pulses/Rev. (for 1.8°motor) | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|---|
| 1 | 200 | on | on | on | on |
| 4 | 800 | off | on | on | on |
| 8 | 1600 | on | off | on | on |
| 16 | 3200 | off | off | on | on |
| 32 | 6400 | on | on | off | on |
| 64 | 12800 | off | on | off | on |
| 128 | 25600 | on | off | off | on |
| 256 | 51200 | off | off | off | on |
| 5 | 1000 | on | on | on | off |
| 10 | 2000 | off | on | on | off |
| 20 | 4000 | on | off | on | off |
| 25 | 5000 | off | off | on | off |
| 40 | 8000 | on | on | off | off |
| 50 | 10000 | off | on | off | off |
| 100 | 20000 | on | off | off | off |
| 200 | 40000 | off | off | off | off |

Mode Setting (SW5-SW8)
These switches control Rotation Direction, Control Mode, Pulse Mode, and Pulse Filter Time.
| Setting | Function | ON | OFF |
|---|---|---|---|
| SW5 | Rotation Direction | CW (clockwise) | CCW (counterclockwise) |
| SW6 | Control Mode | Open loop control | Closed loop control |
| SW7 | Pulse Mode | CW/CCW (double pulse) | PUL/DIR (single pulse) |
| SW8 | Pulse Filter Time | Yes (10ms) | No (1.5ms) |

3.3.3. S3 - Selector Switch (Control Signal Voltage)
The 1-bit selector switch S3 is located on the top of the drive and is used to configure the voltage of control signals (5V or 24V). The factory setting is 24V. If using a 5V control signal, S3 MUST be set to 5V.
3.4. Typical Connection
A complete closed-loop stepper system includes a stepper motor with encoder, the CL57T(V4.1) drive, a power supply, and a controller (pulse generator). The typical connection diagram illustrates how these components are wired together.

Notes on Typical Connection:
- Pulse and direction inputs level 5V or 24V are selected by selector switch S3. If S3 is set to 5V while using 24V, it will damage the input photo-coupling.
- Enable (ENA) signal is 5V~24V compatible.
3.4.1. Digital Input Connection
The CL57T(V4.1) supports differential or single-ended control signals (pulse, direction, enable) in open-collector or PNP connection via the P1 connector. It is recommended to add an EMI line filter between the power supply and the drive to enhance noise immunity.
3.4.2. Fault Output Connection
The fault output is optional and can be connected in either sinking or sourcing configurations. When over-voltage or over-current protection is active, the red status LED blinks, and the impedance state between ALM and COM- changes, which can be detected.
3.4.3. Brake Output Connection
The drive features a special brake output that requires a relay to drive the motor brake.
4. Operating
4.1. LED Status Lights
The drive has two LED indicators:
- Green LED: Power indicator. It should always be ON during normal operation.
- Red LED: Alarm status indicator. It is OFF during normal operation but will turn ON and flash periodically (e.g., 3-second intervals) when alarm protections are enabled.
4.2. Sequence Chart of Control Signals
To ensure proper operation and prevent faults, PUL, DIR, and ENA signals must adhere to specific timing rules.

Remarks:
- t1: ENA must be ahead of DIR by at least 200ms.
- t2: DIR must be ahead of PUL effective edge by 2µs.
- t3: Pulse width not less than 1µs.
- t4: Low level width not less than 1µs.
- Duty cycle of PUL signal is recommended 50%.
5. Maintenance
5.1. Heat Dissipation
The CL57T(V4.1) reliable working temperature should not exceed 40°C (109°F). It is recommended to mount the drive vertically to maximize heat dissipation. If necessary, a cooling fan should be used. When installing multiple CL57T(V4.1) drives, maintain a minimum spacing of 30mm (1.2 inches) between them.
6. Troubleshooting
The drive incorporates built-in protection features. When these protections are active, the motor shaft will be free, and the red LED blinks. Repower the drive after resolving the issue to restore normal function.
If the drive does not operate properly, first determine if the problem is electrical or mechanical. Systematically isolate components to identify the cause. Document each step for future reference or technical support.
| Blink time(s) | Sequence wave of red LED | Description | Troubleshooting |
|---|---|---|---|
| 1 | Over-current | Turn off power immediately. Check wiring for short-circuits. | |
| 2 | Over-voltage | Turn off power immediately. Check if power voltage is higher than 90VDC. | |
| 3 | Chip error | Restart power supply. If alarm persists, contact after-sale. | |
| 4 | Fail to lock motor shaft | Drive not connected to motor, or motor power cable issue. | |
| 5 | EEPROM error | Restart power supply. If alarm persists, contact after-sale. | |
| 6 | Fail to auto tuning | Restart power supply. If alarm persists, contact after-sale. | |
| 7 | Position following error | Set SW6 to "ON" (open loop mode). If alarm disappears, check encoder wiring. Motor torque may be insufficient or speed too high. | |
| Always | - | PCB board is burned out | Restart power supply. If alarm persists, contact after-sale. |

| Symptoms | Possible Problems | Solutions |
|---|---|---|
| Motor is not rotating | No power | Connect power supply correctly |
| Microstep resolution setting is wrong | Set appropriate microstep | |
| Fault condition exists | Check wiring and restart power | |
| The drive is disabled | Drive restore factory setting, and keep ENA+, ENA- input signals unconnected. | |
| Wrong motor rotation direction | The Direction signal level is reverse | Toggle the SW5 DIP switch |
| Erratic motor motion | Control signal is too weak | Ensure the current of control signal is within 7-16mA |
| Control signal is interfered | Do not tie the control signal cable with power cable together | |
| Wrong motor connection | Refer to user manual of drive and motor datasheet | |
| Something wrong with motor coil | Check the motor is normal | |
| Motor stalls during acceleration | Current setting is too small | Choose another power supply with larger power or increase the output current of drive |
| Motor is undersized for the application | Choose another motor with higher torque | |
| Acceleration is set too high | Reduce the acceleration | |
| Power supply voltage too low | Choose another power supply with large voltage output | |
| Excessive motor & drive heating | Inadequate heat sinking / cooling | Refer to chapter 2.4 (Heat Dissipation) |
| Motor peak current setting is too high | Reduce the current value refer to motor datasheet | |
| Motor vibration when power on | Speed loop Kp is too high | Reduce the speed loop Kp value |

7. User Tips
- The motor management is of half stepper type.
- For a 1.8° motor, 200 pulses per revolution (full step) means 400 passes for one round in half-step mode, resulting in 0.9° per half-step. This is essential for precise programming.
8. Warranty and Support
For any issues that cannot be resolved using the troubleshooting guide, please contact our after-sale service or Technical Support staff. Providing detailed documentation of your troubleshooting steps will greatly assist in diagnosing and resolving the problem.
A PDF version of this user manual is available for download: CL57T(V4.1) Closed Loop Stepper Driver User Manual (PDF)