1. Introduction

This manual provides detailed instructions for the STEPPERONLINE CL57T Closed Loop Stepper Driver (Version 4.1). This driver offers an alternative for applications requiring high performance and reliability where servo systems might be cost-prohibitive. It integrates a 2-phase stepper motor with a digital, high-performance drive and an internal encoder to close the position, velocity, and current loops in real-time. It combines the best of servo and stepper motor technologies, delivering unique capabilities and enhancements.

Front view of the CL57T Closed-Loop Stepper Driver with terminal labels and DIP switch tables.
Figure 1: CL57T Closed-Loop Stepper Driver Overview
Video 1: Product overview showcasing the CL57T driver's features and specifications.

2. Specifications

2.1. Key Features

  • Input voltage 18-50VDC (recommended 24-48VDC)
  • No loss of step, No tuning
  • 500 KHz max pulse input frequency
  • 16 microstep resolutions of 200-51,200 via DIP switches SW1 - SW4
  • 3 output current settings of 2.8A, 5.6A and 7.0A via S1 rotating switch
  • Gain tuning via S1 rotating switch
  • Auto-tuning to match wide-range NEMA 17, 23 and 24 closed-loop stepper motors
  • Anti-Resonance for optimal torque, extra smooth motion, low motor heating and noise
  • Soft-start with no “jump” when powered on
  • Optically isolated inputs with 5V or 24V
  • Fault and brake outputs
  • Motor rotating direction setting by SW5
  • Closed loop or open loop control setting by SW6
  • Step & Direction or CW&CCW pulse type setting by SW7
  • Position command filter setting by SW8
  • Over-voltage, over-current protections, position following error, etc.
Image highlighting key features and electrical specifications of the CL57T driver.
Figure 2: Key Features and Electrical Specifications

2.2. Electrical Specifications

ParametersMinTypicalMaxUnit
Peak Current2.4 (RMS 2A)5.6 (RMS 4A)7.0 (RMS 5A)A
Operating Voltage1824, 36, 4850VDC
Logic input signal current71016mA
Pulse input frequency0-500kHz
Brake output signal current--100mA
Alarm output voltage--24VDC
Minimal pulse width1.0--µs
Minimal direction setup2.0--µs
Isolation resistance500--MΩ

2.3. Environment Specifications

CoolingNatural Cooling or Forced Cooling
Operating EnvironmentEnvironmentAvoid dust, oil fog and corrosive gases
Humidity40%RH - 90%RH
Operating Temperature0°C ~ 40°C (32°F - 102°F)
Vibration10-50Hz / 0.15mm
Storage Temperature-20°C ~ 65°C (-4°F - 149°F)
WeightApprox. 280 g (9.9 Oz)
Tables for Electrical Specifications and Operating Environment of the CL57T driver.
Figure 3: Electrical and Environmental Specifications

2.4. Mechanical Specifications

Mechanical Specifications diagram with dimensions for the CL57T driver.
Figure 4: Mechanical Specifications (unit: mm)

3. Setup

3.1. Connections and LED Indication

The CL57T(V4.1) closed loop stepper drive has 5 connection blocks: P1 (Control and Digital Output), P2 (Encoder Signals Input), P3 (Motor), P4 (Power), and P5 (Tuning Port).

Top view of the CL57T stepper driver showing the DIP switches and connectors.
Figure 5: CL57T Connectors and Switches

3.1.1. P1 - Control and Digital Output Connections

The P1 connector handles control signals and 2 digital outputs. Key pins include PUL+ (CW+), PUL- (CW-), DIR+ (CCW+), DIR- (CCW-), ENA+ (Enable), ENA- (Enable), ALM (Alarm), BRK (Brake), and COMO (Common Output).

3.1.2. P2 - Encoder Signals Input Connector

The P2 connector is for encoder signals. Pins include EB+, EB-, EA+, EA-, VCC (+5V output), and EGND (Power ground).

3.1.3. P3 - Motor Connector

Connect motor wires to A+, A-, B+, and B- terminals.

3.1.4. P4 - Power Connector

Connect power supply to GND and +VDC terminals. Recommended supply voltage is 24-48VDC.

Warning: Do not plug/unplug P3 or P4 connectors while the drive is powered on to avoid damage or injury.

3.1.5. P5 - Debug Port

The P5 connector is an RS232 communication port for PC connection, used to modify drive parameters. It is not intended for equipment control due to insufficient precision and stability.

RS232 debugging cable for the CL57T driver.
Figure 6: RS232 Debugging Cable

3.2. Power Supply Selection

The CL57T(V4.1) operates within 18-50VDC. Selecting the correct supply voltage and output current is crucial for optimal performance. Higher voltage allows for higher motor speed, but may increase noise and heating. For lower motion speed requirements, a lower supply voltage is recommended to reduce noise and improve reliability.

3.2.1. Power Supply Sharing

Multiple CL57T(V4.1) drives can share a single power supply if it has sufficient capacity. To prevent cross-interference, connect each stepper drive directly to the shared power supply, avoiding daisy-chain connections.

3.3. Switch Configurations

3.3.1. S1 - Rotating Switch (Current & Gain)

The S1 rotating switch is used to set the peak current of the drive and adjust motion gain. It offers 3 output current settings: 2.8A, 5.6A, and 7.0A. Gain tuning is also performed via S1.

Peak CurrentRMS CurrentCodeVelocity loop KiPosition loop KpVelocity loop KpRemark
2.8A2A0 (factory)025251) Velocity loop Ki indicates the stop time and position accuracy. "0" indicates the stop time is long, but the position error is smaller."16" means the stop time is short, but the position error is slightly larger.
2) Position loop Kp and velocity loop Kp is a pair of composite parameters that represent rigidity. "25" and "25"composite parameters indicate the rigidity is weak, "100" and "5"composite parameters indicate the rigidity is strong. Sometimes if the motor will rotate after stopping, it can increase the value of position loop Kp, but if the value is too large, the motor will have noise.
3) Usually keep factory settings
105015
2162525
3165015
402525
505015
5.6A4A601005
7162525
8165015
9161005
7A5AA02525
B05015
C01005
D162525
E165015
F161005

3.3.2. S2 - DIP Switch Configurations (Microstep & Mode Setting)

The 8-bit DIP switch S2 is used to configure microstep resolution (SW1-SW4) and mode settings (SW5-SW8).

Diagram showing the 8-bit DIP switch S2 configuration for microstep, control mode, rotation direction, pulse mode, and pulse filter time.
Figure 7: DIP Switch S2 Configuration
Micro Step (SW1-SW4)

The CL57T(V4.1) has 16 microstep settings. Refer to the table below for specific configurations:

Micro stepPulses/Rev. (for 1.8°motor)SW1SW2SW3SW4
1200onononon
4800offononon
81600onoffonon
163200offoffonon
326400ononoffon
6412800offonoffon
12825600onoffoffon
25651200offoffoffon
51000onononoff
102000offononoff
204000onoffonoff
255000offoffonoff
408000ononoffoff
5010000offonoffoff
10020000onoffoffoff
20040000offoffoffoff
Table for Micro Step (SW1-SW4) showing pulses/rev and DIP switch settings.
Figure 8: Microstep Settings (SW1-SW4)
Mode Setting (SW5-SW8)

These switches control Rotation Direction, Control Mode, Pulse Mode, and Pulse Filter Time.

SettingFunctionONOFF
SW5Rotation DirectionCW (clockwise)CCW (counterclockwise)
SW6Control ModeOpen loop controlClosed loop control
SW7Pulse ModeCW/CCW (double pulse)PUL/DIR (single pulse)
SW8Pulse Filter TimeYes (10ms)No (1.5ms)
Table for Mode Setting (SW5-SW8) showing functions and ON/OFF states.
Figure 9: Mode Setting (SW5-SW8)

3.3.3. S3 - Selector Switch (Control Signal Voltage)

The 1-bit selector switch S3 is located on the top of the drive and is used to configure the voltage of control signals (5V or 24V). The factory setting is 24V. If using a 5V control signal, S3 MUST be set to 5V.

3.4. Typical Connection

A complete closed-loop stepper system includes a stepper motor with encoder, the CL57T(V4.1) drive, a power supply, and a controller (pulse generator). The typical connection diagram illustrates how these components are wired together.

Comparison table of CL57T versions (V4.1, V4.0, V3.0) with their respective features.
Figure 10: Typical Connection Diagram (Refer to PDF for full diagram)

Notes on Typical Connection:

  • Pulse and direction inputs level 5V or 24V are selected by selector switch S3. If S3 is set to 5V while using 24V, it will damage the input photo-coupling.
  • Enable (ENA) signal is 5V~24V compatible.

3.4.1. Digital Input Connection

The CL57T(V4.1) supports differential or single-ended control signals (pulse, direction, enable) in open-collector or PNP connection via the P1 connector. It is recommended to add an EMI line filter between the power supply and the drive to enhance noise immunity.

3.4.2. Fault Output Connection

The fault output is optional and can be connected in either sinking or sourcing configurations. When over-voltage or over-current protection is active, the red status LED blinks, and the impedance state between ALM and COM- changes, which can be detected.

3.4.3. Brake Output Connection

The drive features a special brake output that requires a relay to drive the motor brake.

4. Operating

4.1. LED Status Lights

The drive has two LED indicators:

  • Green LED: Power indicator. It should always be ON during normal operation.
  • Red LED: Alarm status indicator. It is OFF during normal operation but will turn ON and flash periodically (e.g., 3-second intervals) when alarm protections are enabled.

4.2. Sequence Chart of Control Signals

To ensure proper operation and prevent faults, PUL, DIR, and ENA signals must adhere to specific timing rules.

Table of Protection Indications with red LED blink times, descriptions, and troubleshooting steps.
Figure 11: Sequence Chart of Control Signals (Refer to PDF for full diagram)

Remarks:

  • t1: ENA must be ahead of DIR by at least 200ms.
  • t2: DIR must be ahead of PUL effective edge by 2µs.
  • t3: Pulse width not less than 1µs.
  • t4: Low level width not less than 1µs.
  • Duty cycle of PUL signal is recommended 50%.

5. Maintenance

5.1. Heat Dissipation

The CL57T(V4.1) reliable working temperature should not exceed 40°C (109°F). It is recommended to mount the drive vertically to maximize heat dissipation. If necessary, a cooling fan should be used. When installing multiple CL57T(V4.1) drives, maintain a minimum spacing of 30mm (1.2 inches) between them.

6. Troubleshooting

The drive incorporates built-in protection features. When these protections are active, the motor shaft will be free, and the red LED blinks. Repower the drive after resolving the issue to restore normal function.

If the drive does not operate properly, first determine if the problem is electrical or mechanical. Systematically isolate components to identify the cause. Document each step for future reference or technical support.

Blink time(s)Sequence wave of red LEDDescriptionTroubleshooting
1Over-currentTurn off power immediately. Check wiring for short-circuits.
2Over-voltageTurn off power immediately. Check if power voltage is higher than 90VDC.
3Chip errorRestart power supply. If alarm persists, contact after-sale.
4Fail to lock motor shaftDrive not connected to motor, or motor power cable issue.
5EEPROM errorRestart power supply. If alarm persists, contact after-sale.
6Fail to auto tuningRestart power supply. If alarm persists, contact after-sale.
7Position following errorSet SW6 to "ON" (open loop mode). If alarm disappears, check encoder wiring. Motor torque may be insufficient or speed too high.
Always-PCB board is burned outRestart power supply. If alarm persists, contact after-sale.
Table of Protection Indications with red LED blink times, descriptions, and troubleshooting steps.
Figure 12: Protection Indications and Troubleshooting
SymptomsPossible ProblemsSolutions
Motor is not rotatingNo powerConnect power supply correctly
Microstep resolution setting is wrongSet appropriate microstep
Fault condition existsCheck wiring and restart power
The drive is disabledDrive restore factory setting, and keep ENA+, ENA- input signals unconnected.
Wrong motor rotation directionThe Direction signal level is reverseToggle the SW5 DIP switch
Erratic motor motionControl signal is too weakEnsure the current of control signal is within 7-16mA
Control signal is interferedDo not tie the control signal cable with power cable together
Wrong motor connectionRefer to user manual of drive and motor datasheet
Something wrong with motor coilCheck the motor is normal
Motor stalls during accelerationCurrent setting is too smallChoose another power supply with larger power or increase the output current of drive
Motor is undersized for the applicationChoose another motor with higher torque
Acceleration is set too highReduce the acceleration
Power supply voltage too lowChoose another power supply with large voltage output
Excessive motor & drive heatingInadequate heat sinking / coolingRefer to chapter 2.4 (Heat Dissipation)
Motor peak current setting is too highReduce the current value refer to motor datasheet
Motor vibration when power onSpeed loop Kp is too highReduce the speed loop Kp value
Table of Problem Symptoms, Possible Causes, and Solutions for troubleshooting.
Figure 13: Common Problem Symptoms and Solutions

7. User Tips

  • The motor management is of half stepper type.
  • For a 1.8° motor, 200 pulses per revolution (full step) means 400 passes for one round in half-step mode, resulting in 0.9° per half-step. This is essential for precise programming.

8. Warranty and Support

For any issues that cannot be resolved using the troubleshooting guide, please contact our after-sale service or Technical Support staff. Providing detailed documentation of your troubleshooting steps will greatly assist in diagnosing and resolving the problem.

A PDF version of this user manual is available for download: CL57T(V4.1) Closed Loop Stepper Driver User Manual (PDF)

© 2023 STEPPERONLINE. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.