1. Introduction
The MASTECH MY68 is a new generation digital multimeter designed for accurate and reliable measurement of various electrical parameters. Featuring a 3 3/4 LCD display with 3999 counts and auto-ranging capabilities, it is suitable for a wide range of applications in electrical fields, home use, hobbies, electrical maintenance, factory environments, and educational settings.

2. Key Features
- Auto and Manual Ranging: Automatically selects the appropriate measurement range or allows manual selection.
- Data Hold: Freezes the displayed measurement for easy reading.
- Diode Test: Checks the functionality of diodes.
- Transistor Test: Measures transistor hFE (current gain).
- Continuity Test: Audible indication for circuit continuity.
- Comprehensive Measurement: Tests AC/DC voltage, AC/DC current, resistance, capacitance, and frequency.
- Over Range Indication: LCD displays "OL" when the measurement exceeds the selected range.
- Low Battery Indication: Alerts the user when the battery needs replacement.

3. Technical Specifications
| Parameter | Range | Accuracy |
|---|---|---|
| DC Voltage | 400mV/4V/40V/400V 1000V | ±(0.7%+2) ±(0.8%+2) |
| AC Voltage | 400mV 4V/40V/400V 750V | ±(3%+3) ±(0.8%+3) ±(1.0%+3) |
| DC Current | 400uA/4000uA/40mA/400mA 10A | ±(1.0%+5) ±(1.5%+8) |
| AC Current | 400µA/4000uA/40mA/400mA 10A | ±(1.5%+8) ±(2.0%+10) |
| Resistance | 400Ω/4kΩ/40kΩ/400kΩ/4MΩ 40MΩ | ±(1.2%+2) ±(2%+5) |
| Capacitance | 4nF/40nF/400nF/4µF/40µF/200µF | ±(4.0%+15) |
| Frequency | 10/100/1000/10kHz/200kHz | ±2.0% |
General Characteristics:
- Power Supply: 1 x 6F22 (9V) battery (not included)
- Dimensions: 91(L) x 189(W) x 31.5(H) mm
- Weight: Approximately 310g (including battery)
- Color: Black & Green
- Operating Temperature: 0 - 40 ℃
- DIY Supplies: Electrical
- Certification: CE
- Origin: Mainland China
4. Package Contents
Upon opening the package, please verify that all items listed below are present and in good condition:
- 1 x MASTECH MY68 Digital Multimeter
- 1 x Set of Test Leads (Red and Black)
- 1 x User Manual
Note: Battery (1 x 6F22 9V) is not included in the package.

5. Safety Information
To ensure safe operation and avoid damage to the meter, please read and follow all safety instructions carefully before use. Keep this manual for future reference.
- Always ensure the meter is in the correct function and range before making measurements.
- Do not apply voltage or current that exceeds the maximum specified limits for the meter.
- Use extreme caution when working with voltages above 60V DC or 30V AC RMS, as these pose a shock hazard.
- Before measuring current, ensure the circuit is de-energized and the meter is connected in series with the load.
- Never connect the test leads across a voltage source when the rotary switch is set to current, resistance, or continuity mode.
- Replace the battery immediately when the low battery indicator appears to ensure accurate readings.
- Do not operate the meter if it appears damaged or if the test leads are damaged.
- Always disconnect the test leads from the circuit before changing the function or range.
6. Setup and Initial Use
6.1 Battery Installation
- Ensure the multimeter is turned OFF.
- Locate the battery compartment cover on the back of the unit.
- Use a screwdriver to remove the screw securing the battery cover.
- Carefully remove the cover.
- Insert one 9V (6F22) battery, observing the correct polarity (+ and -).
- Replace the battery cover and secure it with the screw.
6.2 Connecting Test Leads
- For most voltage, resistance, and continuity measurements, insert the red test lead into the "VΩCx" jack and the black test lead into the "COM" jack.
- For current measurements (mA), insert the red test lead into the "mA" jack and the black test lead into the "COM" jack.
- For high current measurements (10A), insert the red test lead into the "10A MAX" jack and the black test lead into the "COM" jack.

7. Operating Modes
The MASTECH MY68 features a rotary switch to select different measurement functions. The display will show the selected function and measurement value.
7.1 DC Voltage Measurement (V-)
Turn the rotary switch to the V- position. Connect the test leads in parallel to the DC voltage source. The meter will automatically select the range.
7.2 AC Voltage Measurement (V~)
Turn the rotary switch to the V~ position. Connect the test leads in parallel to the AC voltage source. The meter will automatically select the range.
7.3 DC Current Measurement (A-)
Turn the rotary switch to the A- position. Connect the meter in series with the circuit. Ensure the correct input jack (mA or 10A) is used based on the expected current.
7.4 AC Current Measurement (A~)
Turn the rotary switch to the A~ position. Connect the meter in series with the circuit. Ensure the correct input jack (mA or 10A) is used based on the expected current.
7.5 Resistance Measurement (Ω)
Turn the rotary switch to the Ω position. Connect the test leads across the component to be measured. Ensure the circuit is de-energized before measuring resistance.
7.6 Capacitance Measurement (Cap)
Turn the rotary switch to the Cap position. Connect the test leads across the capacitor. Ensure the capacitor is discharged before measurement.
7.7 Frequency Measurement (Hz)
Turn the rotary switch to the Hz position. Connect the test leads to the signal source. The meter will display the frequency.
7.8 Diode Test (Diode Symbol)
Turn the rotary switch to the diode symbol position. Connect the red lead to the anode and the black lead to the cathode of the diode. The forward voltage drop will be displayed.
7.9 Continuity Test (Audible Symbol)
Turn the rotary switch to the continuity symbol position. If the resistance between the test leads is below a certain threshold, an audible beep will sound.
7.10 Transistor hFE Test (hFE)
Turn the rotary switch to the hFE position. Insert the transistor leads into the appropriate NPN or PNP sockets on the meter. The hFE value will be displayed.
7.11 Data Hold Function (DATA-H)
Press the "DATA-H" button to freeze the current reading on the display. Press it again to release the hold function.
8. Maintenance
8.1 Cleaning
Wipe the meter with a damp cloth and mild detergent. Do not use abrasives or solvents. Keep the meter dry.
8.2 Battery Replacement
When the low battery indicator appears on the display, replace the 9V battery as described in the Setup section (6.1 Battery Installation). Failure to do so may result in inaccurate readings.
8.3 Fuse Replacement
If the current measurement function fails, the fuse may need replacement. Refer to the internal diagram (if available in the full manual) for fuse specifications and location. Always replace with a fuse of the same type and rating.
9. Troubleshooting
- Display shows "OL": This indicates an over-range condition. The measured value is higher than the selected range. Switch to a higher range or ensure the meter is connected correctly.
- No display or faint display: Check the battery. Replace if necessary.
- Incorrect readings: Ensure the test leads are properly connected to the correct input jacks and the rotary switch is set to the appropriate function and range. Check battery level.
- No continuity beep: Ensure the circuit is de-energized. Check if the test leads are making good contact.
- Current measurement not working: Check the fuse. If blown, replace it with the correct type and rating.
10. User Tips
- For quick checks, the auto-ranging feature is very convenient, but for precise measurements within a known range, manually selecting the range can sometimes provide faster results.
- Always double-check your connections before applying power to the circuit or taking a measurement, especially when switching between voltage and current modes.
- Utilize the kickstand on the back of the multimeter for hands-free operation and better viewing angles.

11. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact information provided by your retailer or the manufacturer's official website. Keep your purchase receipt as proof of purchase.