MESTEK DM90A

Contents

MESTEK DM90A Series Digital Multimeter User Manual

Models: DM90A, DM90E, DM90S

1. Introduction

The MESTEK DM90A series digital multimeters (DM90A, DM90E, DM90S) are compact, auto-ranging (DM90A, DM90S) or manual-ranging (DM90E) instruments designed for electrical measurements. They feature a 6000-count display, True RMS capability (DM90A), and various functions including voltage, current, resistance, capacitance, frequency, temperature (DM90A only), diode, continuity, and Non-Contact Voltage (NCV) detection. This manual provides essential information for safe and effective use of your multimeter.

2. Safety Information

Always observe safety precautions when using the multimeter. Incorrect use can lead to electric shock, injury, or damage to the instrument. Read all instructions carefully before use.

  • Do not exceed the maximum input values for any function.
  • Ensure the test leads are properly connected and the function switch is in the correct position before making measurements.
  • Do not use the multimeter if it appears damaged or if the test leads are damaged.
  • Replace batteries promptly when the low battery indicator appears.
  • Do not attempt to measure voltage or current on circuits exceeding the specified limits (e.g., 600V DC or 600V AC RMS).
  • Use caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC, as they pose a shock hazard.

3. Product Overview

The MESTEK DM90A series multimeters are designed for ease of use and portability. Key features include:

  • Display: LCD with 6000 counts maximum display.
  • Backlight & Flashlight: For use in low-light conditions.
  • Data Hold (HOLD): Freezes the current reading on the display.
  • Non-Contact Voltage (NCV): Detects AC voltage without direct contact.
  • Overload Protection: Full measuring range overload protection.
  • Automatic Power-off: After 15 minutes of inactivity to conserve battery life.
  • Kickstand: Integrated for convenient hands-free operation (DM90E shown with kickstand).
MESTEK DM90A Multimeter Features
Figure 3.1: MESTEK DM90A Multimeter and its key features (DM90A model shown).
MESTEK DM90E Multimeter Features
Figure 3.2: MESTEK DM90E Multimeter and its key features (DM90E model shown).

4. Setup

4.1. Unboxing

Carefully open the product packaging and remove all contents. Verify that all items are present:

  • MESTEK DM90A/DM90E/DM90S Multimeter
  • Test Leads (10A cable pen tip probe)
  • Temperature Probe (Only for DM90A model)
  • User Manual
  • Certificate/Warranty Card
MESTEK DM90A Package Contents
Figure 4.1: Typical package contents for the DM90A model.
Video 4.1: Unboxing and initial inspection of the MESTEK DM90A multimeter.

4.2. Battery Installation

The multimeter requires 3 x 1.5V AAA batteries (not included). To install or replace batteries:

  1. Ensure the multimeter is turned OFF and test leads are disconnected.
  2. Locate the battery compartment cover on the back of the unit.
  3. Use a screwdriver to open the battery compartment.
  4. Insert three AAA batteries, observing correct polarity (+/-).
  5. Close the battery compartment cover and secure it with the screw.

4.3. Connecting Test Leads

Always connect the test leads correctly for the desired measurement function.

  • For most measurements (Voltage, Resistance, Capacitance, Diode, Continuity, Frequency, Temperature), connect the RED test lead to the 'VΩmA' jack and the BLACK test lead to the 'COM' jack.
  • For measuring currents up to 600mA, connect the RED test lead to the 'VΩmA' jack and the BLACK test lead to the 'COM' jack.
  • For measuring currents up to 10A, connect the RED test lead to the '10A FUSED' jack and the BLACK test lead to the 'COM' jack.

5. Operating Instructions

5.1. Power On/Off

Turn the rotary switch from 'OFF' to any desired function to power on the multimeter. To power off, turn the rotary switch back to 'OFF'. The multimeter will automatically power off after 15 minutes of inactivity.

5.2. Function Selection

Rotate the central dial to select the desired measurement function (e.g., V~ for AC Voltage, V- for DC Voltage, Ω for Resistance, etc.).

5.3. Measurement Functions

5.3.1. Voltage Measurement (AC/DC)

  1. Turn the rotary switch to V~ (AC Voltage) or V- (DC Voltage).
  2. Connect the test leads to the circuit in parallel with the component to be measured.
  3. Read the voltage value on the display.

5.3.2. Current Measurement (AC/DC)

  1. Turn the rotary switch to A~ (AC Current) or A- (DC Current).
  2. Select the appropriate current range (e.g., 600uA, 6000uA, 60mA, 600mA, 10A) using the 'FUNC/Hz' button if necessary.
  3. Connect the multimeter in series with the circuit.
  4. Read the current value on the display.

5.3.3. Resistance Measurement (Ω)

  1. Turn the rotary switch to Ω.
  2. Connect the test leads across the component to be measured.
  3. Read the resistance value on the display.

5.3.4. Capacitance Measurement

  1. Turn the rotary switch to the capacitance symbol (e.g., 9.999mF~999.9uF range).
  2. Connect the test leads across the capacitor.
  3. Read the capacitance value on the display.

5.3.5. Frequency Measurement (Hz)

  1. Turn the rotary switch to Hz.
  2. Connect the test leads to the signal source.
  3. Read the frequency value on the display.

5.3.6. Temperature Measurement (DM90A only)

  1. Turn the rotary switch to °C/°F.
  2. Connect the temperature probe to the multimeter's input jacks (red to VΩmA, blue/black to COM).
  3. Place the tip of the temperature probe on or near the object whose temperature is to be measured.
  4. Read the temperature value on the display.
MESTEK DM90A Temperature Measurement
Figure 5.1: DM90A model demonstrating temperature measurement with the included probe.

5.3.7. Diode Test

  1. Turn the rotary switch to the diode symbol.
  2. Connect the red test lead to the anode and the black test lead to the cathode of the diode.
  3. Read the forward voltage drop on the display. Reverse the leads to check for open circuit.

5.3.8. Continuity Test

  1. Turn the rotary switch to the continuity symbol (buzzer icon).
  2. Connect the test leads across the circuit or component.
  3. If the resistance is below a certain threshold, the buzzer will sound, indicating continuity.

5.3.9. Non-Contact Voltage (NCV) Detection

  1. Turn the rotary switch to NCV.
  2. Move the top of the multimeter near an AC voltage source.
  3. The multimeter will beep and the NCV indicator will light up if AC voltage is detected.

5.4. Special Functions

  • HOLD Button: Press to freeze the current reading on the display. Press again to release.
  • Backlight/Flashlight Button: Press briefly to turn on/off the display backlight. Press and hold to turn on/off the flashlight. The backlight typically turns off automatically after about 30 seconds to save power.
  • FUNC/Hz Button: Used to switch between different functions within a single rotary switch position (e.g., AC/DC current, frequency/duty cycle, diode/continuity).

6. Maintenance

6.1. Cleaning

Wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Keep the display clean and dry.

6.2. Battery Replacement

When the low battery indicator appears on the display, replace the batteries as described in Section 4.2. Always use new 1.5V AAA batteries.

6.3. Fuse Replacement

The multimeter is equipped with internal fuses for protection. If the current measurement function stops working, the fuse may need replacement. Fuse replacement should only be performed by qualified personnel. Refer to the specifications for fuse ratings (e.g., 10A FUSED, 600mA FUSED).

6.4. Storage

If the multimeter is not to be used for an extended period, remove the batteries to prevent leakage and corrosion. Store the device in a cool, dry place away from direct sunlight.

7. Troubleshooting

  • Multimeter not powering on: Check battery installation and ensure batteries are not depleted.
  • Inaccurate readings: Ensure test leads are properly connected, the correct function is selected, and the battery level is sufficient.
  • Speaker barely audible during continuity test: This may indicate a manufacturing variation. If it significantly impacts usability, contact customer support.
  • Backlight turns off too quickly: The backlight has an automatic shut-off feature (approx. 30 seconds) to conserve battery. This is normal operation and typically not user-adjustable for continuous on.
  • Cannot measure current/amperes: Ensure the test leads are connected to the correct current jacks (VΩmA or 10A FUSED) and the rotary switch is set to an appropriate current range. Verify the fuse is intact.
  • NCV not detecting wiring in walls accurately: The NCV function is for general detection of AC voltage presence and may have varying sensitivity depending on wall materials and distance. It is not a precise wire tracer.
  • Multimeter arrived defective: If the unit is not working upon arrival, contact the seller immediately for assistance.

8. Specifications

FeatureSpecification
Brand NameMESTEK
Model NumberDM90A (also DM90E, DM90S)
Operating ModeAuto Range (DM90A, DM90S), Manual Range (DM90E)
Display TypeDigital Display (LCD)
Maximum Display Number6000 counts
DC Voltage Range60mV/600mV/6V/60V/600V
AC Voltage Range60mV/600mV/6V/60V/600V
DC Current Range600uA/6000uA/60mA/600mA/10A
AC Current Range600uA/6000uA/60mA/600mA/10A
Resistance Range600Ω~ 60MΩ
Capacitance Range9.999mF~999.9uF
Measuring Inductance RangeN/A
Operating Temperature0 - 40 ℃
Dimensions170*120*60mm
WeightAbout 186g
Operational Power1.5V*3 AAA battery (not included)
Automatic Power-off Time15 minutes
Maximum Voltage Allowed600V DC or 600V AC (RMS)
Operation HeightMaximum 2000m
Overload ProtectionFull measuring range overload protection
CertificationsCE, RoHS

9. User Tips

  • Initial Check: Upon receiving your multimeter, perform a quick check of basic functions (e.g., continuity, voltage) to ensure it's working correctly. Some users have reported receiving defective units.
  • Battery Life: The automatic power-off feature after 15 minutes helps conserve battery life. The backlight also has an auto-off feature.
  • Continuity Test Speed: The continuity test is generally fast, typically responding within 2-3 seconds if the contact on the probes is good.
  • Capacitance Measurement: The multimeter can measure capacitance up to 9.999mF. While it can measure capacitors in-circuit, accuracy may be reduced due to other components on the board.
  • Compact Size: Many users appreciate the compact and portable design of this multimeter.
  • Temperature Probe (DM90A): The DM90A model includes a temperature probe, which is a useful addition for specific applications.

10. Warranty and Support

For warranty information, please refer to the certificate/warranty card included in your product package. If you encounter any issues or require technical assistance, please contact the MESTEK Official Store or your point of purchase for support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.